Advertisement

Quick Links

User's Guide
Digital Mini Multimeters

Advertisement

Table of Contents
loading

Summary of Contents for Veto DT-18

  • Page 1 User's Guide Digital Mini Multimeters...
  • Page 2: Table Of Contents

    User's Guide of Digital Mini Multimeters DT-16/DT-18 ConTenTs 1 Summary..................04 2 Guidelines of safety operation............04 3 Integrated indicators..............06 4 Safety signs................07 5 Meter Layout................07 5.1 DT-18..................07 5.2 DT-16..................08 6 Key functions and auto power off..........09 6.1 SELECT Button..............09 6.2 RELATIVE Button..............09 6.3 DATA HOLD Button..............09...
  • Page 3 User's Guide of Digital Mini Multimeters DT-16/DT-18 7.5 Diode and Buzzer on-off measurement........14 7.6 Capacitance measurement (Figure 4 the dashed box shown is limited to DT18).............15 8 Technical Specifications..............15 9 Battery replacement..............19 - 03 -...
  • Page 4: Summary

    1 sUMMary DT-16/DT-18 is a portable notebook autoranging digital multimeter (DT-16 is 3 1/2 and DT-18 is 3 3/4). It is a full - featured, stable performance, high precision, low power consumption and novel structure, safe and reliable multimeter, and it can be used to measure AC/DC voltage, frequency, duty cycle, resistance, ca pacitance, diode forward voltage drop and on-off test.
  • Page 5 User's Guide of Digital Mini Multimeters DT-16/DT-18 display. 2. When using the probe, your finger must be placed after the probe finger gDTrd ring. 3. Do not apply voltage more than 500V between the meter terminal and ground to prevent electrical shock and damage to the meter.
  • Page 6: Integrated Indicators

    User's Guide of Digital Mini Multimeters DT-16/DT-18 3 inTeGraTeD inDiCaTors 1. The maximum voltage of the voltage input terminal and the ground: 500Vrms or 500DCV 2. Range: Automatic 3. Measurement rate: 3 times/second 4. The maximum display: 3999, 3 3/4 ( DT16 is 1999, 3 1/2) 5.
  • Page 7: Safety Signs

    User's Guide of Digital Mini Multimeters DT-16/DT-18 4 safeTy siGns Power insufficient Ground Warning Capacitance Double insulation Buzzer pass-off Diode AC or DC License of China Technical Supervision measuring equipment manufacturing Accordance with European Union standard 5 MeTer layoUT 5.1 DT-18 1.
  • Page 8: Dt-16

    User's Guide of Digital Mini Multimeters DT-16/DT-18 3. Relative value measurement (RELATIVE) 4. Data keeping switch HOLD (DATA HOLD) 5. Hz/DUTV measurement ( DCV and ACV FILE) 6. Function switch 7. Measurement positive input terminal (red probe) 8. Measurement positive input terminal (black probe) 5.2 DT-16...
  • Page 9: Key Functions And Auto Power Off

    (For DT16, is no capacitor switching). In sleeping mode, press this key to wake the meter and the automatically power-off function will be cancelled. (Only for DT-18). 6.2 relaTiVe Button When press this button, the meter will display the current value as a reference value, after that, the readings of measurement will automatically subtracting this reference value.
  • Page 10: Range Button

    For DT-18, during the measurement, the instrument will be in “Automatic Shutdown” (hibernation) to conserve power, if the function keys and dial switch have no action within 30 minutes. And...
  • Page 11: Operating Instructions

    User's Guide of Digital Mini Multimeters DT-16/DT-18 power off function will be cancelled. Under auto power off state, press function keys or turn the dial switch, and the instrument will switch on automatically. 7 operaTinG insTrUCTions When the instrument power is turned on, please observe the LCD screen, such as a “...
  • Page 12: Acv Measurement

    User's Guide of Digital Mini Multimeters DT-16/DT-18 ⑵ Put rotary switch to DCV files. ⑶ Please read the measured voltage value directly from the display. ⑷ The LCD will display negative readings if exchange the probes. Cautions: Don’t input the voltage above 500V. It is possible to measure higher voltage but it will damage the instrument.
  • Page 13: Hz And Duty Measurement (Figure 4 The Dashed Box Shown Is Limited To Dt18)

    At last, the short-circuit value should be subtracted from the final value. For DT-18, the RELATIVE measurement function is suggested to use. The display will show “OL” if there is no input, for example, the tested resistance of the circuit is open.
  • Page 14: Diode And Buzzer On-Off Measurement

    User's Guide of Digital Mini Multimeters DT-16/DT-18 ⑸ Press the Hz and Duty button again and start the DUTY measurement. Cautions: The tested resolution has a little difference according to the input frequency and waveform. The resolution of the instrument is according to the sine wave to develop.
  • Page 15: Capacitance Measurement (Figure 4 The Dashed Box Shown Is Limited To Dt18)

    User's Guide of Digital Mini Multimeters DT-16/DT-18 ACV>30V. 7.6 Capacitance measurement (figure 4 the dashed box shown is limited to DT18) ⑴ Put rotary switch to Ω file. ⑵ Press SELECT button three times and the instrument starts capacitance measurement.
  • Page 16 User's Guide of Digital Mini Multimeters DT-16/DT-18 Environmental temperature: 18°C~28°C Environmental humidity: ≤75%RH DT-18 DCV: automatic range Input Function Range Resolution Accuracy Notes protection 400mV 0.1mV ±(0.8%+3) 1 mV 500V DC Input Impedance 10 Mv ±(0.8%+1) 500V AC ≥100MΩ 400V...
  • Page 17 User's Guide of Digital Mini Multimeters DT-16/DT-18 400Ω 0.1Ω ±(1.2%+5) 4kΩ 1Ω 40kΩ 10 Ω ±(1%+2) Voltage of open Ω 250V AC circuit it 0.45V 400kΩ 100 Ω 4MΩ 1kΩ ±(1.2%+2) 40MΩ 10 kΩ ±(1.5%+2) DT-16 aCV and resistance: automatic range...
  • Page 18 User's Guide of Digital Mini Multimeters DT-16/DT-18 4.000μF 0.001μF Voltage of open circuit it 0.45V ±(4%+3) 40.00μF 0.01μF Display: sine CAP(F) 250V AC wave valid value Take long time if 100μF 0.1μF ±(5%+10) input>10μF 99.99Hz 0.01 Hz Input voltage is sine wave 999.9Hz...
  • Page 19: Battery Replacement

    User's Guide of Digital Mini Multimeters DT-16/DT-18 9 BaTTery replaCeMenT When the LCD display under voltage " " prompt, it should be to replace the built-in battery otherwise it will affect the measurement accuracy. Steps: 1. The power switches to "off" position, and make the probe away from the input jack.