Phistek ZE6000 User Manual And Installation Manual

Av over ethernet gigabit adaptor

Advertisement

U
U
A
V
A
V
Warning!
It will cause malfunction if the AV Adaptor is operating with unspecified power supply
adaptor or incorrect power voltage. Do not expose this unit in the rain or moisture environment to
reduce the risk of fire or electric shock.
PRECAUTIONS
Do not use the "AV adaptor" and "Power supply Adaptor" near water.
The "AV adaptor" is featured with 75mm x 75mm and 100mm x 100mm VESA mount.
For easy and safe use, it is recommended to mount "AV adaptor" on the rear cover of monitor with
VESA mount.
The "AV Adaptor" should be operated by an Ethernet cable with standard RJ-45 connector on both
ends. One end to the "AV adaptor", the other end to host PC or server.
Never spill liquids on the "AV Adaptor".
Do not attempts to service "AV adaptor" yourself; opening or removing covers can degrade product
EMC and performance. Please refer all servicing to qualified service personnel.
For Wall mount "Power supply adaptor", wall socket shall be installed near the equipment and shall
be easily accessible.
s
e
r
M
a
n
u
a
l
s
e
r
M
a
n
u
a
l
O
v
e
r
E
t
h
e
O
v
e
r
E
t
h
e
M
o
d
e
M
o
d
e
/
I
n
s
t
a
l
l
a
t
i
o
/
I
n
s
t
a
l
l
a
t
i
r
n
e
t
G
i
g
a
b
i
r
n
e
t
G
i
g
a
b
i
l
N
o
.
Z
E
6
0
0
l
N
o
.
Z
E
6
0
0
n
G
u
i
d
e
o
n
G
u
i
d
e
t
A
d
a
p
t
o
r
t
A
d
a
p
t
o
r
0
0
1

Advertisement

Table of Contents
loading

Summary of Contents for Phistek ZE6000

  • Page 1 Warning! It will cause malfunction if the AV Adaptor is operating with unspecified power supply adaptor or incorrect power voltage. Do not expose this unit in the rain or moisture environment to reduce the risk of fire or electric shock. PRECAUTIONS Do not use the “AV adaptor”...
  • Page 2: Table Of Contents

    Install ZE6000 SMSC Driver--------------------------------------------------------------------------------- 7~8 Install EETI Touch Driver ------------------------------------------------------------------------------------ 9~12 III. Application-------- -------------------------------------------------------------------------------------------- 13~16 ZE6000 Mechanical Dimension and Input/ Output ports description ------------------- ------17 Output signals installation -------------------------------------------------------------------------------- 17 ZE6000 Adaptor installation ------------------------------------------------------------------ -------------18~19 VII. FCC Warning Statement ------------------------------------------------------------------------------------ 20 VIII.
  • Page 3: Introduction

    Simple plug and play Just attach a keyboard, mouse, and monitor to your ZE6000, and connect it to the host server. A station is set up easily and ready for use right away Easy and convenient installation Designed with VESA standard mounting on the adaptor box;...
  • Page 4: Check Accessories

    Check accessory Please make sure the entire accessory is included: User Guide & Driver CD DVI to VGA Dongle Power Adaptor...
  • Page 5: Driver Installation

    Drivers Installation The attached CD includes three drivers for installation: USB Server, SMSC Driver, Touch Driver (For Touch workstation only) Install Elite USB Server: Installation is automatically run as below:...
  • Page 6 After installation, screen will display as below, please press “Finish” Screen will then display as below, please choose to restart your computer.
  • Page 7: Install Ze6000 Smsc Driver

    Install SMSC Driver: Please press “I Accept”...
  • Page 8 Please select and confirm the “Language” Installation start as below, installation run automatically and completed with no additional message, please restart your computer to complete it.
  • Page 9: Install Eeti Touch Driver

    Install EETI Touch Driver (For Touch workstation only) Screen display as below, please click Next.
  • Page 10 Select the set up type, don’t tick the box if PS2 interface is not required, Click “Next> RS232 interface driver installed is default, please click Next>...
  • Page 11 You can select to do Touch screen calibration after system boot up or not Default setting is” None” Select to use Multi-Monitor system, then press Next>...
  • Page 12 Choose destination location, default folder location shown as below. Press Next> As Figure shown below, please press Next> to complete installation Note : For operating system other than Windows, please visit DisplayLink website: http://www.linuxfordevices.com/c/a/News/SMSC-releases-open-source-Linux-Ethernet-driver/...
  • Page 13: Application

    1. Set Up Procedures: 1.1 Required Hardware Ingredients The ZE6000 Zero-Client: typically available directly from PHISTEK. The host computer: should be scaled according to the usage scenarios 1) CPU - For connecting 6 users or more, we recommend on using Intel Core i7 CPU (or AMD FX-8).
  • Page 14 1) Install Elite Driver (See Page 5, Section II, 1.0) 2) Connect all ZE6000 Zero-Clients to Ethernet Switch. Connect monitors, keyboards, mice and sound devices to each ZE6000. 3) Launch the Network USB Setting Utility from its desktop shortcut. 4) This program will search for ZE6000 Zero-Clients:...
  • Page 15 6) Per each cluster, per each ZE6000 terminal: Click “Assign to this PC”: 7) Windows will identify and install USB sound driver. 8) A dialog will pop up – search for ZE6000 Zero Client software – click cancel. 9) Each client connection will be completed as below:...
  • Page 16 10) At this stage, you should be able to see all the assigned monitors in active Windows Desktop mode. 11) Start “ViewSpan Configuration” in the Task-Bar. Make sure to set all extra monitors as “Extended”...
  • Page 17: Ze6000 Mechanical Dimension And Input/ Output Ports Description

    IV. ZE6000 Mechanical Dimension and Input/ Output ports description: ⑨ 9. Reset Output signals installation:...
  • Page 18: Ze6000 Adaptor Installation

    VI. ZE6000 Adaptor installation: Type1: Type2: Type3:...
  • Page 19 Type 4:...
  • Page 20: Fcc Warning Statement

    FCC Warning Statement: FCC Class A Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 21: Product General Specification

    VII. Product General Specification ZE6000 AV over Ethernet Adaptor Power AC adaptor input AC100V~240V, 50~60Hz DC power output 12Vdc @1.5A LED indicators Yellow: to indicate power Adaptor attached Blue: to indicate device connected to Host PC Green: to indicate device identified...

Table of Contents