DMR-EX75EG / DMR-EX75EC / DMR-EX75EB / DMR-EX85EG / DMR-EX85EB
Mode name
ATP re-execution
Progressive initialization The progressive setting is initialized to
8.1.3.
SERVICE MODES AT A GLANCE
Service mode setting: While the power is off, press [REC], [CH UP] and [OPEN/CLOSE] simultaneously for five seconds.
Mode name
Release Items
Error Code Display
ROM Version Display
White Picture Output
Item
Description
Re-execute ATP.
Interlace.
Item
Description
Item of Service Mode executing is cancelled.
Last Error Code of U/H/F held by Timer is
displayed on FL.
*Details are described in "Self-Diagnosis
Functions".
1. Region code
(displayed for 5 sec.)
2. Main firm version
(displayed for 5 sec.)
3. Timer firm version
(displayed for 5 sec.)
4. Drive firm version
(displayed for 5 sec.)
5. ROM correction version
(left displayed)
White picture is output as component Output
from AV Decoder.
*White picture
(Saturation rate : 100%)
*It is enable to switch Interlace/Progressive
by "I/P switch: [1] [4]"
FL display
Display at ATP executing.
The display before execution
leaves.
FL display
If any error history dose not exist,
[F00] is displayed.
1.
2.
3.
4.
5.
'' '' are version displays.
*Initial mode is "Interlace".
Switch Interlace/Progressive
22
Key operation
Front Key
When the power is on (E-E mode),
press [CH UP] and [CH DOWN]
simultaneously for 5 seconds.
When the power is on (E-E mode),
press [STOP] and [PLAY]
simultaneously for 5 seconds.
Key operation
(Remote controller key)
Press [0] [0] or [Return] in service
mode.
Press [0] [1] in service mode
Press [0] [2] in service mode
Press [1] [1] in service mode.
Press [1] [4] in White Picture
Output mode.
*I/P are switched alternately.