TH5f10D NON-PROGRAMMABLE
THERMOSTAT
Installer Setup Numbers and Settings
Table 3. Installer
setup numbers
and settings.
Installer Setup
Number
Installer
Setup Name
1
System Type
2
Changeover
Valve-O/B
May
not appear.
Terminal
Energized
in
See Note
a
Heating
or Cooling
(Heat
Pumps
only)
3
Fan Control
in Heating
May
not appear.
See Note
b
5
Heating
Cycle
Rate
in
May
not appear,
cycles
per hour (cph)
See Note
c
9
Compressor Cycle Rate
May not appear,
in cycles per hour (cph)
See Note d
12
System Setting
0--Manual
changeover (Factory
Setting)
(Heat, Off, Cool)
May not appear.
Adjustment
See Note e
1--Auto
changeover (Heat, Off, Cool, Auto)
2--Auto
changeover only (Auto)
14
Temperature Display
0--Fahrenheit
temperature
display (Factory Setting)
1--Celsius
temperature
display
15
Compressor
5--Five-minute
compressor off-time setting (Factory
Setting)
May not appear.
Protection--
See Note f
Minimum-Off Timer in
0, 1, 2, 3, 4--Other
compressor off-time settings
minutes
Press the Next button to go to the beginning
of the Installer
Setup or press the Done button to exit the
Installer Setup and save your settings.
Settings
0--gas,
eit or electric heat with air conditioning (Factory Setting)
1--Heat pump
2--Heat only (two-wire systems or power to open and power to
close zone valves or normally-open zone valves)
3--Heat only with fan
4--Cool
only
0--Changeover
valve--O/B
terminal energized in cooling
(Factory
Setting)
1--Changeover
valve--O/B
terminal energized in heating
0-- Gas or oil furnace--
equipment controls fan in heating
(Factory
Setting)
1-- Electric furnace--
thermostat controls fan in heating
5--5 cph used for gas or oil furnaces (less than 90% efficient)
(Factory
Setting)
1--1 cph used for steam and gravity
3 --3 cph used for hot water and high efficiency furnaces (90%+)
9--9 cph used for electric furnaces
2, 4, 6, 7, 8, 10, 11, 12--Other
cycle rate settings
3--3 cph recommended for compressors (Factory Setting)
1, 2, 4, 5, 6--Other
cycle rate settings
Installer Setup Notes:
a--Installer
Setup Number 2 does not appear if Installer Setup Number 1 is set to 0, 2, 3 or 4.
b--Installer
Setup Number 3 does not appear if installer Setup Number 1 is set to 1, 2 or 4.
c--Installer
Setup Number 5 does not appear if Installer Setup Number 1 is set to 1 or 4.
d--Installer
Setup Number 9 does not appear if Installer Setup Number 1 is set to 2 or 3.
e--Installer
Setup Number 12 does not appear if Installer Setup Number 1 is set to 2, 3 or 4.
f--
Installer Setup Number 15 does not appear if Installer Setup Number 1 is set to 2 or 3.
69-1712--1