Download Print this page

London Cool pyramid flame User Manual

Tower patio heater

Advertisement

Quick Links

Pyramid Flame Tower Patio Heater
WARNING!
Hazardous fire or explosion may result if instructions are
ignored.
It is the customer's responsibility to see that the patio heater
is properly assembled, installed and taken care of.
Failure to follow instructions in this manual could result in
bodily injury and/or property damage.
DO NOT OPERATE UNDER THE INFLUENZE OF
ALCOHOL OR DRUGS.
Precautions
Ensure the connection to the gas bottle has been
tightly secured with a spanner where necessary.
Leak test all connections after each bottle re-fill
Never check for leaks with a match or open flame
Do not store or use gasoline or other flammable
vapours and liquids in the vicinity of this or any
other appliance
Any LPG bottle not connected for use shall not be
stored in the vicinity of this or any other appliance
For your safety – if you smell gas
Turn off the gas supply at the bottle.
Extinguish all naked flames; do not operate any electrical
appliances.
Ventilate the area.
Check for leaks as detailed in this manual.
If odour persists, contact London Cool immediately on 0800
440 444.
FOR OUTDOOR USE ONLY
The use of this appliance in enclosed areas can be
dangerous and is PROHIBITED.
Using this product in an enclosed area may cause injury,
death or property damage.
Read the instructions before using this appliance. This
appliance must be installed in accordance with instructions
and local regulations.
WARNING!
For use outdoors or in amply ventilated areas
An amply ventilated area must have a minimum of
25% of the surface area open
The surface area is the sum of the walls surface
Do not use this heater in an explosive atmosphere.
Keep the heater away from areas where gasoline or other
flammable liquids or vapours are stored.
Prior to use, check for damaged parts such as hoses,
regulators, pilot or burner.
Do not move the heater when in operation.
Shut off the valve at the gas cylinder before moving the
appliance.
Disconnect the LPG bottle before moving the heater.
Do not attempt to alter the unit in any manner, e.g. using the
heater without the top canopy reflector or radiant screen.
The appliance shall not be used in basements or above
ground level.
It must always be placed on a solid level surface.
Always ensure there is ample fresh air ventilation.
Never replace or substitute the regulator with any other
regulator other than the factory suggested replacement.
Do not clean the heaters with cleaners that are combustible
or corrosive.
Do not paint radiant screen, control panel or top canopy
reflector.
All leak tests should be done with a soapy solution. NEVER
USE AN OPEN FLAME TO CHECK FOR LEAKS.
The LPG gas bottle valve and regulator should be turned off
when the heater is not in use.
Do not use when it is raining, always be careful not to let any
liquid splash the glass tube when the heater is working.
Keep children away from the heater, always be careful not to
knock over the heater which will break the glass tube and
may cause injury.
The following clearance distances are required for safe
operation when using this heater. It is important you keep
these distances from combustible materials: minimum
clearance to adjacent combustibles: from top: 61cm, from
sides: 60cm.
Check the heater immediately if any of the following exists:
1. The smell of gas
2. The heater does not reach temperature
3. The burner makes a popping noise during use
(a slight popping noise is normal when the
burner is extinguished after use)
If you smell gas, turn off the valve immediately. If the
smell persists, contact London Cool immediately.
The propane hose with regulator assembly shall be
located out of the pathway where people may trip over

Advertisement

loading

Summary of Contents for London Cool pyramid flame

  • Page 1 Check for leaks as detailed in this manual. knock over the heater which will break the glass tube and may cause injury. If odour persists, contact London Cool immediately on 0800 440 444. The following clearance distances are required for safe operation when using this heater.
  • Page 2: Installation

    Replacement pressure regulator and hose to avoid clothes burning or igniting. assembly must be those specified. Replacement parts may be obtained from the manufacturer or London Cool. Young children should be carefully supervised when they are in the area of the heater.
  • Page 3: Parts List

    required if necessary. It is imperative that control compartment, burners and circulating air passengers of the heater be kept clean Connecti 10. In case of violent wind particular attention must be ng tube taken against tilting of the appliance Upper protection Parts list guard...
  • Page 4 Attach the protection guards (11), (13) onto the upper frame by putting its hooks Fix the reflector (10) onto the into the holes of the frame. damper (9) by screws (17). Connect two guards with the connecting tube (12), fix the guards with the fixing brackets (14).
  • Page 5: Operation

    Operation Lighting instructions Preparation Check and ensure that an AA battery is inside the ignition chamber and has power. Ensure the anode (+) faces You will need to purchase a propane gas bottle designed to outside. be used with the regulator purchased or supplied. For correct operation of the gas system follow the instructions supplied with the regulator supplied or purchased.
  • Page 6: Maintenance And Storage

    carbon deposits develop. Always be careful when cleaning the glass tube. Storage Between uses:  Turn the control knob to the ‘OFF’ position  Turn LPG bottle to ‘OFF’ position  Store heater upright in an area sheltered away from weather conditions (such as rain, sleet, hail and Maintenance and storage snow)
  • Page 7 Fuel bottle is Pressure is low nearly empty Remove, clean Orifice blocked and replace Control valve not Turn valve to ON Burner will not light Thermocouple Replace faulty thermocouple Pilot light Place pilot light in assembly out of correct position alignment or not in and retry correct location...