Network Setup - Panasonic TH-80LF50ER Operating Instructions Manual

Hide thumbs Also See for TH-80LF50ER:
Table of Contents

Advertisement

Network Setup

Make the various settings to use the network function.
Setup
MULTI DISPLAY Setup
Set up TIMER
PRESENT TIME Setup
Network Setup
Menu Display Duration
Menu Transparency
Network Setup
Save
DHCP
IP address
Subnet mask
Gateway
Port
LAN Speed
Network ID
Control I/F Select
MAC address
Save
Save the current network Setup. Each value set for
DHCP, IP address, Subnet mask, and Gateway will be
saved. If "NG" is displayed, check the same IP address
is not used within the same network.
DHCP (DHCP client function)
To obtain an IP address automatically using a DHCP
server, set this to "On". If DHCP server is not used, set
this to "Off".
IP address (IP address display and setting)
Enter an IP address if DHCP server is not used.
Subnet mask (Subnet mask display and setting)
Enter a subnet mask if DHCP server is not used.
Gateway (Gateway address display and setting)
Enter a gateway address if DHCP server is not used.
Notes:
• To use a DHCP server, make sure the DHCP server is started.
• Contact your network administrator for details on settings.
44
DHCP, IP address, Subnet mask, and Gateway settings
2/2
1
Set DHCP.
When "Off" is selected, IP address and other settings can be set
manually.
2
Select the item and press
15 S
20
3
Enter an address.
IP address
4
Select "Save" and press
Off
192.168. 0. 8
Port setting
255.255.255. 0
1
Select "Port" and press
192.168. 0. 1
2
Enter a port number.
1024
Port
Auto
0
RS-232C
--:--:--:--:--:--
1
Use
I
192.168.
0.
8
2
Use
3
Press
Pressing
1
Use
I
01024
2
Use
Press
3
Pressing
Port
Set the port number used for command control.
The available setting range is 1024 – 65535.
When the PJLink™ protocol is used, the port setting is
not necessary.
LAN Speed
Set the connection speed of the LAN environment.
Select the value from Auto, 10 Half, 10 Full, 100 Half or
100 Full.
Network ID
Set the ID to identify this unit.
The available setting range is 0 – 99.
Control I/F Select
Set whether to control with RS-232C (serial) or LAN.
When "LAN" is set, power indicator lights orange under
the condition of power "Off" with remote control (stand-
by state).
Note:
When the power indicator lights up orange, 6 W of power
is being consumed.
MAC address
Display the MAC address of this unit. However, the MAC
address is not displayed when the "Control I/F Select" is
set to "RS-232C".
.
to select a digit.
to change a number.
.
will cancel the address change.
.
.
to select a digit.
to change a number.
.
will cancel the port number change.