1. Move the cursor to the FLM/FRM parameter.
2. Select FLM (field) or FRM (frame).
Note:
When FRM is selected, ELC is set to OFF automat-
ically.
3. Electronic Light Control Setting (ELC)
The electronic light control function eliminates interfer-
ence by strong background lighting which makes the
camera picture dark, such as a spotlight. In the ELC
mode, more photometric weight is given to the desired
point of the screen (to where the important object is
located).
CAMERA ID
FLD/FRM
ELC
SHUTTER
GAIN
SYNC
BLACK BAL
SCENE FILE
END
3-1. ELC detection control area setting (ELC CONT)
1. Select ON for the ELC ON/OFF selector on the front
panel of the camera control unit. Then confirm the ELC
parameter is ON.
2. Move the cursor to the ELC parameter and press the
PAGE button.
The ELC CONT menu appears.
** ELC CONT **
AREA
PEAK/AVE
RET
14
** SET UP **
*OFF
FLD
*ON
OFF
AUTO
INT
ABC
*SCENE1
ON
OFF
ELC
ALL
P....I....A
END
3. Move the cursor to the AREA parameter and select the
desired detection area. You can select the desired
detection area from followings.
ALL: All areas on the monitor screen are detected.
MANU: Detection areas are selectable manually. See
below for details.
CENTER: The photometric weight is given to the cen-
ter of the monitor screen.
S CIRCLE (Small Circle): The photometric weight is
given to the area within a small circle in the center
of the monitor screen.
M CIRCLE (Medium Circle): The photometric weight is
given to the area within a medium large circle in the
center of the monitor screen.
L CIRCLE (Large Circle): The photometric weight is
given to the area within a large circle in the center
of the monitor screen.
Each time you press A or B, the parameter changes
as follows.
ALL
MANU
CENTER
M CIRCLE (Medium Circle)
ALL
CENTER
S CIRCLE
(Small Circle)
S CIRCLE (Small Circle)
L CIRCLE (Large Circle)
Detection Area
Detection Area
50% Sensing
Area
100% Sensing
Area
Detection Area