Mains cord IN
OTC gets supply voltage
OTC resets, Initialise IO pins
Reset Audio=high
Read NVM identification
enable watchdog
start time extraction
start P50 recording
start EPG loading
Stand-by
Standby bit = off
Ambient light ON
Trapped Startup 1
Put Stand-by line LOW
CPU GO becomes HIGH
Set STBYEN,VCCON,PFCON = 1
Only FHP (opt 2, 8)
Keep sound amplifiers muted with
sound enable = high
+5V and +8V is switched on
+8V and +5V get their nominal level,
detected by the OTC
activate protection algorithms for +8V and +5V and
I²C (start I²C protection the moment the component
is initialised).
Trapped Startup 2
Read rest of NVM information
Initialize HIP: IF, source selection, 2fh input, video
processing
Switch on the syncoutput: set_syncout_tristate= off
Initialize tuner
Initialize 3D Combfilter
or Initialize Columbus
Initialize PICNIC + screen info
Initialize rest of PIP/DW module
Start TXT acquisition
and time extraction
Reset Audio = low
and Initialize MSP
Initialize EBILD
Screen type
Start up LCD
Initialize PDP FHP
opt 3,4,5,6
opt 2,8
Figure 5-3 Stepwise start-up
ialize PDP FHP
Set Fixed settings
Set default settings
yes
Stand by bit set?
PDP ON
PDP: PDP ON =1
Wait 200 msec
Power OK (POR OTC)?
Wait 200 msec
Read CNDC
CNDC = 4 ?
Ebild/ Power ON
Trapped Startup 3
Output blanking: OFF
Semi stand by
PDP: ADEN = 1
Figure 5-4 Stepwise start-up part 2: Initialise FHP
Service Modes, Error Codes, and Fault Finding
OUT
Tact switch
OFF
Stand-by bit = OFF
400msec>t>200msec
Initialize PDP SDI
E_14620_048.eps
opt 0,1,7
START
no
no
no
Time out 5 sec?
yes
no
yes
no
yes
Time out 5 sec?
yes
Trapped Startup 4
Goto protection
Trapped Startup 4
PDP ON
E_14660_002.eps
150704
Ebild: POWER OFF
Trapped Startup 3
Semi stand by
Figure 5-5 Stepwise start-up part 2: Initialise SDI (*)
Notes (*):
When the TV is in stepwise mode and, due to stepping-up,
a protection is activated, the TV will really go into protection
(blinking LED). The TV will not leave the stepwise mode
however. If state X is the state where the TV went to
protection, stepwise start-up will return to state X-1. At
state (X-1) diagnostic measurements can be performed.
Also, in the short time the TV is in state X but not yet in
protection, you can also do some measurements.
Stepwise start-up can NOT be used for Samsung displays
(SDI). The TV will not react in a proper way, due to other
timing specifications.
5.4.4
How To Connect
This is described in the chassis fault finding database in
ComPair.
170504
Figure 5-6 ComPair interface connection
5.4.5
How To Order
ComPair order codes (EU/AP/LATAM):
Starter kit ComPair32/SearchMan32 software and
ComPair interface (excl. transformer): 3122 785 90450.
ComPair interface (excl. transformer): 4822 727 21631.
Starter kit ComPair32 software (registration version): 3122
785 60040.
Starter kit SearchMan32 software: 3122 785 60050.
ComPair32 CD (update): 3122 785 60070 (year 2002),
3122 785 60110 (year 2003 onwards).
SearchMan32 CD (update): 3122 785 60080 (year 2002),
3122 785 60120 (year 2003), 3122 785 60130 (year 2004).
ComPair firmware upgrade IC: 3122 785 90510.
Transformer (non-UK): 4822 727 21632.
Transformer UK: 4822 727 21633.
ComPair interface cable: 3122 785 90004.
ComPair interface extension cable: 3139 131 03791.
ComPair UART interface cable: 3122 785 90630.
Note: If you encounter any problems, contact your local
support desk.
FTP2.4E AA
START
Initialize PDP SDI
Max 3.04 sec after 5V and 8V =OK
Set Fixed settings
PDP ON
Ebild: POWER ON
Stable LVDS
Wait 200 msec
Power OK (POR OTC)?
no
Time out 5 sec?
Stby bit set?
yes
Goto protection
no
Ebild/ Output blanking: OFF
Trapped Startup 4
PDP ON
TO
UART SERVICE
CONNECTOR
PC
VCR
Power
9V DC
E_06532_021.eps
5.
EN 17
no
yes
E_14660_003.eps
150704
TO
I 2 C SERVICE
CONNECTOR
I 2 C
180804

Advertisement