Reading Out Measured Values - Vivadens MCR 24/28 BIC PL User Manual

Wall-hung gas condensing boilers
Table of Contents

Advertisement

5. Operation
5.6

Reading out measured values

21
The following values can be displayed in the information menu Q:
4 t1 = Flow temperature (°C)
4 t2 = Return temperature (°C)
4 t3 = DHW sensor temperature (°C)
This temperature is used only for internal management in DHW
mode. During DHW draw-off, this value does not correspond to
the actual DHW outlet temperature (it is always lower).
4 t4 = Outside temperature (°C)
4 fl = Ionization current (μA)
4 Mf = Fan speed (rpm)
1. Press the f key. The symbol Q flashes.
2. To access the parameters, press key S .
3. Press the [+] key successively to scroll down the various
parameters.
4. Press the > key 2 times to return to the current operating mode
T000138-A
MCR 24/28 BIC PLUS
170915 - 300024112-001-06