Moore FCT [UB] Manual

Signal converter/isolator

Advertisement

Page 1
FCT
FCT [UB]
April 2016
Signal Converter/Isolator
146-715-00 B
[UB]
SIGNAL CONVERTER/
FCT
ISOLATOR
SPAN
ZERO
The Interface Solution Experts

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FCT [UB] and is the answer not in the manual?

Questions and answers

Summary of Contents for Moore FCT [UB]

  • Page 1 Page 1 FCT [UB] April 2016 Signal Converter/Isolator 146-715-00 B [UB] SIGNAL CONVERTER/ ISOLATOR SPAN ZERO The Interface Solution Experts...
  • Page 2: Table Of Contents

    Page 2 FCT [UB] Table of Contents Introduction Description Specifications Ordering Information Calibration Installation Operation Customer Support The Interface Solution Experts...
  • Page 3: Introduction

    Page 3 FCT [UB] Introduction Description Moore Industries’ FCT [UB] Signal Converter/ The FCT [UB] is a compact, versatile device, Isolator takes in either current or voltage input and featuring universal powering, and user-set zero and provides isolated current or voltage output.
  • Page 4: Specifications

    Page 4 FCT [UB] Specifications Accuracy: ± 0.1% of Performance Performance Maximum Input Transmitter Excitation Performance span (includes (continued) Overrange: Voltage (continued) (Optional): Regulated, adjustment resolution inputs, ±60V; Current 24Vdc @ 25mA for one, and linearity) Inputs, ±50mA for 2-wire external transmitter Isolation: 1000Vrms 0-20mA inputs, ±100mA between input, output...
  • Page 5: Calibration

    Every product Moore Industries manufactures, sells calibrating the FCT [UB]. These items are not and services is guaranteed to meet the strict quality supplied by Moore Industries, but should be standards that have become synonymous with our available in most testing labs.
  • Page 6 Page 6 FCT [UB] Figure 1. Calibrating the FCT [UB] SPAN ZERO ADJUSTABLE SIGNAL SOURCE –IN – (VOLTAGE OR – VDC OR VAC CURRENT) POWER +OUT SOURCE VOLTAGE –OUT CURRENT – METER To Calibrate Zero and Span: Calibrating Zero and Span Before beginning this procedure, check the model 1.
  • Page 7: Installation

    Installation of the FCT [UB] is a two-step process. First, the unit is mounted, and then the electrical connections are made. Before installing the FCT [UB], Moore Industries suggests that the calibration procedures be carried out to confirm that the configuration of the unit is appropriate for the intended application.
  • Page 8: Operation

    • Any Moore Industries product in a metal case your answers more efficiently. When you call, or housing should be grounded.
  • Page 9 Page 9 FCT [UB] Figure 3. Installing the FCT [UB] SPAN ZERO VOLTAGE VOLTAGE –IN – – VDC OR VAC TRANSMITTER POWER +OUT SOURCE RECEIVER –OUT – Figure 3. Installing the FCT [UB] with the -TX option SPAN ZERO 2-WIRE TRANSMITTER (4-20mA) –...
  • Page 10 4. Ship the equipment to the Moore Industries location nearest you. The returned equipment will be inspected and tested at the factory. A Moore Industries representative will contact the person designated on your documentation if more information is needed. The repaired equipment, or its replacement, will be returned to you in accordance with the shipping instructions furnished in your documentation.