Download Print this page

Lennox 90UGF SERIES User's Information Manual

Advertisement

Quick Links

PRODUCT LITERATURE
¤
1997 Lennox Industries Inc.
'DOODV 7 H[DV
0

6XSHUVHGHV 
'R QRW VWRUH RU XVH JDVROLQH RU RWKHU
IODPPDEOH YDSRUV DQG OLTXLGV LQ WKH
YLFLQLW\ RI WKLV RU DQ\ RWKHU DSSOLDQFH
,QVWDOODWLRQ DQG VHUYLFH PXVW EH SHU
IRUPHG E\ D TXDOLILHG LQVWDOOHU VHUYLFH
DJHQF\ RU WKH JDV VXSSOLHU
£
,I WKH LQIRUPDWLRQ LQ WKLV PDQXDO LV QRW
IROORZHG H[DFWO\ D ILUH RU H[SORVLRQ
PD\ UHVXOW FDXVLQJ SURSHUW\ GDPDJH
SHUVRQDO LQMXU\ RU ORVV RI OLIH
:$51,1*
:+$7 72 '2 ,) <28 60(// *$6
- 'R QRW WU\ WR OLJKW DQ\ DSSOLDQFH
- ([WLQJXLVK DQ\ RSHQ IODPHV
- 'R QRW WRXFK DQ\ HOHFWULFDO VZLWFK GR QRW
XVH DQ\ SKRQH LQ \RXU EXLOGLQJ
- ,PPHGLDWHO\ FDOO \RXU JDV VXSSOLHU IURP D
QHLJKERU V SKRQH )ROORZ WKH JDV VXSSOLHU V
LQVWUXFWLRQV
- ,I \RX FDQQRW UHDFK \RXU JDV VXSSOLHU FDOO
WKH ILUH GHSDUWPHQW
8*)
6(5,(6
*$6 )851$&(
/LWKR 86$

Advertisement

loading

Summary of Contents for Lennox 90UGF SERIES

  • Page 1 £ PRODUCT LITERATURE ¤ 1997 Lennox Industries Inc. 'DOODV 7 H[DV 8*) 0  6XSHUVHGHV  6(5,(6 *$6 )851$&( /LWKR 86$ :$51,1* ,I WKH LQIRUPDWLRQ LQ WKLV PDQXDO LV QRW IROORZHG H[DFWO\ D ILUH RU H[SORVLRQ PD\ UHVXOW FDXVLQJ SURSHUW\ GDPDJH SHUVRQDO LQMXU\ RU ORVV RI OLIH :+$7 72 '2 ,) <28 60(// *$6...
  • Page 2 8*) 3$576 ,'(17,),&$7,21 HEAT EXCHANGER FRESH AIR INTAKE ASSEMBLY CONNECTION TOP CAP FLUE COLLAR BURNERS FLAME SIGHT GLASS CABINET COMBUSTION AIR PROVING (PRESSURE) SWITCH BURNER UPPER ACCESS PANEL MANIFOLD COMBUSTION AIR BLOWER VALVE DOOR INTERLOCK SWITCH CONDENSATE TRAP SURELIGHT INTEGRATED CONTROL BLOWER MOTOR...
  • Page 3 Any additions, changes, or conversions required installed and maintained. However, the unit’s perfor- in order for the appliance to satisfactorily meet the application needs must be made by a Lennox mance can be greatly impacted by the individual service technician using factory specified and ap- installation and the operating environment.
  • Page 4 . Do not strongly recommends annual inspection and mainte- force. See figure 3. nance of this appliance. Contact your independent Lennox dealer for an inspection by a qualified service HONEYWELL VR8204 SERIES GAS VALVE technician. /,*+7,1* ,1)250$7,21 $1' 23(5$7,21 :$51,1*...
  • Page 5 Lennox dealer, prior to reinstallation. Filters used inside the 90UGF series unit are available 5 - - Position filter door on end of filter so that the from Lennox and must be ordered separately. These thumb tab side of the filter door is away from the foam filters may be cleaned for reuse.
  • Page 6: Burner Flame

    (on the unit and in the Fresh air grilles and louvers Contact your Lennox dealer for a periodic unit inspec- room where the furnace is installed) - - Must be open tion by a qualified service technician. and unobstructed to provide combustion air.