    INSTALLATION MANUAL SITTING GAS CONNECTION ADJUSTMENT OF THE HOB BURNER LAG 024 R & LAG 020 R: Cooking surface option with 2 burners located ELECTRICAL POWER CONNECTION on left or right of central hob (depending on model). WIRING DIAGRAM ►2 burners of different size and power (Voir B, C, D : table 1 appendix 0).
  • Page 3: Installation Manual

    Hob top option «LAG 010 UR» «LAG 020 R» «LAG 024 R» INSTALLER’S MANUAL Appliances must be installed in a workmanlike manner in accordance with the instructions in this manual and locally applicable regulations. This manual should be handed over to the user after installation.
  • Page 4: Sitting

    SITTING GAS CONNECTION CAUTION: Natural gas: Since 1st July 1997, an automatic shut-off valve must be fitted to all new installation or whenever an • The buyer agrees to install the appliance in accordance with recognised best practices and the existing shut-off valve is replaced.
  • Page 5: Adjustment Of The Hob Burner

    ADJUSTMENT OF THE HOB BURNER ADJUSTMENT OF THE HOB BURNER Lacanche’s gas appliances are delivered fully adjusted in compliance with relevant regulations and ADJUSTMENT OF THE FLOW RATE: for use with the particular gas supply (type, pressure) stated in the purchase order and indicated in The adjustment of the low flame gas delivery rate is carried out with the the appliance’s nameplate.
  • Page 6 ADJUSTMENT OF THE HOB BURNER PRIMARY AIR ADJUSTMENT: The adjustment of the primary air (air-gas mixture) is done by adjusting the air ring located in the base of the burner, under the table. The mixture is correct when the flame is stable with blue cones. A soft flame with yellow tips is the result of lack of air.
  • Page 7: Electrical Power Connection

    ELECTRICAL POWER CONNECTION WIRING DIAGRAM The installation must be carried out in accordance with recognised best practices, the instructions given in this manual and the regulations in force in the country of installation. The means for disconnection must be provided in fixed installations in accordance with all relevant regulations.
  • Page 8: Instruction Manual

    Hob top option «LAG 010 UR» «LAG 020 R» «LAG 024 R» USER’S MANUAL IMPORTANT This appliance must be installed in accordance with all relevant standards and regulations in force in a room with adequate ventilation. Any change of voltage from that for which the appliance is set up must be carried out by a qualified installer.
  • Page 9: Gas Hob

    GAS HOB CLEANING AND MAINTENANCE Use: Before any cleaning work, close the gas supply and/or isolate from the mains electricities supply Simultaneously press in and turn the burner dial anti-clockwise to setting « ». Press the ignition button while maintaining pressure on burner dial for about 20 seconds to ignite WARNING Do not use a steam cleaner to clean the range.