HYDRONIC RADIANT HEATING SYSTEM
Hydronic radiant heating & cooling systems can be installed in many ways to create a wonderfully
warm room environment.
These include:
1. Pipes embedded in the concrete floor.
2. Pipes in a floating floor system.
3. Pipes fixed to the underside of a wooden floor.
4. Pipes embedded in the walls of a room.
5. Pipes embedded in the ceiling of a room.
6. All these methods offer many practical benefits to suit the needs of all.
7. Hydronic radiant heating has been used for centuries. In the last few years, significant improvements in
the technology together with the realisation of the benefits of this form of heating and cooling have created
a rapid rise in installations.
Benefits
-
Tiemme
radiant floor, wall or ceiling
heating, provides energy saving with comfort, quiet
and clean operation, with room versatility and choice
of energy usage.
Energy Saving
- Room temperatures can be set as
much as 3 degrees lower and still maintain the
required comfort level. In houses with high ceilings the
savings can be significant.
Ultimate Comfort
- Rooms can be heated to different
temperatures according to their usage. Zones can be
set to heat rooms at different times to eliminate cold
rooms often during a relative short period of usage.
The floors are always comfortably warm no matter
what the floor coverings are.
Quiet Operation
-
Tiemme
systems operate without noise and draughts. Air movement is kept to a minimum so dust and germs are not spread
around the house.
Choice of Surfaces
-
Tiemme
suspended below with wooden floors and even in the walls or ceiling. The choices are unlimited.
Freedom to decorate
- As the heat gently radiates from the whole of the floor there are no obstructions or
limitations for the placement of furniture.
Choice of energy
Tiemme
and solar collectors, solid fuel boiler or any new energy system yet to be discovered. This means your heating
system is always ready for the future.
Healthy Choice
- Over the years people who have switched from forced air to floor radiant heating have greatly
improved their allergy problems. This is attributed to less dust blowing around.
Zero maintenance
- Once installed
cleaning.
1
page -
-
Australian Hydronic Supplies
10 Frankston Gardens Drive
Carrum Downs, Victoria,
Australia 3201
Tiemme
has been one of the companies leading the way.
radiant floor heating
radiant heating systems can be installed in a concrete floor on the ground or
radiant systems can be powered by a gas-fired boiler, a combination of heat pump
Tiemme
radiant floor heating does not require routine maintenance or

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TIEMME and is the answer not in the manual?

Questions and answers

Summary of Contents for Australian Hydronic TIEMME

  • Page 1 Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 HYDRONIC RADIANT HEATING SYSTEM Hydronic radiant heating & cooling systems can be installed in many ways to create a wonderfully warm room environment. These include: 1. Pipes embedded in the concrete floor.
  • Page 2: Table Of Contents

    Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 The following manual will show you How radiant under floor heating is - selected - installed - operated A l l f o r y o u r b e n e f i t P l e a s e r e a d t h i s m a n u a l c a r e f u l l y INTRODUCTION.
  • Page 3: Introduction

    (50) years ago, since then many millions of metres of Tiemme pipe have been installed and continue to give trouble free service. Tiemme pipe is manufactured and certified in accordance to EN-ISO 15875 & IPP n⁰16 standards 1.1 Technical details Material : PE-Xb CobraPex...
  • Page 4: Radiant Under Floor Heating

    Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 2.0 Radiant under floor heating 2.1 How does it work? ”What exactly is radiant energy?” Hold your hand over a hot cup of coffee and feel the heat. The logical conclusion is that heat rises.
  • Page 5 Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 How is it selected? 2.2.1 Getting started A qualified heating engineer or a qualified mechanical services installer should select your radiant underfloor heating system. 2.2.3 The heated floor The slab will naturally dissipate heat through the media in an upward direction and provide uniform heat transference.
  • Page 6: Heat Loss Calculations

    Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 3.0 Heat loss calculations All heat loss calculations should be made by a suitably qualified person, so that the building is not over or under capitalised on the heating equipment. Over capitalised means too much money has been spent, but the system will perform very well.
  • Page 7 Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 3.1.2 Slab construction Examples of slab constructions are detailed below: Heated Room Heated Room Distance from top of pipe to surface of concrete - Maximum 65 mm Minimum 30 mm Compacted Fill FIG.
  • Page 8 Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 FIG. 2 pipe in slab with insulation Heated Room Tiles Mortar Bed Screed Tiemme pipe Polyethylene membrane Insulation Moisture Barrier Concrete slab Consolidated earth FIG. 3 Pipe in Screed installation...
  • Page 9 Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 3.2 Heat output Tiemme 16mm x 2.0mm pipe Calculate the heat output at various room and water flow temperatures of Floor Room temp Room temp Room temp Room temp...
  • Page 10 Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 Calculate the heat output at various room and water flow temperature of Floor Room temp Room temp Room temp Room temp Room temp Pipe spacing covering – Floor –...
  • Page 11: Planning - Laying Out The System

    Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 4.0 Planning - laying out the system Every system has to be precisely planned to maximise the comfort and energy efficiency of the system. The flexibility of the underfloor heating allows heating to be concentrated where needed most and reduced where little or no heat is required.
  • Page 12: Useful Information

    Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 5.0 Useful information 5.1 Water flow rates Water flow rates can be calculated from the following formula: Water Flow (l/s) = KW / x 4.187 x temp change K - (K usually 10 –...
  • Page 13: Selecting A Heat Source

    Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 6.0 Selecting a heat source The choice of heat source for Tiemme floor heating is almost unlimited requiring only a flow and temperature controlled water flow. The possibilities include; geothermal, gas-fired boilers, electric boilers, wood-fired boilers and heat pumps.
  • Page 14 Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 6.2 Electric boilers These can be categorised as the following: Off peak Laing electric boilers. An option when efficiency of the Tiemme floor heating system giving a natural gas is not available. Usually requires three...
  • Page 15: Information For The Builder

    Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 7.0 Information for the builder Full co-operation and communication between the builder and you the under floor heating installer is required to co-ordinate the installation of the heating system during the construction phase of the building.
  • Page 16: How It Is Installed

    Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 Manifold Tiemme 8.0 How it is installed? 8.1 Before you start installing the pipe 1. All formwork has to be finished and mesh installed on all parts of...
  • Page 17 Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 8.2 Laying the pipe 1. Use a de-coiler to unwind the pipe off the coil without kinking the pipe. 2. Use conduit type cutter to produce a clean burr free cut 3.
  • Page 18 Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 8.4 Pipe in screed installation method Install Polystyrene insulation over the concrete heated screed and prevents thermal and slab acoustic bridging to the outside wall. Place polyethylene membrane...
  • Page 19 Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 8.5 Pouring the slab Ensure that the screed used in the concrete If the pipe is damaged during the pour, is suitable for underfloor heating. immediately remove the wet concrete...
  • Page 20: Manifold System

    Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 9.0 Manifold system System 2000 MULTIMODUL Definite A d v a n t a g e s • • Valves for every loop are already part Easy connection to...
  • Page 21 Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 9.1 Manifold dimensions Drawn as a 6 port header No. Circuits L - no ball valves L - with ball Valves B - Bracket centres 9.2 Assembly of the manifold Please read these instructions carefully before commencing the assembly of the manifold.
  • Page 22 Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 9.3 Manifold water pressure drops MANIFOLD FLOW RATE SETTINGS AND PRESSURE LOSS Flow T o t a l M a n i f o l d F l o w 5 .
  • Page 23 Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 D i s t r i b u t o r B o x V K 6 0 0 0 • F l u s h m o u n t e d b o x w i t h c o u n t e r s u n k l o c k .
  • Page 24: Expansion Vessels Sizing

    In operation this usually shows with boiler pressure of 3 Bar and water flowing through the pressure relief valve. Australian Hydronic Supplies Pty Ltd is able to provide support and guidance in designing and installing underfloor heating systems. On site, technical support is available at all times from experienced sales engineers.
  • Page 25: Floor Coverings

    Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 11.0 Floor coverings The following points in particular should be noted: 1. Use water based adhesive under all floor tiles. 2. Any expansion joints should continue through to the hard floor coverings eg ceramic tiles or wood.
  • Page 26: How Is It Operated

    Australian Hydronic Supplies 10 Frankston Gardens Drive Carrum Downs, Victoria, Australia 3201 12.0 How is it operated? 12.1 Control systems It is important to have an effective control system to minimise running costs. An automatic time clock thermostat with night setback should be fitted as a minimum. From this point, a number of options are available to enhance the system.