  • Page 1 HD IR Waterproof Fixed Network Camera Quick Start Guide Version 1.0.1...
  • Page 2 Welcome Thank you for purchasing our network camera! This quick start guide is designed to be a reference tool for your system. Please keep this start guide well for future reference. Please open the accessory bag to check the items one by one in accordance with the list below. Contact your local retailer ASAP if something is missing or damaged in the bag.
  • Page 3 Thunder-proof device is recommended to be adopted to better prevent thunder. The grounding studs of the product are recommended to be grounded to further enhance the reliability of the camera. 6. Daily Maintenance Please shut down the device and then unplug the power cable before you begin daily maintenance work.
  • Page 4: Table Of Contents

    Table of Contents Structure ........................1 Multiple-function Combination Cable..............1 Framework and Dimension ................2 Bidirectional talk ....................3 1.3.1 Device-end to PC-end................. 3 1.3.2 PC-end to the Device-end ................3 Alarm Setup ...................... 4 1.4.1 Alarm IN/OUT Connection ................4 Device Installation ......................
  • Page 5: Structure

    1 Structure 1.1 Multiple-function Combination Cable You can refer to the following figure for multiple-function combination cable information. See Figure 1-1. Figure 1-1 Multiple-function combination cable Please refer to the following sheet for detailed information. Port Name Function Connection Note Video Output analog video signal.
  • Page 6: Framework And Dimension

    Please refer to the follow sheet for detailed pin information. Port Name Name Note ALARM_COM Alarm output public port. Alarm output port. It is to output the alarm signal to the alarm device. ALARM_NO NO: normal open alarm output port. I/O Port Alarm input port 1.
  • Page 7: Bidirectional Talk

    Figure 1-3 Dimension illustration 2 1.3 Bidirectional talk 1.3.1 Device-end to PC-end Device Connection Step 1: Please connect the speaker or the MIC to the audio input port of the device. Step 2: Then connect the earphone to the audio output port of the PC. Step 3: Login the Web and then click the Talk button to enable the bidirectional talk function.
  • Page 8: Alarm Setup

    At the PC-end, speak via the speaker or MIC, and then you can get the audio from the earphone or sound box at the device-end. 1.4 Alarm Setup The alarm interface is shown as in Figure 1-4. Figure 1-4 Alarm Please follow the steps listed below for local alarm input and output connection.
  • Page 9 Figure 1-5 Alarm input Please refer to the following figure for alarm output information. See Figure 1-6. Port ALARM_COM and Port ALARM_NO composes an on-off button to provide the alarm output. If the type is NO, this button is normal open. The button becomes off when there is an alarm output.
  • Page 10: Device Installation

    2 Device Installation Important Please make sure the installation surface can min support the 3X weight of the camera and the bracket. Please follow the steps listed below to install the device. Please refer to Figure 2-1 for reference.  Please line up the installation holes of the bottom of the device to the installation holes in the front part of the bracket.
  • Page 11: Quick Configuration Tool

    3 Quick Configuration Tool 3.1 Overview Quick configuration tool can search current IP address, modify IP address. At the same time, you can use it to upgrade the device. Please note the tool only applies to the IP addresses in the same segment. 3.2 Operation Double click the “ConfigTools.exe”...
  • Page 12 If you want to modify the device IP address without logging in the device web interface, you can go to the configuration tool main interface to set. In the configuration tool search interface (Figure 3-1), please select a device IP address and then double click it to open the login interface.
  • Page 13: Web Operation

    4 Web Operation This series network camera product supports the Web access and management via PC. Web includes several modules: monitor channel preview, system configuration, alarm and etc. 4.1 Network Connection Please follow the steps listed below for network connection. ...
  • Page 14 Figure 4-2 Web login After you successfully logged in, please install WEB plug-in unit. Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction. See Figure 4-3. Figure 4-3 Web monitoring window...
  • Page 15: Appendix Toxic Or Hazardous Materials Or Elements

    Appendix Toxic or Hazardous Materials or Elements Component Name Toxic or Hazardous Materials or Elements Cr VI PBDE ○ ○ ○ ○ ○ ○ Circuit Board Component ○ ○ ○ ○ ○ ○ Device Construction Material ○ ○ ○ ○ ○...