RPB radex Instruction Manual

Airline filter
Hide thumbs Also See for radex:

Advertisement

Quick Links

Advertisement

loading
Need help?

Need help?

Do you have a question about the radex and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RPB radex

  • Page 3 ISO8573.1 Class 1 Air Quality. !DANGER! Do not connect the Radex Airline Filter to bottled air that does not have a pressure reducing valve that will reduce the air pressure to a maximum of 125 psig (860 kpa). Failure to comply with this warning could cause the Radex Airline Filter to explode, causing serious injury or death.
  • Page 6: Base Mount

    BASE MOUNT ASSEMBLY BASE MOUNT The base mount can be attached in two positions, wall mount or floor mount. To connect the base mount align the arrows on the base mount with the arrows on the filter, Fig 1.1 for floor mount, Fig 1.2 for wall mount.
  • Page 7: Pressure Regulator

    Fig 2.1 Fig 2.2 Fit the completed regulator assembly onto the top of the Radex Airline Filter lid (refer Fig 2.3). Once the regulator assembly has been tightened into position you can fit the pressure relief valve and tighten (refer Fig 2.4) ! WARNING ! The pressure relief valve must be connected to protect the Radex Airline Filter from over pressurizing.
  • Page 8: Inlet Connection

    INLET CONNECTION The Radex Airline Filter has a 1” NPT inlet. It is advised to connect a ball valve close to the inlet so the unit can be shut off for servicing. Connect inlet fittings and tighten. Once the Radex Airline Filter is completely assembled and connected to compressed air open supply line and check fitting for any air leaks, tighten accordingly.
  • Page 9 Thread the completed 04-964 Six Outlet Manifold in to filter lid and tighten (fig 4.3) Fig 4.1 Fig 4.2 Fig 4.3 Thread the 04-916 Pressure Relief Valve into the lid and tighten. !WARNING! The pressure relief valve must be connected to protect the Radex Airline Filter from over pressurizing. Fig 4.4 Fig 4.5...
  • Page 10 Thread the 04-963 Pressure Gauge and 04-966 1” NPT Connector into the 04-962 Super High Flow Regulator and tighten. (fig 4.6) Now thread the completed Regulator into the INPUT port on the body of the Radex Filter Unit and tighten.
  • Page 11 Connect air fittings that meet the requirements of OSHA for respirable air. The inlet thread size is 1” NPT. All connections should be sealed using liquid thread sealant. If the Radex Airline Filter is hard piped an isolation valve must be used to enable depressurisation for servicing.
  • Page 12: Filter Cartridge Replacement

    • Presence of moisture at the outlet fittings. • Large pressure drop across the filter. Shut off the air supply to the Radex Airline Filter and drain all air from the body by opening the drain tap. Remove the bolts from the lid and separate the lid from the body.
  • Page 13 LID BOLTS, ORINGS The Radex Airline Filter lid bolts should be checked to ensure that they are tight. The lid bolts (04-920) should be replaced when replacing the filter cartridge. The recommended tightness for the lid bolts is 10ft.lbs. Check the orings (04-919) and replace if...