Cause
Chainsaw does not operate
Chainsaw operates irregularly
Saw chain dry
Chain/guide rail hot
Chainsaw jumps up, vibrates or
does not saw properly
We, ikra GmbH, Schlesierstraße 36, 64839 Münster GERMANY, declare under our sole responsibility that the
product Electric branch saw EAS 750F, to which this declaration relates correspond to the relevant basic safety
and health requirements of Directives 2006/42/EC (Machinery Directive), 2014/30/EU (EMC-Guideline), 2011/65/
EU (RoHS-Guideline) and 2000/14/EC (noise directive) incl. modifications. For the relevant implementation of the
safety and health requirements mentioned in the Directives, the following standards and/or technical specification(s)
have been respected:
EN 60745-1:2009/A11:2010, EN ISO 11680-1:2011, AfPS GS 2014:01 PAK
EN 55014-1/A2:2011; EN 55014-2/A2:2008; EN 61000-3-2:2014; EN 61000-3-3:2013
Type examination certificate No. M6A 16 05 32082 134; TÜV SÜD Product GmbH, Identity no. 0123
measured acoustic capacity level
guaranteed acoustic capacity level
Conformity assessment method to annexe V / Directive 2000/14/EC
The year of manufacture is printed on the nameplate and can be additionally retrieved via the consecutive serial number.
Münster, 27.09.2016
Maintenance of technical documentation: Gerhard Knorr, Kärcherstraße 57, DE-64839 Münster
GB | Operating Instructions
Fault
No current supply
Defective outlet
Extension cable damaged
Defective fuse
Mains cable damaged
External loose connection
Internal loose connection
Defective on/off switch
No oil in the tank
Ventilation in the oil tank cap clogged
Oil tank flow channel clogged
No oil in the tank
Ventilation in the oil tank cap clogged
Oil tank flow channel clogged
Dull chain
Chain tension too loose
Dull chain
Chain worn out
Saw teeth pulling in the wrong
direction

15. EC Declaration of Conformity

105,1 dB (A)
108,0 dB (A)
Gerhard Knorr, Technical Management Ikra GmbH
11
Remedy
Check current supply.
Try a different source of current,
change as necessary.
Check cable, replace if necessary.
Replace fuse
Take saw to a specialty workshop
Take saw to a specialty workshop
Take saw to a specialty workshop
Take saw to a specialty workshop
Re-fill oil
Clean oil tank cap
Unclog oil flow channel
Re-fill oil
Clean oil tank cap
Unclog oil flow channel
Re-sharpen or replace chain
Adjust chain tension
Re-sharpen or replace chain
Replace chain
Re-mount saw chain with
teeth in the correct direction

Hide quick links: