Page 4
Warning! Do not open device while it is energized! Hazardous voltage is present inside the device. Disconnect all connectors before opening! Page: Company: Device: Document: Code: Version: Date: Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 V1 28.05.2015...
Page 5
Warning! If device is damaged disconnect it from power supply! Send it to the manufacturer for inspection. Warning! Connect to earth before attaching power supply! Company: Device: Document: Code: Version: Date: Page: Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 V1 28.05.2015...
There is possibility to use additional redundancy power supply. Housing is made from inox and is intended for mount on standard 19"rack. Page: Company: Device: Document: Code: Version: Date: Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 V1 28.05.2015...
Hardware settings For proper functioning of that board some settings must be done: RS485 bus termination and stabilisation baud rate Page: Company: Device: Document: Code: Version: Date: Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 V1 28.05.2015...
Page 9
RS485 stabilisation Description Picture 3: RS485 BUS schematic Switches at the upper side of connector: BAUD rate BAUD rate Switch Interface 5 Interface M Interface L Company: Device: Document: Code: Version: Date: Page: Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 V1 28.05.2015...
Page 10
B and A line. Try to switch A and B wires. See http://en.wikipedia.org/wiki/RS-485 for detailed information. Connector pin table MSTB - (A) + (B) Description Picture 4: RS485 interface board appearance with switch settings Page: Company: Device: Document: Code: Version: Date: Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 V1 28.05.2015...
For proper functioning of that board, optic logic must be set: Fiber optic logic settings Switch SW1 Light in idle state Positive logic OFF ON OFF ON ON OFF ON OFF Negative logic Company: Device: Document: Code: Version: Date: Page: Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 V1 28.05.2015...
Protective earthing wire must be terminated with tinned copper ear terminal. The prescribed bending radius of the optical fibre cables must be observed. Page: Company: Device: Document: Code: Version: Date: Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 V1 28.05.2015...
If single mode fiber optic interface is used, do not look into the laser beam. MAINTENANCE The device is maintenance-free. Disconnect power supply before cleaning it. Use moist cloth. Do not use liquids. Company: Device: Document: Code: Version: Date: Page: Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 V1 28.05.2015...
Wave lenght 50/125 μm, 62,5/125 μm, 100/140 μm, 200 μm Fiber size Optical output power -18 dB -24 dB Reciver sensitivity Laser class I (IEC 60825-1) Page: Company: Device: Document: Code: Version: Date: Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 V1 28.05.2015...
Page 17
Material inox Enclosure 4x M6 screw 19" rack Mount type Class Overvoltage category Receiveing yellow LED marked Rx Communication indicator Tranmitting green LED marked Tx Company: Device: Document: Code: Version: Date: Page: Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 V1 28.05.2015...
- power supply cable with „schuko“ plug, 2 m - RS232 cable to PC (state the lenght up 15 m) - fiber optic cables (state the lenght) Company: Device: Document: Code: Version: Date: Page: Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 V1 28.05.2015...
Need help?
Do you have a question about the CMU 200 / HACx2 . 485x1 . FOTx39 – 12 and is the answer not in the manual?