Download Print this page

Millbank Talisman TAL/DLS5/3 Installation Manual

Dynamic loop amplifier systems

Advertisement

Quick Links

TALISMAN
DYNAMIC LOOP AMPLIFIER SYSTEMS
_______________________________

INSTALLATION GUIDE

Publication Code TAL-DLS-3_TIG Issue 3
TAL/DLS1/3
TAL/DLS5/3
Part No. 7157106
Part No. 7157206
PLEASE NOTE: THIS MANUAL AND THE NOTES CONTAINED HEREIN, IS COPYRIGHT AND MAY NOT BE
REPRODUCED EITHER WHOLLY OR IN PART, IN ANY WAY WHATSOEVER, WITHOUT WRITTEN CONSENT
OF FEDERAL SIGNAL LIMITED.
PUBLICATION OF THIS INFORMATION DOES NOT IMPLY ANY AUTHORITY OR LICENCE FOR THE
UTILISATION IN ANY MANNER, IN ANY COUNTRY, OR ANY PATENTED OR REGISTERED DESIGN
FEATURES, MECHANICAL, ELECTRICAL OR AESTHETIC.
MILLBANK ELECTRONICS
is part of:
F
S
L
EDERAL
IGNAL
TD
Signal House, Charter Way, Hurdsfield Industrial Estate, Macclesfield, Cheshire, SK10 2NF, England
TEL: +44 (0) 1625 66 66 00
FAX: +44 (0) 1625 611 352
e-mail: millbank@fedsig.co.uk
In the interest of product improvement we reserve the right to change specification or design without notice.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Talisman TAL/DLS5/3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Millbank Talisman TAL/DLS5/3

  • Page 1: Installation Guide

    OF FEDERAL SIGNAL LIMITED. PUBLICATION OF THIS INFORMATION DOES NOT IMPLY ANY AUTHORITY OR LICENCE FOR THE UTILISATION IN ANY MANNER, IN ANY COUNTRY, OR ANY PATENTED OR REGISTERED DESIGN FEATURES, MECHANICAL, ELECTRICAL OR AESTHETIC. MILLBANK ELECTRONICS is part of: EDERAL IGNAL...
  • Page 2 If it is necessary to re-pack the equipment for onward shipping or returning to Millbank for service PLEASE ENSURE THAT THE ORIGINAL PACKING OR EQUIVALENT IS USED.
  • Page 3: Installation

    Talisman III Dynamic Loop Amplifier Systems (TAL/DLS1/3 & TAL/DLS5/3) INSTALLATION Precautions IMPORTANT: Before operating the PAC Amplifier please take note of the following points: 1.1.1 Ensure that the equipment is connected to a suitable mains supply. The equipment is supplied configured for 230V 50/60Hz AC operation.
  • Page 4 AFILS for booking offices, bank tellers etc. The MILLBANK Dynamic Loop System The dual purpose design allows for assisted listening of the hearing impaired and for applications such as commentary systems in museums and art galleries.
  • Page 5 The unique Millbank Electronic design incorporates the results of many years of operational experience in this field and offers superior performance. Features include: Dual purpose design For the hearing impaired, especially contoured frequency curve.
  • Page 6 Talisman III Dynamic Loop Amplifier Systems (TAL/DLS1/3 & TAL/DLS5/3) CURRENT / CONDUCTOR GRAPH Only a single turn loop of cable is normally required. CONDUCTOR TYPE COPPER AREA 1/0.8mm 0.5mm sq. This assumes that the receiver is 1.5 metres above or 7/0.2mm 0.22mm sq.
  • Page 7 Talisman III Dynamic Loop Amplifier Systems (TAL/DLS1/3 & TAL/DLS5/3) CHECK-LIST FOR SYSTEM DESIGN USING TAL/DLS Refer also to setting up procedure on following pages Before starting you will need the following: a) Tape measure (at least 10m long). b) Magnetic field strength meter. c) AFILS receiver (headphones and hearing aid recommended).
  • Page 8: Controls And Connections

    To avoid electric shock hazard, do not expose this appliance to rain or moisture. High Voltage T3,15L 250V No user serviceable parts inside, refer servicing to qualified personel. Designed by Millbank on behalf of Federal Signal Ltd. Manufactured in R.O.C. TAL DLS1 Dynamic Loop Amplifier System Federal Signal Ltd...
  • Page 9 To avoid electric shock hazard, do not expose this appliance to rain or moisture. T3,15L 250V Federal Signal Ltd No user serviceable parts inside, refer servicing to qualified personel. Signal House Designed by Millbank on behalf of Federal Signal Ltd. Manufactured in R.O.C. Hurdsfield Industrial Estate Macclesfield Cheshire England SK10 2NF...
  • Page 10: Setup Procedure

    Talisman III Dynamic Loop Amplifier Systems (TAL/DLS1/3 & TAL/DLS5/3) SETUP PROCEDURE Connections 6.1.1 Loop Screw connections are provided for connection of the wire loop. 6.1.2 Microphones All connections to the microphone inputs are by 5 pin180° DIN connectors, which are supplied with the equipment.
  • Page 11 Talisman III Dynamic Loop Amplifier Systems (TAL/DLS1/3 & TAL/DLS5/3) Setup 6.2.1 Set the response switch to the desired frequency response, this should be set to 5KHz for hearing impaired applications. 6.2.2 Set the mode switch to AGC (Automatic Gain Control) or the limiter position. In AGC mode (hearing impaired applications), the AGC LED should flicker off during pauses in speech by setting the input level using the input level controls located on the front panel.
  • Page 12 This RGA number should then be referenced on every related correspondence. If it is necessary to re-pack the equipment for onward shipping or returning to Millbank for service or repair, PLEASE ENSURE THAT THE ORIGINAL PACKING OR EQUIVALENT IS USED. IN CASE OF SERVICE REQUIREMENTS PLEASE CONTACT YOUR SUPPLIER...
  • Page 13 Talisman III Dynamic Loop Amplifier Systems (TAL/DLS1/3 & TAL/DLS5/3) Document Change History Issue Details Date First Issue Mar 00 Updated to include new standard clauses and company May 01 details Updates section 6 to include wiring details and referral to Dec 01 additional programming features Jumper setting investigated and recorded –...

This manual is also suitable for: