Daikin EBHQ011BA6V3 Manual page 6

Monobloc
Hide thumbs Also See for EBHQ011BA6V3:
Table of Contents

Advertisement

2
Specifications
2-4 ELECTRICAL SPECIFICATIONS
Power supply
Voltage range
hydraulic
component
Wiring connections
Notes
86
• Monobloc • EBHQ011-016BA6V3
Minimum
V
Maximum
V
Connection type
Quantity of wires
Type of wires
Connection type
Quantity of wires
Type of wires
Type of wires
Connection type
Quantity of wires
Type of wires
Connection type
Quantity of wires
Type of wires
Type of wires
Connection type
Quantity of wires
Type of wires
Type of wires
Connection type
Quantity of wires
Type of wires
Type of wires
In accordance with EN/IEC 61000-3-11 (1), it may be necessary to consult the distribution network
operator to ensure that the equipment is connected only to a supply with Zsys (3) smaller than or equal
Installer can reduce capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A.
Installer can reduce capacity of the heater from 6 to 3.5kW. The current is then reduced from 8.7 to
(1)European/International Technical Standard setting the limits for voltage changes , voltage
fluctuations and flicker in public low-voltage supply systems for equipment with rated current <= 75A.
(2) European/International Technical Standard setting the limits for harmonic currents produced by
equipment connected to public low-voltage systems with input current > 16A =< 75A per phase.
Power supply hydraulic compartment is for the electric heater. The optional domestic warm water tank
• Daikin Altherma • Monobloc
EBHQ011BA6V3
EBHQ014BA6V3
for power supply hydraulic compartment
Select diameter and type according to national and local regulations
for power supply connection to optional sanitary tank + Q2L
Select diameter and type according to national and local regulations
For more details on voltage range and current refer to installation manual
for connection with R5T
Wire included in option EKHWS*
Wire included in option EKHWS*
for connection with A3P
Depends on thermostat type, refer to installation manual
Select diameter and type according to national and local regulations
Voltage 230V / Maximum current: 100mA / Minimum 0.75mm²
for connection with M2S
Select diameter and type according to national and local regulations
Voltage 230V / Maximum current: 100mA / Minimum 0.75mm²
for connection with M3S
3G or 4G
Select diameter and type according to national and local regulations
Voltage 230V / Maximum current: 100mA / Minimum 0.75mm²
Power supply compressor compartment is for compressor, fan, pump and controller
to Zmax.
Instructions see installation manual.
5A. Instructions see installation manual.
(3) System impedance
has a separate power supply.
Conditions: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
EBHQ016BA6V3
-10%
+10%
3G
3G
3G