Wiring Diagram; Specifications; Replacement Parts; Service Hints - Vantage Hearth VFS32NRK Owner's Operation And Installation Manual

Unvented (vent-free) gas fireplace
Table of Contents

Advertisement

Model VFS32NRK
• Rating (Variable): 17,000/25,000 Btu/Hr
• Type Gas: Natural Gas Only
• Ignition: Piezo
• Pressure Manifold: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 10.5" W.C., Minimum* 5" W.C.
• Shipping Weight: 122 lbs.
* For input adjustment
Model VFS36NRK
• Rating (Variable): 20,000/33,000 Btu/Hr
• Type Gas: Natural Gas Only
• Ignition: Piezo
• Pressure Manifold: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 10.5" W.C., Minimum* 5" W.C.
• Shipping Weight: 122 lbs.
* For input adjustment
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
Contact authorized dealers of this product.
If they can't supply original replacement
part(s), call FMI PRODUCTS, LLC at
1-866-328-4537.
When calling, have ready

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low for
propane/LP unit
You may feel your gas pressure is too low. If
so, contact your local gas supplier.
126360-01A

WIRING DIAGRAM

SPECIFICATIONS

REPLACEMENT PARTS

www.fmiproducts.com
Thermopile
Model VFS32PRK
• Rating (Variable): 17,000/25,000 Btu/Hr
• Type Gas: Propant/LP Only
• Ignition: Piezo
• Pressure Manifold: 7.9" W.C.
• Inlet Gas Pressure (in. of water)
Maximum 13" W.C., Minimum* 11" W.C.
• Shipping Weight: 122 lbs.
* For input adjustment
Model VFS36PRK
• Rating (Variable): 20,000/33,000 Btu/Hr
• Type Gas: Propant/LP Only
• Ignition: Piezo
• Pressure Manifold: 7.9" W.C.
• Inlet Gas Pressure (in. of water)
Maximum 13" W.C., Minimum* 11" W.C.
• Shipping Weight: 122 lbs.
* For input adjustment
• your name and address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• type of gas (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to
the factory.

TECHNICAL SERVICE

You may have further questions about
installation, operation, or troubleshooting.
If so, contact FMI PRODUCTS, LLC at
1-866-328-4537. When calling please have
your model and serial numbers of your
heater ready.