General requirement:
1. 10 arcs for positive and negative polarity for unit "on" and "off" for 1kV incremental steps.
2. Component or mechanical damage is not allowed. No loss of fixed stored data (stored in EEPROMs).
3. Hang-ups and malfunctions are allowed, as long as the customer can "recover" from the hang-up by
pressing the Standby or ON/OFF button of the set.
4. Failures that disappear only by unplugging the AC mains cord and/or power sources are not acceptable.

Environmental Condition

2.6
The environmental condition requirements and test method is according to UAN-D1590.
Ambient temperature
Apparatus acc. to spec.
Vibration test (acc. IEC 60 068/2/6) : operational vibration test to be proceeded in operating position of the
set.

Quality

2.7
PQR-class:
Lifetime:
Tested According to:
Measured According to:
-
2
3
Tang Bing
NAME
CHECK
Philips Electronics (China) Ltd.
No.12 ShiHua Road, FuTian Free Trade Zone,
ShenZhen, China
: max. 40 ° C - all climates
: +5 to + 35 ° C
class 2 according to BLC V&MA PQR handbook V2.1 (2006-10-02)
7 years
General Test Instruction UAN-D 1591
UAN_L 1059 unless otherwise stated
AZ127/320/328/329