Setting The Inside Temperature; Maintenance - Kenworth SP671-PT1132 Owner's Manual

Indel b pn sp671-sp658
Table of Contents

Advertisement

KENWORTH SP671-PT1132 (Indel B PN SP671 - SP658)

1.4 SETTING THE INSIDE TEMPERATURE

The refrigerators are provided with a manual thermostat. Turn it clockwise to lower the temperature, and
turn it counterclockwise to raise the temperature and activate the ON-OFF switch in its end position. The
knob of the thermostat is located inside the refrigerator, on the right side.
1.4.1 DEFROSTING
Defrosting must be carried out when the ice layer is thicker than 4 mm.
Set the thermostat at the OFF position. While defrosting, keep food and beverages in a cool place. Do
not use any sharp metal object to remove the ice or frost. Do not start the refrigerator up again until it is
completely defrosted and dry. Also empty the main tray.

1.5 MAINTENANCE

Warning
Before every maintenance operation, disconnect the power supply from the electric outlet. In case of
refrigerator wrong operation, contact the Indel B Service Center.
1.5.1 CLEANING
Periodically clean the inside of the refrigerator using sodium carbonate dissolved in lukewarm water. Avoid
using abrasive products, cleaners or soaps. After cleaning, rinse with fresh water and dry with care. When
you are not using the refrigerator, clean and dry its inside to prevent mould and bad smells formation.
Warning
Do NOT wash the refrigerator drawers and parts in a Dishwasher.
1.6 USEFUL ADVICES
If the refrigerator does not work, or if it works wrongly, before referring to our after sales service (Customer
Care Dept- Indel B North America - ph 502-863-0397), make sure that:
a) power is not missing.
b) the voltage which reaches the station is equal to the one shown on the plate.
c) the connections are correctly made.
d) the ventilation grids are not obstructed.
e) the refrigerating unit is not near a source of heat.
f) the fuse mounted on the feeding line is not blown.
1st - If nothing is running or only fan is running, using a volt meter on 20v DC setting, check voltage at
fridge with truck off and fridge off . What is voltage?  Turn fridge on and see if voltage drops below 11
volts.  If yes, there is most likely a wiring issue with the truck.  If no, proceed to next step (for details
go to Chapter 2 "How to detect functional problems and fix them")
2nd - If fan does not run, bypass thermostat wires on ECU terminal C to T.  If fan now runs, also check if
compressor is now running and if yes replace thermostat.
3rd -  If fan runs and compressor does not, change ECU and check if compressor is now running.
Warning
the power cable must be replaced only by qualified technical personnel and, in any case, by a service
authorized by the manufacturer.
INDEL B disclaims any responsibility if the above instructions and conditions are disattended or not met.