Setup State 3 Guard Tone Level

The Guard Tone Level setup state is used to set the level of the guard tone. The guard tone has a 40dB range. The values in
between those shown in Table 5 are valid as well. For example 25 would result in an output level of -6dB for the guard tone.
To set the guard tone level, do the following:
Select the setup option using FUP/FDWN keys.
1.
Press Enter (#).
2.
Display shows OC (Option Changed).
Guard Tone Level
TABLE 5.
Option
Level
1
-30dB
11
-20dB
21
-10dB
25
-6dB
31
0 dB
41 (default)
+10dB

Setup State 4 Guard Tone Duration

The Guard Tone Duration setup state can vary from 0 to 500ms and is configurable to the nearest 10ms. The setup option is
offset by one (1) and multiplied by 10. Any value between those in Table 6 is valid.
To set the tone duration, do the following:
Select the setup option using FUP/FDWN keys.
1.
Press Enter (#).
2.
Display shows OC (Option Changed).
Guard Tone Duration
TABLE 6.
Option
Duration
1
0 ms
14 (default)
130ms
51
500ms

Setup State 5 Hold Tone Level

The Hold Tone Level setup state is used to set the level of the hold tone. The Hold tone has a 40dB range. The values in
between those shown in Table 7 are valid as well, for example 25 would result in an output level of -6dB for the hold tone.
To set the hold tone level, do the following:
Select the setup option using FUP/FDWN keys.
1.
Press Enter (#).
2.
Display shows OC (Option Changed).
Hold Tone Level
TABLE 7.
Option
Level
1
-30dB
11 (default)
-20dB
21
-10dB
25
-6dB
31
0 dB
41
+10dB