Ventis twinfresh solar SA-60 User Manual

Single-room reversible energy regeneration ventilator

Advertisement

Quick Links

USER'S MANUAL
TwinFresh Solar:
• SA-60
• SA-60-M
• SA-60-L
• SA-60-2
• SA-60 Pro
• SA-60-2 Pro
• SA-60-M Pro
• SA-60-L Pro
Single-room reversible energy
regeneration ventilator

Advertisement

Table of Contents
loading

Summary of Contents for Ventis twinfresh solar SA-60

  • Page 1 USER’S MANUAL TwinFresh Solar: • SA-60 • SA-60-M • SA-60-L • SA-60-2 • SA-60 Pro • SA-60-2 Pro • SA-60-M Pro • SA-60-L Pro Single-room reversible energy regeneration ventilator...
  • Page 2: Table Of Contents

    www.ventilation-system.com CONTENTS Safety requirements Introduction Delivery set Designation key Main technical parameters Design and operating logic Mounting and set-up Connection and control Maintenance Troubleshooting Storage and transportation rules Manufacturer's warranty Acceptance certificate Seller's information Mounting Certificate Warranty Card...
  • Page 3: Safety Requirements

    SAFETY REQUIREMENTS • Read the user’s manual carefully prior to the operation and installation of the single-room reversible energy regeneration ventilator, hereinafter the ventilator. • Installation and operation of the ventilator shall be performed in accordance with the present user’s manual as well as the provisions of all the applicable local and national construction, electrical and technical codes and standards.
  • Page 4 www.ventilation-system.com VENTILATOR OPERATING SAFETY PRECAUTIONS Do not touch the controls with wet hands. Do not Do not wash the ventilator with water. Protect carry out the ventilator maintenance with wet the ventilator electric parts from water ingress. hands. Disconnect the ventilator from power supply Do not block the air duct when the ventilator is on.
  • Page 5: Introduction

    • TwinFresh Solar SA-60 Pro 11/16”) • TwinFresh Solar SA-60 (120 V/60 Hz) • TwinFresh Solar SA-60 Pro (120 V/60 Hz) • TwinFresh Solar SA-60-M from 475 mm (18 11/16”) up to 690 mm (27 • TwinFresh Solar SA-60-M Pro 3/16”)
  • Page 6: Designation Key

    www.ventilation-system.com DESIGNATION KEY TwinFresh Solar S -60- Battery unit _ - no battery unit is included Pro - battery unit is included in the delivery set Outer ventilation hood type _ - tapered metal ventilation hood for standard wall thickness 2 - metal ventilation hood for thin walls Rated air capacity [m /h] Controls availability...
  • Page 7 TWINFRESH SOLAR OVERALL DIMENSIONS Minimum air duct length Maximum air duct length Outer ventilation hood Ventilation grille Solar panel Battery unit Dimensions [mm TwinFresh Solar TwinFresh Solar TwinFresh Solar TwinFresh Solar TwinFresh Solar TwinFresh Solar (inch)] SA-60 SА-60-M SА-60-L SА-60 Pro SА-60-2 SА-60-2 Pro 300 (11...
  • Page 8: Design And Operating Logic

    www.ventilation-system.com DESIGN AND OPERATING LOGIC The ventilator consists of a telescopic air duct with adjustable length (inner part 3 and outer part 2), a fan 8, a ventilation grille 4, an outer ventilation hood 1 and a solar panel 12. The inner filter 9 and the ceramic regenerator 7 are located inside the inner air duct of the telescope 3.
  • Page 9 Ventilation grille filter. 1 item Strips intake air flow of dust and impurities. Prevents soiling of the regenerator. Rubber sealer. 1 item Doubles as a sealer and a vibration mount. Solar panel. 1 item Generates power supply for the ventilator. Solar panel holder.
  • Page 10: Mounting And Set-Up

    10 ( ’’) TwinFresh Solar SA-60-L 10 ( ’’) TwinFresh Solar SA-60-2 10 ( ’’)-110(4 ’’) TwinFresh Solar SA-60 Pro 10 ( ’’) TwinFresh Solar SA-60-M Pro 10 ( ’’) TwinFresh Solar SA-60-L Pro 10 ( ’’) TwinFresh Solar SA-60-2 Pro 10 ( ’’)-110(4...
  • Page 11 Fix the inner part of the telescope on inner side by means of the 3x25 Fill the gaps between the wall and the telescopic air duct with a screws from the delivery set. mounting foam. 3. Install the filter and the ceramic regenerator the telescopic air duct. Then install the fan, wire the ventilator and lay cables in the wall. 4.
  • Page 12 TwinFresh Solar SA-60 TwinFresh Solar SA-60-M TwinFresh Solar SA-60-2 TwinFresh Solar SA-60-L TwinFresh Solar SA-60-2 Pro TwinFresh Solar SA-60 Pro 1. Mark the fastening holes for the outer ventilation hood and drill 40 mm (19/16’’) deep holes for the 6x40 dowel. Ø6 (1/4’’)
  • Page 13 SOLAR PANEL MOUNTING 1. Mark the fastening holes for the solar panel and dill 40 mm deep holes for the 6x40 dowels. 378 mm 14 ⁄ " 72 mm 2 ⁄ " 2. Install the 6x40 dowels into the holes. 3.
  • Page 14 www.ventilation-system.com KVS-T POWER AND CONTROL UNIT MOUNTING. 1. Prepare a cavity in the wall for mounting of the power and control unit. Install a junction box. While mounting the power and control unit consider the supplied 2 3/4" cable length. A longer cable may be used on customer demand.
  • Page 15 5. Install the frame, the buttons and the plug in the reverse order. BATTERY UNIT MOUNTING (supplied only with the Pro models) Fasten the battery unit to the wall or to any other comfortable surface with dowels and screws. While mounting the battery unit consider the need to ensure service access.
  • Page 16 www.ventilation-system.com CONNECTION TO POWER MAINS AND CONTROL DISCONNECT THE VENTILATOR FROM POWER MAINS PRIOR TO ANY ELECTRIC INSTALLATION OPERATIONS. THE VENTILATOR MAINTENANCE AND INSTALLATION SHALL ONLY BE PERFORMED BY A PROFESSIONAL ELECTRICIAN QUALIFIED FOR UNASSISTED OPERATIONS WITH ELECTRICAL INSTALLATIONS UP TO 1000 V AFTER CAREFUL STUDY OF THE PRESENT USER’S MANUAL. THE RATED ELECTRICAL PARAMETERS OF THE VENTILATOR ARE STATED ON THE RATING PLATE.
  • Page 17 VENTILATOR OPERATION MODES Solar panel In the day time the ventilator is powered Control signal Power supply to via the solar panel. the ventilator (12 V) KVS- Switching unit TwinFresh Solar: • SA-60 ~230 V • SA-60-M • SA-60-L • SA-60-2 Solar panel In the night time or in...
  • Page 18 ExTERNAL WIRING DIAGRAM • TwinFresh Solar SA-60 Ventilator • TwinFresh Solar SA-60-M • TwinFresh Solar SA-60-L • TwinFresh Solar SA-60-2 Solar panel Power and control unit KSV-T to the solar KVS-T controller panel (blue) (brown) JMP1 11 12 13 14 15...
  • Page 19 ExTERNAL WIRING DIAGRAM Ventilator • TwinFresh Solar SA-60 Pro • TwinFresh Solar SA-60-2 Pro • TwinFresh Solar SA-60-M Pro • TwinFresh Solar SA-60-L Pro Solar panel Power and control unit KSV-T Battery unit to the solar panel (blue) (brown) KVS-T controller...
  • Page 20 www.ventilation-system.com CONNECTION OF SEVERAL VENTILATORS One KVS-T power and control unit is able to control many TwinFresh Solar ventilators. In case of connecting several TwinFresh Solar Pro ventilators each unit must be connected to its own solar panel or to its own battery unit. The connecting cables K1, K2, Kn (3х0,25/3xAWG 24) are not included in the delivery set.
  • Page 21: Maintenance

    MAINTENANCE DISCONNECT THE VENTILATOR FROM POWER SUPPLY PRIOR TO ANY MAINTENANCE OPERATIONS. Maintenance of the ventilator means regular cleaning of the ventilator surfaces of dust and cleaning or replacement of the filters. VENTILATOR MAINTENANCE 1. Fan maintenance (once per year). Take off the ventilation unit and clean the fan blades.
  • Page 22 www.ventilation-system.com Even regular technical maintenance may not completely prevent dirt accumulation on the regenerator assemblies. Subject the regenerator to regular cleaning to ensure its high heat recovery efficiency. Clean the regenerator with a vacuum cleaner at least once in a year. 3.
  • Page 23: Troubleshooting

    TROUBLESHOOTING POSSIBLE FAULTS AND TROUBLESHOOTING Fault Possible reasons Fault handling Make sure that the ventilator is properly connected No power supply. to the power mains and make any corrections, if The fan does not necessary. start up during the Turn the ventilator off. Troubleshoot the motor jam and ventilator start-up.
  • Page 24: Manufacturer's Warranty

    www.ventilation-system.com MANUFACTURER’S WARRANTY The manufacturer hereby warrants normal operation of the ventilator over the period of 24 months from the retail sale date provided the user’s observance of the transportation, storage, installation and operation regulations. Should any malfunctions occur during the ventilator operation through the manufacturer’s fault during the warranty period the user is entitled to elimination of faults by means of warranty repair performed by the manufacturer.
  • Page 25: Acceptance Certificate

    ACCEPTANCE CERTIFICATE Product Type The single-room reversible energy regeneration ventilator Model TwinFresh Solar _________________ Serial Number Manufacturing Date Is recognized as serviceable. We hereby declare that the product complies with the essential protection requirements of Electromagnetic Council Directive 2004/108/ EC, 89/336/EEC and Low Voltage Directive 2006/95/EC, 73/23/EEC and CE-marking Directive 93/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility.
  • Page 26: Warranty Card

    www.ventilation-system.com WARRANTY CARD Product type The single-room reversible energy regeneration ventilator Model TwinFresh Solar _________________ Serial number Manufacturing date Sales date Warranty period Sales company Seller’s seal ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ______________________________________________________________________________________________________...
  • Page 27 V62-3(SOLAR_SA-60)EN-02...

Table of Contents