2.2 Programming

HTTP Settings

Parameter & Description
#
HTTP Port No.
Specifies the port number for HTTP communications by the
card.
Generally, there is no need to change the default value.

QSIG Connectionless Tunneling Settings

Parameter & Description
#
QSIG Connectionless Tunneling Port No.
Specifies the port number for connectionless tunneling
between cards at different locations in a QSIG network.
Generally, there is no need to change the default value.
Notes
Connectionless tunneling enables the PBXs on a
QSIG network to use enhanced networking
features. (For more information about these
features, refer to the relevant sections of the Hybrid
IP-PBX documentation.)
If you are using a gatekeeper, and enhanced
networking features of the PBX are being used,
overall performance of the card may deteriorate
when network traffic is heavy.
If you are using a gatekeeper, and "Routed" is
specified for the parameter Call Signaling Model
(see "2.2.2 H.323 Parameters"), connectionless
tunneling is not possible. In this case, the PBX
cannot use the enhanced networking features.
Others
Parameter & Description
Host Name
This parameter is provided for engineer use only.
#
LAN Disconnect Threshold Time (s)
Specifies the time (in seconds) until disconnection from the
LAN is recognized.
For example, even if a LAN cable is disconnected during a
call, reconnecting the cable within this time period maintains
the call.
12
Programming Guide
Default
Value Range
80
1 to 65535
Default
Value Range
1718
1 to 65535
Default
Value Range
VoIP + lower 3
Max. 255 characters
bytes of the MAC
address
5
1 to 10