Ceiec Electric PMC-1220E User Manual

Industrial rs485 hub

Advertisement

Quick Links

PMC-1220E
Industrial RS485 Hub
User Manual
Version: V1.0A
01/10/2013
Ceiec Electric Technology

Advertisement

Table of Contents
loading

Summary of Contents for Ceiec Electric PMC-1220E

  • Page 1 PMC-1220E Industrial RS485 Hub User Manual Version: V1.0A 01/10/2013 Ceiec Electric Technology...
  • Page 2 Ceiec Electric Technology This manual may not be reproduced in whole or in part by any means without the express written permission from Ceiec Electric Technology (CET). The information contained in this manual is believed to be accurate at the time of publication;...
  • Page 3: Limited Warranty

    Ceiec Electric Technology Limited warranty  Ceiec Electric Technology (CET) offers the customer a minimum of 12-month functional warranty on the device for faulty parts or workmanship from the date of dispatch from the distributor. This warranty is on a return to factory for repair basis.
  • Page 4: Table Of Contents

    Ceiec Electric Technology Table of Contents Chapter 1 Introduction ........................5 1.1 Overview ............................ 5 1.2 Features ............................5 1.3 Typical Applications ........................ 5 1.4 Getting more information ..................... 5 Chapter 2 Installation ........................6 2.1 Appearance ..........................6 2.2 Unit Dimensions ........................
  • Page 5: Chapter 1 Introduction

    The PMC-1220E is an Industrial RS485 hub with one upstream port and four downstream ports. Not only can the PMC-1220E be used to increase the number of RS458 nodes beyond the 32 limit, it can also be used to simplify the wiring for a RS-485 network by splitting a long segment into four individual shorter segments, thus reducing labor and material costs while expanding the coverage area.
  • Page 6: Chapter 2 Installation

    Chapter 2 Installation 2.1 Appearance Figure 2-1 Appearance 2.2 Unit Dimensions Figure 2-2 Dimensions 2.3 Mounting The PMC-1220E should be installed in a dry environment with no dust and kept away from heat, radiation and electrical noise source. Installation steps: Wall Mounting...
  • Page 7 Before installation, make sure that the 35mm DIN-Rail is already in place  Align the top of the mounting clip at the back of the PMC-1220E at an angle against the top of the DIN rail as shown in the figure below ...
  • Page 8: Power Supply Wiring

    Figure 2-3-2 DIN-Rail Mounting 2.4 Power Supply Wiring The PMC-1220E comes standard with a 95-250VAC/DC universal power supply. For AC supply, connect the live wire to the L/+ terminal and the neutral wire to the N/- terminal. For DC supply, connect the positive wire to the L/+ terminal and the negative wire to the N/- terminal.
  • Page 9: Chapter 3 Application

    3.1 LED Indicators PMC-1220E’s front panel is equipped with six LED indicators – P0, P1, P2, P3, P4 and PWR. When power is applied, the PWR indicator will lit up. When the serial ports (P0, P1, P2, P3 and P4) are connected and have activities, the Px (P0, P1, P2, P3, P4) indicator will blink.
  • Page 10: Chapter 4 Communication Settings

    The communication settings for the PMC-1220E are controlled by Jumpers on its PCB. To configure the PMC-1220E, the metal enclosure must first be removed to reveal the Jumpers' locations. Jumpers J1 to J8 are located on the PMC-1220E’s PCB as illustrated in Figure 4-1 below. Figure 4-1 Jumper Locations...
  • Page 11: Communication Format Settings (J3)

    In certain situation, a termination resistor may be required to prevent signal reflection that would cause serial data corruption. The PMC-1220E comes equipped with a built-in 120 Ω termination resistor for each RS485 port that can be enabled by changing the jumper settings on the PCB board.
  • Page 12: Appendix A Technical Specifications

    Ceiec Electric Technology Appendix A Technical Specifications Serial Ports (P0, P1, P2, P3, P4) Standard RS485 Port Baud rate 1200 to 38,400bps LED Indicators Power (Red) Supply power indicator P0 (Green) Upstream RS485 activities on Port 0 P1 (Green) Downstream RS485 activities on Port 1...
  • Page 13: Appendix B Standards Of Compliance

    Ceiec Electric Technology Appendix B Standards of Compliance Safety Requirements Insulation IEC 60255-5-2000 Dielectric Test 2kV @ 1 minute Insulation Resistance >100MΩ Impulse Voltage Electromagnetic Compatibility Electrostatic Discharge IEC 61000-4-2:2008 Level III Radiated Fields IEC 61000-4-3:2008 Level III Fast Transients...
  • Page 14: Appendix C Ordering Guide

    Ceiec Electric Technology Appendix C Ordering Guide Contact us Ceiec Electric Technology Inc. Headquarters 8/F, Westside, Building 201, Terra Industrial & Tradepark, Che Gong Miao, Shenzhen, Guangdong, P. R. China 518040 Tel: +86.755.8341.5187 Fax: +86.755.8341.0291 Email: support.international@ceiec-electric.com Web: www.ceiec-electric.com...