Adjusting Defrost System - Whirlpool W2H3 Installation Instructions Manual

Table of Contents

Advertisement

Pressure Switch Circuit
The defrost control incorporates a pressure switch circuit that
allows the application of an optional high pressure switch. See
"Defrost Control Board" in "Adjusting Defrost System." During a
demand cycle, the defrost control will lock out the heat pump if
the optional high pressure switch opens. The diagnostic LEDs will
display a pattern for an open high pressure switch. See
"Diagnostic LEDs" in "Troubleshooting the Defrost System."
Defrost Control Board
Optional high pressure switch safety circuit connections
NOTE: To add the pressure switch, remove the factory-installed
jumper.
P1
30
A
60
90
TEST
B
P5
C
D
O-OUT
LO-PS
E
DF
F
Y1-OUT
K3 Relay
HI-PS
G
A. Defrost interval timing pins
B. Test pins
C. Compressor delay pins
D. Reversing valve
E. Low pressure switch

Adjusting Defrost System

FAN
C2
K1 Relay
DS1
H
DS2
U2
K2 Relay
U1
P2
W1
L
C
24V
I
L
R
C5
O
Y1
P6
TST PS DF C
R O Y1
F. Defrost thermostat
G. High pressure switch (optional)
H. Diagnostic LEDs
I. 24V terminal strip connections
The heat pump will remain locked out until the switch resets or is
reset.
Remove the factory-installed jumper before connecting the
optional high pressure switch to the control board.
NOTE: If not using a pressure switch, the factory-installed jumper
wire must be connected.
Adjust Time Between Defrost Cycles
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove the control box cover.
3. Adjust the time period between defrost cycles by placing the
defrost time plug in the proper position. See "Defrost Control
Board."
For 30-minute intervals between defrost cycles, move the
Defrost Time Setting Plug to the pins corresponding
to 30.
For 60-minute intervals between defrost cycles, move the
Defrost Time Setting Plug to the pins corresponding to
60 (this setting is the factory preset setting).
For 90-minute intervals between defrost cycles, move the
Defrost Time Setting Plug to the pins corresponding
to 90.
4. Replace the control box cover.
5. Reconnect power.