SCHEMATIC DIAGRAMS-10
PRIMARY POWER SUPPLY SECTION
1
BLACK
P9000
*
P9007:1F999028UL
*
P901
LIVE
P9007A
HOT
HOT
2
1
COLD
COLD
AC_CABLE
P9006A
NEUTRAL
P9006:1F999028UL
WHITE
2
*
3
*
4
5
U0041
PRIMARY POWER SUPPLY PC BOARD
BAPS-0217
C
(VH)
*
P9008A
NPLG-2P631
D9006
(VH)
1SS133
T9000
T9000
*
J9001
*
D9005
TA_7.5_DIM
1SS133
5
5
4
4
6
6
3
3
7
7
2
2
8
8
D9002
1
1
9
9
1SS133
D9003
E9100
1SS133
NEJITANSI_M3
D9009
1
2 3 4
D9008
1SS133
*
R9108
*
R9105
100K
100K
*
*
*
*
*
*
*
*
R9111
56
*
*
*
*
*
F9100
1
2
J9110
*
TA_7.5_DIM
*
*
*
R9201
100K
*
*
*
*
R9202
*
100
D
E
+7.0V
D9007
MTZJ5.1B
E9200A
NTM-1P233(M1969)
1
2 3 4
D9000
1SS133
JL901A
NSCT-7P878
1
MPOWER
2
APOWER1
3
APOWER2
D9001
4
+12V
1SS133
POFF
5
POFF
*
6
+SUB
1SS133
+SUB
7
GNDSUB
+12.2V
P1.5X7 L=20
0.04A
JL901:7J200606B15
*
GNDSUB
APOWER1
APOWER2
+12V
*
R9005
D9004
1SS133
+12.7V
+12V
*
MPOWER
TX-NR5007/NA5007,DTR-80.1 Transformer
Large Transformer NPT-1554
*
T901
1
2
1
S1
P9100
NPLG-2P632
(VH)
2
3
S2
S3
Small Transformer NPT-1582
*
T902
1
S4
1
2
P9200
2
S6
NPLG-2P632
(VH)
3
S7
F
G
D type
M type
C9108
Except J type
Except J type
T9000
C9115
D:NPT-1520JQ
C9201
M:NPT-1520GQ
D9100
C9001
D9200
D:2200/25V
J9001
M:2200/16V
J9100
J9101
F9100
J9102
D:12A-UL-ST6
J9109
M:6.3A-SE-TL250V
J:15A-T-ST6N1
J9110
P9008A
Except DC, Integra
Except DC, Integra
P9200,9300
Q9100
Q9200
R9005
27
27
R9100-9102
R9104
R9105
R9106
D=100
M=120
R9109
D=47
M=120
R9111
R9200
R9201
R9202
RL9100
RL9102
D,J
D,J
RL9200
BADG-0307
U0061
HOLDER PC BOARD
6
BAMEC-0308
7
E9200B
NTM-1P233(M1969)
NEJITANSI_M3
AMP+
8
1
2 3 4
9
10
11
AMP-
12
13
14
ASP
15
16
TUNER,
FAN,12V TRIGER
17
THE COMPONENTS IDENTIFIED BY MARK
REPLACE ONLY WITH PART NUMBER SPECIFIED.
VOLTAGE(MEASURED WITH VOLTMETER)IS DC VOLTAGE.(NO INPUT SIGNAL)
ELECTROLYTIC CAPACITORS(
)ARE IN
+
ALL CAPACITORS ARE IN pF/50WV UNLESS OTHERWISE NOTED.
EX) 030
3pF
330
33pF
331
CIRCUIT IS SUBJECT TO CHANGE FOR IMPROVEMENT.
4
CAUTION
DG,
SP RELAY
5
FOR CONTINUED PROTECTION
AGAINST FIRE HAZARD, REPLACE
6
ONLY WITH FUSE OF SAME TYPE
V
A
-VP
AND RATING INDICATED.
7
ATTENTION
8
CAUTIONF AFIN D'ASSURER UNE PROTECTION
FLAC
PERMANENTE CONTRE LES RISQUES
9
D'INCENDIE, REMPLACER UNIQUEMENT
PAR UN FUSIBLE DE MEME TYPE
V
A
ET CALIBRATION COMME INDIQUE.
PA-MC5501
H
12A/125V
T6.3AL250V
15A/125V
E9300
1
2 3 4
ARE CRITICAL FOR SAFETY.
F/WV
330pF
333
0.033
F
THIS SYMBOL LOCATED NEAR THE FUSE INDICATES
THAT THE FUSE USED IS SLOW OPERATING TYPE
FOR CONTINUED PROTECTION AGAINST FIRE FUSE
HAZARD,REPLACE WITH SAME TYPE FUSE. FOR FUSE
RATING REFER TO THE MAKING ADJACENT TO THE SYMBOL.
CE SYMBOLE INDIQUE QUE LE FUSIBLE UTLISE EST
A LENT, E POUR UNE PROTECTION PERMANENTE,N'UTILISER
QUE DES FUSIBLES DE MEME TYPE. CE DARNIER EST
INDIQUE LA QU LE PRESENT SYMBOL EST APPOSE.