ALLIANCE ALLWH3.2kW Technical Manual

ALLIANCE ALLWH3.2kW Technical Manual

Cycle-heating domestic heat pump water heater

Advertisement

AA –HP410-2011-02
Alliance Cycle-Heating Domestic
Alliance reserves the right to discontinue, or change at any time, specifications or designs without notices
and without incurring obligations.
Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual
Heat Pump Water Heater
R410
- Technical Manual

Applicable Models:

ALLWH3.2kW R410
ALLWH5.0kW R410
ALLWH7.2kW R410
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALLWH3.2kW and is the answer not in the manual?

Questions and answers

Summary of Contents for ALLIANCE ALLWH3.2kW

  • Page 1: Applicable Models

    Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual Alliance Cycle-Heating Domestic Heat Pump Water Heater R410 - Technical Manual Applicable Models: ALLWH3.2kW R410 ALLWH5.0kW R410 ALLWH7.2kW R410 Alliance reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.
  • Page 2: Table Of Contents

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual Contents Part 1 General Information ............... 3 1. Model Names of Outdoor Units ................4 2. External Appearance .................... 4 3. Nomenclature......................5 4. Features ........................ 6 Part 2 Outdoor units .................. 7 1.
  • Page 3: Part 1 General Information

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual Part 1 General Information 1. Model Names of Outdoor Units ........4 2. External Appearance ............4 3. Nomenclature ..............5 4. Features ................6...
  • Page 4: Model Names Of Outdoor Units

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual Model Names of Outdoor Units Outdoor Units Model name Dimension (mm) Net/Gross weight (kg) Power supply Width: 790 ALLWH3.2 KW Height: 736 54/57 220~240V-1ph-50Hz Depth:260 Width: 790 ALLWH5.0 KW...
  • Page 5: Nomenclature

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual Nomenclature Household water heating unit 9 10 Design code Refrigerant code Water supply pump lift code Other functions code Power supply specification code Heating mode code Water tank volume, unit: L...
  • Page 6: Features

    The unit uses heat pump principle, which absorbs heat from outdoor air and produces hot water. Thermal efficiency can be approximately 4.0. 4.8 All-weather running. Designed to operate between temperatures ranging from -7 to 43℃, the Alliance heat pump heats at night and during periods of overcast sky, rain and snow. 4.9 Convenient installation and maintenance The quadrate type is highly compact and can be easily installed in narrow areas 4.10 Wilo water pump built into the main unit.
  • Page 7: Part 2 Outdoor Units

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual Part 2 Outdoor units 1. Specifications ..............8 2. Relationship between Outdoor Ambient Temperature and Unit Capacity ........10 3. Relationship between Outdoor Ambient Temperature and COP ........... 12 4.
  • Page 8: Specifications

    AA –HP410-2011-02 Alliance Cycle-Heating Household Heat Pump Water Heater Technical Manual 1. Specifications Model ALLWH3.2 KW ALLWH5.0 KW ALLWH7.2 KW Power supply Ph-V-hz 1-220-50 1-220~240-50 1-220-50 Capacity Water Input 1.11 0.81 Heating Rated current Max. input consumption 2.55 1.55 1.85 Max.
  • Page 9 AA –HP410-2011-02 Alliance Cycle-Heating Household Heat Pump Water Heater Technical Manual Outdoor air flow m3/h 3200 2000 2000 Outdoor noise level dB(A) Dimension 790×736×260 790×736×260 (W*H*D) 840×940×324 Outdoor Packing 905×807×355 905×807×355 unit (W*H*D) 965×1009×395 Net/Gross 54/57 62/66 weight 81/86.5 Refrigerant type/Quantity R410A/1.3...
  • Page 10: Relationship Between Outdoor Ambient Temperature And Unit Capacity

    AA –HP410-2011-02 Alliance Cycle-Heating Household Heat Pump Water Heater Technical Manual 2. Relationship between Outdoor Ambient Temperature and Unit Capacity Heat Pump Models: ALLWH3.2 KW ALLWH5.0 KW...
  • Page 11 AA –HP410-2011-02 Alliance Cycle-Heating Household Heat Pump Water Heater Technical Manual ALLWH7.2 KW...
  • Page 12: Relationship Between Outdoor Ambient Temperature And Cop

    AA –HP410-2011-02 Alliance Cycle-Heating Household Heat Pump Water Heater Technical Manual 3. Relationship between Outdoor Ambient Temperature and COP Heat Pump Models: ALLWH3.2 KW ALLWH5.0 KW...
  • Page 13 AA –HP410-2011-02 Alliance Cycle-Heating Household Heat Pump Water Heater Technical Manual ALLWH7.2 KW...
  • Page 14: Relationship Between Outdoor Ambient Temperature And Outlet Water Temperature

    AA –HP410-2011-02 Alliance Cycle-Heating Household Heat Pump Water Heater Technical Manual 4. Relationship between Outdoor Ambient Temperature and Outlet Water Temperature Note: The unit outlet water temperature is under full-automatic control and the water tank is the pressure type. When hot water is being drawn off, cold water will enter the water tank, thus decreasing the temperature.
  • Page 15: Main Unit Foundation Bolt Dimensions

    AA –HP410-2011-02 Alliance Cycle-Heating Household Heat Pump Water Heater Technical Manual 5. Main Unit Foundation Bolt Dimensions × Throu gh ho le (12 22 li nea r hole ) ODEL ALLWH3.2 KW ALLWH5.0 KW ALLWH7.2 KW 6. Service Space...
  • Page 16: Wiring Diagrams

    AA –HP410-2011-02 Alliance Cycle-Heating Household Heat Pump Water Heater Technical Manual 7. Wiring Diagrams ALLWH3.2 ALLWH3.2KW ALLWH5.0 KW ALLWH7.2 KW 1.5HP ALLWH5.0 ALLWH7.2...
  • Page 17: Exploded View

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 8. Exploded View ALLWH3.2 KW & ALLWH5.0 KW 30 30.1 32 32.1 32.2 32.3 32.4 32.5 32.6 6 6.1 6.2...
  • Page 18 AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 32.6 32.3 32.2 32.1 32.4 32.5 30.1 Part Name Quantity Part Name Quantity Rear right clapboard ass'y Temp.sensor ass'y Front panel Compressor electric heater Top cover Discharge temp sensor ass'y...
  • Page 19 AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual ALLWH7.2kW...
  • Page 20 AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual External overload protection Model selection 202090590098 device of compressor (Set before out from factory) 1.5HP RSJF-35/CN1-A RSJF-50/CN1-A 0.8HP RSJF-65/CN1-A RSJF-28/CN1-A White FOR CE C N24 CN25 CN 10 CN 9...
  • Page 21: Pcb Explanation

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 9. PCB explantation...
  • Page 22: Part 3 Installation

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual Part 3 Installation 1. Precautions ..............23 2. Installation information ..........24 3. Accessories ..............25 4. System schematic diagram of whole unit ……………..26 5. Electrical wiring ............267 6.
  • Page 23: Precautions

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 1. Precautions Be sure to conform to local, national and international laws and regulations. Read "PRECAUTIONS" carefully before installation. They include important safety items. Keep this manual with the owner's manual for future reference.
  • Page 24: Installation Information

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual The water heater must be earthed. Do not connect the earthing wire to gas or water pipes, lightning rod or a telephone earthing wire. Incomplete earthing may result in electric shocks.
  • Page 25: Accessories

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 3. Accessories Please check whether all the following fittings are included. If any are missing, be sure to obtain them before proceeding with installation. Name Application 1. Installation and User Manual ——...
  • Page 26: System Diagram Of The Whole Unit

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 3. System schematic diagram of whole unit dels: ALLWH3.2 KW ALLWH5.0 KW ALLWH7.2 KW...
  • Page 27: Electrical Wiring

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 5. Electrical wiring 5.1 Attention • • • • The water heater is to be connected correctly in terms of power supply and rated power voltage. • • • •...
  • Page 28 AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 5.4 Power supply wiring. A. Power supply equipment application Power supply equipment Leakage (with leakage protector) protector Earthing Manual switch Earthing Earthing Junction Earthing Earthing Earthing Note: Although there is a leakage protector in the electric control box of the unit, for reasons of additional security it is required that a leakage protector be installed in the external electric control box of the unit according to the above diagram.
  • Page 29 AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 5.5 Electrical connection diagram. Electrical Wiring diagram for Models :ALLWH3.2 KW, ALLWH5.0 KW, ALLWH7.2 KW...
  • Page 30: Outdoor Unit Installation

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 6. Outdoor Unit Installation Installation space requirement Ensure there is sufficient space for the maintenance of outdoor unit A distance of no less than 200mm should be maintained between the bottom of the outdoor unit and the ground or bracket for the installation of the duct pipe.
  • Page 31: Water Pipe Installation

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 7. Water Pipe Installation 7.1 Installation material preparative Installation Materials Name Specification and Usage Metal, non-metal composite pipes; PPR pipe, Water pipe, flexible joint Decided by the project needs.
  • Page 32 AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 7.3 Connecting diagram of the water heater Name Connective pipe specification Circulating water outlet of main unit DN20 Circulating water inlet of main unit DN20 Circulating water outlet of water tank...
  • Page 33: Part 4 Trial Operation

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual Part 4 Trial Operation 1. Checklist before the trial operation ......34 2. Water Tank water resupplying and Water Pipe and Pump Air Exhaust (Artesian Pressure Water Tank) ..35 3.
  • Page 34: Confirmation Before The Trial Operation

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 1. Checklist before the trial operation Ensure that: 1.1 The entire installation is complete. 1.2 Water heater is installed correctly. 1.3 Pipelines and wiring are correct. 1.4 All accessories are installed correctly.
  • Page 35: Water Tank Water Resupplying And Water Pipe And Pump Air Exhaust (Artesian Pressure Water Tank)

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 2. Water Tank water resupplying and Water Pipe and Pump Air Exhaust (Artesian Pressure Water Tank) Open the tap water pipe valve to charge the water tank Open the water valve and all the faucets until the water Air exhaust flows out and there is no air flow.
  • Page 36: Wire Controller All Remote Water

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 3. Wire Controller ALL REMOTE WATER/BE Page up Mode Clock Spot Check Timing on Temp. set Down Timing off Page down Reset Lock Alliance Central Heat Pump Water Heater Function: •...
  • Page 37: Trial Operation Check

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 5. Trial Operation Check Control the water heater operation by wired controller (from accessory) and check the following items in accordance with the User’s Manual (If any error, please eliminate it according to the error code explanation and analysis at the end of this manual.):...
  • Page 38: Error Code Explanation And Analysis

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 7. Error Code Explanation and Analysis Code Code Explanation Cause Analysis Solution Communication failure between the main unit Connect the main unit with the A, B, P, Q and the wired controller and E lines of the wired controller correctly.
  • Page 39: Spot Check

    AA –HP410-2011-02 Alliance Cycle-Heating Domestic Heat Pump Water Heater Technical Manual 8. Spot Check Main Control Board Spot Check Normal Operation Wind T3 Temp. T4 Temp. T2 Temp. Display Mode Speed Compressor Last error --" TS Temp. T6 Temp. T5 Temp.

This manual is also suitable for:

Allwh5.0kwAllwh7.2kw

Table of Contents

Save PDF