  • Page 1: Installation Guide

    Perle Advanced Powered Ethernet Extenders Installation Guide 10/100 10/100/1000(Gigabit) eXP-xS110L eXP-xS1110L eXP-xS110E eXP-xS1110PE eXP-xS1110E Part# 5500332-11...
  • Page 2 2-wire twisted pair telephone wire or coax cable using VDSL2 technology for extended distances. The Perle Advanced Power Ethernet Extenders are available in L and E models such as the eXP-1S110E and the eXP-1S110L. In order to use the advanced power functions, an L model must always be used in conjunction with an E model.
  • Page 3 Installation Front Panel View Back Panel View...
  • Page 4: Installation

    Installation These are the steps required to configure a pair of Advanced Power Ethernet Extenders. 1. Set the Dip switches on each Ethernet Extender (if needed). See Bank 1 - Dip Switches for more information. 2. Set Power Sourcing Jumpers (If needed) (E and PE models only).
  • Page 5: Dip Switches

    Dip Switches The default Dip Switch settings (all UP) will work for most installations, however it is recommended that one Ethernet Extender should be configured for Auto Local mode (Auto CO) and the other for Remote mode (CPE). The Dip switches are accessible through an opening on the back of the unit.
  • Page 6 3 NOTE: The actual distance and rates may vary depending on the environment and type/gauge of wire used. For information on hardware specifications, range and reach see the Perle website at www.perle.com. Symmetric/Asymmetric (Switch 3)
  • Page 7 Asymmetric: Set this switch to Asymmetric if your network data needs are primarily for downloads. (Larger bandwidths will be available in the direction of the Remote/CPE Ethernet Extender). Signal to Noise Ratio (Switch 4) Switch Position Mode Up (default) Down This switch is used to configure the Signal to Noise Ratio Margin (SNR).
  • Page 8 Ethernet AutoNeg allows you to control of the Ethernet communications parameters on Ethernet Port 1. If the Ethernet device to be connected on port 1 cannot operate with conventional Ethernet Auto negotiation, then switches 7 and 8 can be used to specify these parameters. Ethernet AutoNeg On: When enabled, the Ethernet Extender will Auto-negotiate Ethernet Link parameters with its link partner.
  • Page 9: Link Pass-Through

    connection to its remote connection. A loss of link on the Ethernet interface can occur without affecting the remote connection. Link Pass-Through: In this mode, the Ethernet Extender will pass the state of the Ethernet interface across the Line connection to its peer. If link is lost on the Ethernet connection, then the Ethernet connection on the remote Ethernet Extender will be brought down.
  • Page 10 Interlink Fault Feedback The 10/100 or 10/100/1000 ports (LNK) on each of the links will be turned off if the VDSL link is broken. PSE Power (Switch 3, 4) (applies to port 1 on eXP- xS110E/1110/P/E models)) These switches are used on the E and PE models to indicate the type of device detection required when connecting a PD to port 1 of the Ethernet Extender.
  • Page 11 Disabled: Power is maintained to the PD. POE Power from PSE In order to power an L model Ethernet Extender using PoE, Port 1 of the Ethernet Extender, you will need to be connected to a compliant PSE device. The Ethernet Extender can be strapped as either a Class 0 (PoE) or a Class 4 (PoE+) type PD device using Jumper (J4).
  • Page 12: Jumper Settings

    disable power, doing so may help achieve longer data connection distances. NOTE: The Local and Remote Ethernet Extenders must be strapped the same. Jumper Settings Providing PoE Power to a PD NOTE: The factory settings will work for most installations. Compliant PD’s will detect and operate with the default PoE option.
  • Page 13: Connecting To The Ethernet Ports

    NOTE: Refer to the Technical Specifications section at the back of this guide for pin/cabling requirements. Powering with supplied Power Adapter • Connect the Perle supplied power adapter to the Ethernet Extender and an appropriate AC power source. • Check that the PWR LED light is lit.
  • Page 14 • Strip insulator sheathing from both wires 5mm (3/16th inch) to expose the copper conductor wire. • Loosen the terminal block screws and connect Positive (+) wire to the left terminal. Connect the Negative (-) wire to the right terminal. Tighten Terminal screws (0.22Nm-0.25Nm torque).
  • Page 15: Operation

    Operation Status LEDs Perle Ethernet Extenders have multicolor LEDs located on the front panel of each unit. On – Power good. On (solid Green) – PSE Active – Blinking (slow) – Loopback Supplying power over the mode. Ethernet. Blinking (fast) – Hardware On (solid Yellow) –...
  • Page 16: Troubleshooting

    Troubleshooting If unable to get full connectivity with all Dip switches in the UP position, this procedure is recommended for troubleshooting. Check Ethernet Connection • Ensure Link mode (SW9) and Interlink Fault Feedback (SW10) are set to the UP position on both Ethernet Extenders. •...
  • Page 17: Technical Specifications

    (includes XT Models) (includes XT Models) Barrel Connector 23-57VDC 46-57VDC Terminal Connector PoE Output 46-57VDC (will vary by model: See Max 0.65A www.perle.com (when using DC 57V details). input) From PoE Input 37-57VDC Max 0.65A VDSL Output 57VDC Max 0.65A...
  • Page 18 Storage Humidity 5% to 95% non- 5% to 95% non- condensing condensing Operating Altitude Up to 3,048 m Up to 3,048 m (10,000 ft) (10,000 ft) Ethernet Copper Cabling Requirements: • Category 5e, 6, 7 UTP or STP • 24-22 AWG •...
  • Page 19: Ethernet Interfaces

    Ethernet Interfaces PoE Option RJ-45 Alternative Alternative Legacy positive positive negative positive negative positive negative negative negative positive negative positive...
  • Page 20: Warranty Registration

    Class ll, double insulated power supply/adapter. Warranty / Registration Perle’s standard Lifetime Warranty provides customers with return to factory repairs for Perle products that fail under the conditions of the warranty coverage. Details can be found at: http://www.perle.com/support_services/warranty.shtml...