  • Page 1 80K Owner’s Manual • Specifications • Installation • Maintenance Caution: Read manual carefully for proper procedures and operation.
  • Page 2: Table Of Contents

    CONGRATULATIONS on your purchase of an Duct Pure 80K air purification enhancement system . This unit is designed to be installed into an existing HVAC system, and used as a virtually maintenance free enhancement to current air purification technology .
  • Page 3: Product Contents

    INSTALLATION HARDWARE (8) Self-tapping Screws (4) Brass Thumb Nuts REPLACEMENT PARTS The PCO Cell is the only replacement part available for the Duct Pure 80K . Please contact your distributor for your new cell replacements . PCO Cell Part Number: CELL-HV-14-O3-GT...
  • Page 4: About Duct Pure 80K

    ABOUT Duct Pure 80K Duct Pure 80K is a new generation HVAC Air purification system . Designed to work with existing purification technology to reduce odors, smoke, and a broad spectrum of indoor air contaminants . Duct Pure 80K is easily mounted into air conditioning and heating system air ducts where many problem can start .
  • Page 5: Recommended Installation Tools

    RECOMMENDED INSTALLATION TOOLS A - 3 .5” Hole Saw Bit D - Utility Knife B - 3/8” Drill Bit E - Tin Snips C - Drill/Power Driver F - Phillips Head Screwdriver INSTALLATION REQUIREMENT Unit should be installed downstream of the air handler in the HVAC system .
  • Page 6: Installation

    INSTALLATION Find a suitable location to mount your Induct Unit . If necessary, cut away insulation for your plate to adhere to the duct . Using the Adhesive Gasket Plate, trace the hole locations onto the duct . Use the Hole Saw and Drill to cut out the marked holes .
  • Page 7 ALTERNATIVE CUTTING METHOD Using the Adhesive Gasket Plate, trace the hole locations onto the duct . Drill holes around the outside edges of the prviously marked holes but inside the outer holes of the Adhesive Gasket Plate . Use the Tin Snips to cut out the space around the marked holes .
  • Page 8: Installation

    INSTALLATION Remove the plastic backing on your Adhesive Gasket Plate . Press the Adhesive Gasket Plate onto the duct . Secure with the (8) Self-Tapping Screws . Place the Unit and Cells through the openings and secure with the (4) Brass Thumb Nuts .
  • Page 9: Maintenance/Uv Lamp Indicator

    Please do not throw a used PCO Cell in the garbage . The special germicidal UVX bulb used in the Duct Pure 80K contains a very small amount of mercury . Contact your local Waste Management Center for a proper disposal procedure .
  • Page 10: Changing The Pco Cell

    CHANGING THE PCO CELL Remove the Unit Power Cable from the receptacle or ensure the unit isn’t powered . Remove the (4) Brass Thumb Nuts from the Unit Cover and Remove the Unit Cover and PCO Cells . Remove the (4) Screws holding the PCO Cells in plae and remove the PCO Cells from the Unit Cover .
  • Page 11 CHANGING THE PCO CELL Exchange the Old PCO Cells with the new PCO Cells and replace the (4) Screws that hold them in place . Replace the Unit Cover and PCO Cells in the duct and secure with the (4) Brass Thumb Nuts . Place the Unit Power Cable back into the receptacle or repower your unit .
  • Page 12 WARRANTY INFORMATION...