8
Select the item to set, and set to
[
].
▲ ▼ → ◄ ► (or
• COOL Temperature rising direction
• HEAT Temperature falling direction
9
Set the time to return to the set
temperature.
▲ ▼ →
• 10 to 240 min (by the 10 min)
10
Set the temperature.
▲ ▼ →
Setting range
• COOL/DRY : 18 °C to 30 °C
• HEAT : 16 °C to 30 °C*
* The upper limit temperature of gas heat
pump air conditioner is 26 °C.
 To set in series
Note
 To operate only when energy can be saved, select [Return type] in step 8.
When [Return type] is set to [Saving], this functions only when the temperature set in step
10 saves more energy than the changed temperature.
e.g. When Cool 26 °C is set and the temperature is changed to 28 °C
• [Saving]: Keeps 28 °C
• [Normal]: Returns to 26 °C
 The temperature range that can be set varies depending on the model.
) →
(Press 2 times to fi nish.)
Repeat from step 7 without pressing
.