    Low Temperature Freezer DW-40FW110 Operation Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.7.16...
  • Page 2: Safe Notice

     If happen the questions which not mentioned in the manual, please contact MRC or agent ,and ask the right way to slove.  The better to use the MRC fittings, If the customers use other’s spare parts, MRC will be not responsible for the bad effect. But the customers can apply for MRC ...
  • Page 3: Schematic Picture And Description

    1.Schematic Picture and Description Handle lock Door body body Control panel P1:The structure photo Series of Ultra-low temperature freezer is designed to store materials under very low temperature condition for hospital, epidemic station, blood bank, research institute, university, biological pharmaceutical industry and gene engineering, etc. The internal temperature in cabinet can be easily adjusted through the keys in control panel.
  • Page 4: Pre-Installation

    2.Pre-Installation 2.1 Convey  Pick up the unit from the bottom of tank and a slant plane within 45° is acceptable. All transportation should be carefully.  Don’t catch the door body or ostium  Don’t allow to convert, flatwise, extrusion the freezer. ...
  • Page 5: Operation Direction

    3 Operation Direction First operation Advise to use the warm water and little scour to clean the freezer,and use the water to clean,then dry it. Set the freezer temperature as -26 ,after 30minutes,The freezer temperaure descend obviously,it mean the refrigeration system is normal,test is ok.(first use please set as -20 ,waiting the freezer closed ,then set as -26 ) To put the goods in the freezer after the temperature drop.
  • Page 6: Defrost ●Unused ● Maintenance

    temperature higher than setting temperature + return difference temperature,The replay will start refrigeration  Sensor failure alarm: When sensor plough,LED glittering and show “E1”,Alarm with buzzer.; When sensor short curcuit, LED glittering and show “E2”,Alarm with buzzer.  Exceed temperature range alarm: When sensor temperature more than+99 or less than -50 ,...
  • Page 7 Some unexpected failures may arise during running. Please pay attention to the running status of your freezer. If any exceptional case arises, please check and solve it DW-40FW110 according to the following introductions. If the problem is not solved well, please contact our service center for details.
  • Page 8 5. The mainly function 5.1 The mainly technical parameter Model DW-40FW110 Climatic type The facility safe types I Kind B Type Storing temperature -10~-25 Valid capacity(L) Rating vlotage(V~) Rating frequency(HZ) Input power(W) Refrigerant R134a Size(depth×width×height) (mm) 549*549*845 The encasement list...