Horus Modules Latencies ............................... 37 Installing an additional Horus I/O Module ................... 38 Installing an additional Horus MADI Extension Module (MADM or MADS) ..........39 Installing the Merging PCIe Ethernet Controller Card NET-MSC-GBEX1 ........42 Horus recommended placement in Rack .................... 44 Horus power ON .............................
Page 3
How to provide Merging Support with a Horus debug dump file ..............90 Cannot access Horus remotely in Maintenance mode for Firmware update ........... 91 Firewall and Antivirus ..............................91 Symptom: Horus does not start up or will after a few minutes ..............92 www.merging.com/horus Page 3...
Page 4
Horus User Manual IMPORTANT SAFETY AND INSTALLATION INSTRUCTION SAVE THESE INSTRUCTIONS INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS WARNING – when using electric products, basic precautions should be followed, including the following: 1. Read all of the safety and installations instructions and explanation of graphic symbols before using the product.
Page 5
“as is” you, the purchaser, are assuming the entire risk of the results of using this Merging Technologies software. In no circumstances will Merging Technologies, its owners, directors, officers, employees or agents be liable to you for any consequential, incidental or indirect loss or damages including loss of time, loss of business, loss of profits, loss of data or similar resulting from the use of or inability to use the Merging Technologies hardware and or software or for any defect in the hardware software or documentation.
Test Report: Test report Ref No: 16'835 Issued Date: June 2012 by Montena EMC SA The CE label is affixed on the rear of left side of the Horus unit as per below : Date 12 June 2012 Claude Cellier President Merging Technologies S.A.
Horus Warranty Information * Replacing or adding a AD, DA or MADI module and adjusting the DA module dip switch (output) is permitted under the supervision of a Merging sales partner. Any other modification will void the Horus warranty. Contacting Merging www.merging.com...
Page 10
Horus User Manual www.merging.com/horus Page 10...
Horus User Manual Horus optional cards IOM-H-AD8D / AD8DP These remotely controlled Mic/Line Input cards have set a new benchmark in analog circuitry design, and provide additionally a Line level post Mic-pre “Direct Out” output. Available in models that work up to 192kHz (AD8D) and DXD/DSD256 (AD8DP) IOM-H-AD8D / AD8DP Key Features •...
Page 17
Horus User Manual IOM-H-AD8D/AD8DP Mic-Pre Analog Section Frequency response +0/-0.5 dB, Line 5 Hz - 75 kHz Frequency response +0/-2.0 dB, Line 2.5 Hz - 150 kHz Frequency response +0/-0.5 dB, Mic 10 Hz - 100 kHz Frequency response +0/-2.0 dB, Mic...
Page 18
Horus User Manual AD8D / AD8DP run 1 to run 8 Analog input 48V phantom Preamp Mic / Line pad power analog gain A/D converter Digital gain -11dB On / Off 0 to + 40dB Analog output Direct Out +18dBu...
Page 20
Horus User Manual Line Output Level calibration The DA8 and DA8P modules feature both hardware level settings and a software fine adjustment to align the Analog Output levels to whatever local/organization operational levels are mandated. On DA8/DA8P cards from run 7 upwards, the hardware level setting is done via software through the option “max output level”...
Page 21
Horus User Manual www.merging.com/horus Page 21...
Page 22
Horus User Manual DA8 / DA8P run 1 to run 6 Analog Output Level Analog Output Digital input Digital Selection Output Attenuation Roll Off Filter D/A converter Mute Relay +12dB/+15dB/ [0 .. -60dB] +18dB/+24dB DA8 / DA8P run 7 and above...
Page 23
Horus User Manual IOM-H-ADA8 These remotely controlled Mic/Line Input and Output cards have broken a new barrier in terms of compactness as well as ultra-low power consumption without compromising on the audio quality. These cards work at sampling rates up to 192 kHz Using those combined 8 channel Mic/Line In and Line Out cards allow the Hapi to be configured with up to 16 channels of Analog In/Out.
Page 24
Horus User Manual IOM-H-ADA8 Mic-Pre Analog Section Frequency response +0/-0.5 dB, Line 5 Hz - 75 kHz Frequency response +0/-2.0 dB, Line 2.5 Hz - 150 kHz Frequency response +0/-0.5 dB, Mic 10 Hz - 100 kHz Frequency response +0/-2.0 dB, Mic...
Page 25
Digilink Mini connectors. You can insert up to two modules in a device, meaning you can manage up to 128 Channels at a time. Note that, in Horus, the cards can only be mounted in Slot 3 and Slot 6.
Page 26
Horus User Manual In Pro Tools, the Clock source should be set to Internal for the device emulated by the IOM-H-PT64 module (HD MADI in the following example). www.merging.com/horus Page 26...
Page 27
Sync Source: The next setup is using Horus as the Master clock for all devices. In this case, the Clock Source must be set to the other device’s Word Clock. The Follow SR option in Setup -> Format must be enabled.
Page 28
Horus routing or preamps, it will just set the Input/Output Delays as seen above. When set to None, Pro Tools will see the module as an HD MADI, but Horus will use the minimum latency. Therefore, Delay Compensation will not be accurate on Pro Tools in this mode.
The ADA8 work at sample rates up to 192 kHz. HD Link with Pro Tools HD The PT Module allows the Horus to communicate with a Pro Tools HD card. With two modules in one interface, up to 128 channels can be recorded simultaneously.
Page 36
RAVENNA IP Audio Synchronization Audio is not the only information that can pass down the RAVENNA connection. Horus is also able to send sync (LTC) down the same wire to and from the Hapi unit. For more details refer to the RAVENNA network guide available on www.merging.com...
Horus User Manual REFS Menu (I/O & Sync) PreAmp Menu www.merging.com/horus Page 50...
Page 51
Horus User Manual Line Fader of 0 dB, means 0 dBFS for +24 dBu Analog signal level present at the Line input Line Fader of + 6 dB, means 0 dBFS for +18 dBu Analog signal level present at the Line input...
Page 52
Horus User Manual Zlo – Zhi Mic input impedance (only available for ADA8 & AD8D/AD8DP run 9 and above modules) 48V Phantom Disabled Enabled 2 kΩ 1.7 kΩ 13.6 kΩ 6.8 kΩ www.merging.com/horus Page 52...
Horus User Manual Formats Menu (Setup) Horus can be configured in DXD/DSD and in this mode the Horus can receive any audio data format stream and can generate DXD or DSD(64, 128 or 256) stream depending on the A/D audio data format chosen.
Horus User Manual Routing Menu (Setup) www.merging.com/horus Page 55...
Page 56
Horus User Manual Routing: Configuration Headphone - D/A - AES - MADI - PT Routing Output Source (similar) ADA N The ADA buttons, which become active if you have 1 or more ADA8 modules installed in the Hapi unit, give access to the Input controls.
Horus User Manual Modules Menu (Setup) Headphone A/D N ADA N The ADA buttons, which become active if you have 1 or more ADA8 modules installed in the Hapi unit, give access to the Input controls. D/A N PT 3/6...
Output Source: Shortcut to the Output Source Routing Page configuration Modules: A/D Sub-Menu Example: Setting a gain alignment of +10dB will make the Horus, Web Access or the Pyramix PreAmps control to be offset by a scaling of +10 dB. Module www.merging.com/horus...
Horus User Manual Modules: ADA Sub-Menu Mic Alignment: User can offset the Mic Gain Alignment scaling from a Range of 0dB to +12dB. Example: Setting a gain alignment of +10dB will make the Hapi, Web Access or the Pyramix PreAmps control to be offset by a scaling of +10 dB.
Horus User Manual Modules: PT Sub-Menu Emulation mode: Selection of the Hardware emulated in Pro Tools. Latency is adapted to the mode chosen, see detailed table in IOM-H-PT64 section. None mode is seen as an HD MADI in Pro Tools, but has the lowest latency.
Horus User Manual Modules: Loopback (hidden menu, available only for debug use) Transparency Check: This is a Debug Utility tool that verifies the bit transparency of the audio path www.merging.com/horus Page 63...
Horus User Manual Presets Menu (Setup) can be loaded (one at a time) Auto Save: If enabled the save configuration will happen at every 2 minutes. www.merging.com/horus Page 64...
Horus User Manual System (Setup): The Dark option will display a black Screen Saver, mainly used when Horus needs to be a discreet stage box. 75Ω for WCK: Sets 75Ω termination for the Wordclock Input. Terminations: 75Ω for Video: Sets 75Ω termination for the Video reference Input. Unless the...
Horus User Manual Horus Web Control access Installing and accessing the Horus Control interface remotely http://www.merging.com/products/horus/downloads www.merging.com/horus Page 68...
Page 69
Horus User Manual www.merging.com/horus Page 69...
Page 70
Horus User Manual www.merging.com/horus Page 70...
Page 71
Horus User Manual For other parameters, please refer to the PreAmps module description (above) www.merging.com/horus Page 71...
Page 75
Horus User Manual www.merging.com/horus Page 75...
Page 76
Horus User Manual www.merging.com/horus Page 76...
Page 77
Horus User Manual www.merging.com/horus Page 77...
Page 78
Horus User Manual www.merging.com/horus Page 78...
Page 79
Horus User Manual www.merging.com/horus Page 79...
Page 80
Horus User Manual How to use the IOM-H-PT64 module with Digidesign HDIO www.merging.com/horus Page 80...
Page 81
Horus User Manual Manage Mic PREs from Pro Tools MAC All details are available in the MergingVirtual Audio Device (formerly Core Audio Driver) Guide: http://www.merging.com/products/networked-audio/downloads www.merging.com/horus Page 81...
Page 82
Horus User Manual Pro Tools on PC Horus / Hapi http://www.tobias-erichsen.de/wp-content/uploads/2012/08/rtpMIDI_1_0_11_227.zip www.merging.com/horus Page 82...
Page 85
Horus User Manual http://www.merging.com/products/horus/downloads http://www.merging.com/products/horus/downloadshttp://www.merging.com/horus/download www.merging.com/horus Page 85...
Page 86
Horus User Manual Wrong maintenance version, must be >= 31” . Note: A Maintenance Mode update requires a shutdown of the Horus once the update completed. www.merging.com/horus Page 86...
Page 87
Horus User Manual Wrong maintenance version, must be >= 31”. This means that you must first install the latest Maintenance Firmware prior to updating to the latest Firmware Contact us at support@merging.com if your firmware update cannot be executed www.merging.com/horus...
Horus User Manual Horus troubleshooting Horus on screen Error Report "Primary Power Supply Failure"; "Secondary Power Supply Failure"; "Two Power Supplies Required" in case of more than 3 A/D are present "Temperature too high"; "Horus Application failure, please reboot" "Fan failure"...
Need help?
Do you have a question about the horus and is the answer not in the manual?
Questions and answers