MANUAL
(revision 8/2015)
2015

Advertisement

Table of Contents
loading

Summary of Contents for UWT AV1

  • Page 1: Dive Computer

    dive computer MANUAL (revision 8/2015) 2015...
  • Page 2: Table Of Contents

    CONTENTS WARNING ..................................... 4 AV1 DIVE COMPUTER GENERAL DESCRIPTION ..................... 5 2. MAIN PARAMETERS AND DISPLAY FUNCTIONS ....................6 2.1 C ..................................6 ONTROL UTTONS 2.2 P ..................................... 6 OWER UPPLY 2.3 U ................................7 NITS OF MEASUREMENT TURNING ON AND OFF ............................8 4.
  • Page 3 7.2 D ............................. 38 IRECTION IXATION ARKING 8. AV1 MANAGER MODE .............................. 38 9. GAME ....................................40 10. TECHNICAL CHARACTERISTICS AND SERVICE CONDITIONS ..............40 11. AV1 SERVICING ................................ 41 12. WARRANTY ................................41...
  • Page 4: Warning

    WARNING Decompression meter firmfare calculates theoretical tissue saturation with inert gases based on a mathematical model. This model was made thanks to a variety of experimental data with the latest decompression theory developments. Nevetherless, using the dive computer, as well as decompression tables cannot guarantee complete protection against Decompression Decease (DD).
  • Page 5: Av1 Dive Computer General Description

    1. AV1 DIVE COMPUTER GENERAL DESCRIPTION AV1 dive computer (further – AV1) shows all important dive parameters and decompression information on the screen.
  • Page 6: Main Parameters And Display Functions

    Main screen will happen in 5 minutes. In Surface mode buttons are set to maximum sensitivity. You can set AV1 in such a way that AV1 could automatically decrease buttons’ sensitivity in Dive mode in order to avoid occasional buttons’...
  • Page 7: Units Of Measurement

    Operation time with fully charged battery is about 10 hours. If you don't use AV1 for a long time, charge it at least once in 2 (two) months. It will prolong battery life. With full battery discharge all the information (current settings, current tissue saturation) will be lost! Don’t take too much effort when screwing the cap!
  • Page 8: Turning On And Off

    CNS level taking into account your surface interval. AV1 will automatically switch to Dive mode within 10 seconds of 2 meters' submerging. AV1 will also automatically switch from Dive mode to Surface mode, if the depth is less than 1(one) meter within 2 minutes.
  • Page 9: Switch Sp

    ->Switch SP (only in CCR mode) manual switching between Low, High and Deco Setpoints. Choose the required Setpoint with button Next and confirm with button ОК. ->Dive setup -> Entry to the submenu of dive mode settings ->Edit mix Gas list editing. Here you can add gases into active gases' list which will be available in Select mix menu item.
  • Page 10 Accordingly, you can now set you diluent in CCR mode as active CCR gas, as well as all bailout gases as OC ones. In this case, decompression and TTS in CCR mode shall be calculated based on diluent, and in the case of switch to OC automatically calculated based on OC gases and will offer the gas from the list of OC gases.
  • Page 11 CCR". Additional depth level is required, if before ascending decompression time some horizontal route is supposed, for example, in the overhead environment, or to the buoy. CAUTION!!! This level is taken into account if it is shallower than the current depth.
  • Page 12  Red > 10%  Flashing red square with a cross> 1% Starting from Firmware 2.7b version AV1 eCCR controller supports the standard tempstick for Inspiration Vision. Through the same interface C02 sensor can be connected in the future. ->Setup SP (only in CCR mode) Editing High, Low and Deco Setpoints and Depth of AutoSwitching.
  • Page 13: Select Mix

    ->AutoSwitch SP (only in CCR mode) Turning On / Off AutoSwitch of Setpoints. By pressing ON for this SubMenu AutoSwitch of Setpoints (from Low SP to High SP, and vice versa) will be made when crossing the depth level preset in SW at SubMenu in ->Setup SP.
  • Page 14: Switchoc/Ccr

    PO2 sensors' correctness control mode during the dive: PO2 values at the current depth are displayed at the bottom of AV1 screen in case of flushing the loop with diluent or (up to 10 meters inclusive) with oxygen. The function works on all AV1 products in CCR mode.
  • Page 15 ATTENTION! Date and time are NOT set automatically in the dive computer! Set date and time before the first dive! In case if the dive computer is rarely used, please, check date and time during each charging! ->Up/Download (only in Surface Interval mode) Switching to DFU – Device Firmware Update mode or Logbook Downloading.
  • Page 16 ->Display mode (only in Surface mode) Switching betweem Metric and Imperial units of depth and temperature measurement (meters and Celcius degrees or feet and Farenheit degrees). Переключение между метрическими и имперскими единицами измерения глубины и температуры. Switching between fields is done with  button, saving with OK. ->Language (only in Surface mode) Choosing the language.
  • Page 17: Diveplan

    Available setting options: 30sec – 60sec – 2min – 10min – 30min – 60min. Default setting: 60sec. In PO2 cells control moe or in eCCR mode AV1 will be making sound signal for 1 min. and flashing alternately with red and green HUD L.E.D. prior to automatic switch off.
  • Page 18: Logbook

    ->Logbook (only in Surface Interval mode) logbook browsing. Brief information, graph, complete information in table mode. Depth profile (blue), temperature profile (green) and decompression ceiling (red) are presented in a graphic way. Switching between modes is done by simultaneous pressing of 2 buttons. In brief information and in graph modes switching between dives is done by pressing Next и...
  • Page 19 Possible value range1-10. 1 – the lowest level of backlight intensity; 10 – the highest level of backlight intensity. The higher backlight intensity, the faster battery discharging. AV1 battery capacity at minimum brightness – not less than 20 hours. At maximum one – 10 hours.
  • Page 20: Switch Screen

    ->Switch screen Sets the screen view: Main, Alternative (only in Dive Mode) or Compass. Switching between screens in Dive Mode is made by pressing both buttons. See in detail Dive Mode. ->DiveSimulator Turning On/Off Dive Simulator Mode. «Dive» Depth (only in Surface Interval mode) adjusting.
  • Page 21: Calibrate O

    See in detail – Oxygen Cells' Control. 5. MAIN OPERATION MODES If your AV1 is in Sleep mode, nothing is displayed on the screen. Nevertheless, the computer keeps monitoring ambient pressure and calculates desaturation. For switching from Sleep mode to Surface Interval mode – press subsequently left, then right buttons.
  • Page 22: Surface Interval Mode

    5.1 Surface Interval mode By pressing MENU you move to AV1 Main menu. By pressing MIX you move to SubMenu for selecting current gas. When Surface Interval mode is activated, the following main settings will be displayed on the screen: ...
  • Page 23: Dive Mode

     Violation warnings of the last dive (if any happened). 5.2 Dive mode In Dive mode AV1 has two options of information indication on the screen: Basic and Alternative screens. Both screen options can be turned on both in OC and in CCR mode.
  • Page 24 FAST - ascending speed higher than 10m/min. System warning, stored in the logbook. Not bestmix – it is recommended to change the gas. There is gas in the list of active gases which better than the current one. Gases are compared by MOD. The gas / gas mix with maximum MOD not higher than current depth is considered to be the best mix.
  • Page 25: Gauge Mode

    Basic Compass screen in Dive Mode: Basic eCCR controller screen: 5.3 Gauge mode In Gauge mode AV1 shows depth, dive time, timer, reflects maximal and average depth, temperature, ascending/descending speed. In Gauge mode neither NDL, nor decompression is calculated! and CNS control is disabled.
  • Page 26: Gauge Mode Turning On/Off

    You are making ALL your dives in Gauge mode at your own risk! IMPORTANT! Upon diving in Gauge mode, do NOT dive with AV1 as decompression meter earlier than 48 hours since the last dive in Gauge mode !!! Otherwise incorrect tissues' saturation probabilty is very high. As a consequence, you will be under high risk of decompression decease! 5.3.2 Average Depth calculation and Dive Segment Time...
  • Page 27: Recreational Mode

    5.4 Recreational mode Switching AV1 to Recreational mode is possible only on surface. Settings are simplified in the Recreational mode at maximum. Switching from Recreatonal to Closed Circuit is turned off. It is possible to use only one gas –...
  • Page 28 Deoending on dive condtions non-obligatory safety stops in the range of 6-9-12 meters will be recommended. When reaching the safety stop depth, safety stop countdown timer will automatically swith on. When decompression levels are violated, AV1 will calculate all required safety stops.
  • Page 29: Dive Simulator Mode

    5.5 Dive Simulator mode With Dive Simultator you have a chance to learn AV1 operation in all the modes staying onshore. In Dive Simulator mode dives are not recorded into the logbook, current saturation is not changed. Dive depth change can be simulated manually by simultaneous pressing of the buttons.
  • Page 30: Po Cells Control Mode

    Dive Planning is made on AV1 current settings: At any moment of the dive the whole diveplan with all the forthcoming decompression stops can be looked through! 5.7 PO Cells Control mode (Only for AV1F and AV1 eCCR controller )
  • Page 31: Pinout Scheme

    Switching to deco setpoint is possible only in manual mode. In this mode automatic dive computer switch off on surface is not available (switched off). Below is example of PO Cells Control mode screen: 5.7.1 Pinout Scheme...
  • Page 32: Calculation

    Oxygen cells. 5.7.3 Alarm Warnings AV1 with Fischer connector has a built-in buzzer. Red and green L.E.D. built-in the HUD are also activated via Fischer connector. If calculated PO differs from the preset Setpoint by not more than 0.2, green indicator is on.
  • Page 33: Po2 Control Mode Turning On

     Switch AV1 into CCR mode (See Menu item ->switch OC/CCR ); In this mode ->CellsControl SubMenu becomes available.  Enter ->CellsControl SubMenu to set required Oxygen cells ON;  Save setting by pressing YES :  With at least one Oxygen cell activated, AV1 will automatically offer to calibrate.
  • Page 34: Oxygen Cells Calibration

     when at least 1 (one) Oxygen cell is activated by pressing ->CellsControl in the Main Menu;  when AV1 is turned on, the Oxygen cells' cable is activated, CCR mode is chosen, and at least 1 (one) Oxygen cell is activated by pressing ->CellsControl in the Main Menu;...
  • Page 35: Eccr Controller

    When calibration is finished, press OK to save, or, if required press Repeat to repeat. 6. eCCR CONTROLLER ECCR AV1 controller manages the solenoid and supports the preset setpoint based on the information received from Oxygen cells. 6.1 eCCR AV1 Controller Functions Oxygen is supplied by the solenoid in cycles: every 5 seconds –...
  • Page 36: Power Supply System

    6.2 Power supply system eCCR AV1 (ver 1) controller, unlike AV1 dive computer, does NOT have a built-in accumulator. Power is supplied from external power sources. controller has two built-in independent power sources: basic B1 –...
  • Page 37: Built-In Compass

    7. BUILT-IN COMPASS AV1 has a built-in magnetic compass with three-axes accelerometer for complete values’ compensation based on angularity of the compass body. You can use the compass both in the Gauge and in the Recreational modes. Compass operates both in the Surface and Dive modes.
  • Page 38: Calibration

    For calibration proceed with the following:  Switch AV1 to Compass Calibration mode (see Menu item);  Rotate AV1 in all 3 (theree) axes. Try to make 2 rotations round each axis within 4-5 seconds;  Save the result by pressing the left button.
  • Page 39 3. switch AV1 to Update mode: System setup -> Up\Down load -> OK AV1 will switch to DFU mode (Device Firmware Update mode). Windows will identify AV1 as a standard HID-device and automatically install all the required drivers. 4. launch AV1 Manager;...
  • Page 40: Game

    8. Updating process will take 1-3 minutes. When finished, press Return, switch the USB cable off; 9. Press two buttons simaltenously to exit DFU mode and to reload AV1. 9. GAME AV1 dive computer has a built-in game – “Python”.
  • Page 41: Av1 Servicing

     If lowbat is on the scree, charge the battery;  When diving with a power discharged AV1, your AV1 can switch off itself during your dive. 12. WARRANTY AV1 dive computers and controllers are warranted for purchasers from authorized dealers/distributors or the manufacturer.
  • Page 42 The manufacturer takes the exclusive decision about any warranty claim and about further repair or replacement. Exclusions:  AV1 misuse and/or negligence of operation and service manufacturer recommendations is NOT covered by the warranty;  Use of inappropriate wear and spare parts is NOT covered by the warranty;...