Counter-depth freestanding french door bottom-mount refrigerator/freezer (10 pages)
Summary of Contents for Viking VCFB530
Page 1
Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com ll Refrigerator/Freezer F20604A EN (070709J)
Table of Contents IMPORTANT– Please Read and Follow! Warnings & Important Information _________________________________________________________ 3 • Make sure that incoming voltage is the same Your safety and the safety of others is Professional & Professional Integrated as unit rating. An electric rating plate very important.
Page 3
• make sure that you have these materials (not provided with your unit), which are necessary • Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which for proper installation: are not installed properly or do not meet the requirements below.
Dimensions Specifications 30” Professional 30” Professional Description VCFB530 VCRB530 Overall width 30” (76.2 cm) Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. To front edge of side trim: 22-3/16” (56.4 cm) Overall depth from rear 3 –...
Page 5
Dimensions Specifications 30” Professional Integrated 30” Professional Integrated Description VIFB530 VIRB530 Overall width 30” (76.2 cm) Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm) 3 –...
Cutout Dimensions Anti-Tip Dimensions 30” Professional & Professional Integrated 30” Professional & Professional Integrated Electric Outlet Location Professional Anti-Tip Location 6 ” (1 5 .2 c m ) Two 2”x 4” mounting boards 9 ” 3” (7.6 cm) x 3-1/2” (8.9 cm) (2 2 .9 c m ) 9 ”...
Cutout Dimensions Anti-Tip Dimensions 36” Professional & Professional Integrated 36” Professional & Professional Integrated Electric Outlet Location Professional Anti-Tip Location 6 ” (1 5 .2 c m ) Two 2”x 4” mounting boards 9 ” 3” (7.6 cm) x 3-1/2” (8.9 cm) (2 2 .9 c m ) 9 ”...
Page 8
Dimensions Dimensions Dual 30” Professional Dual 30” & 36” Professional 3 – 1 9 / 3 2 ” (9 .1 c m 3 – 1 9 / 3 2 ” (9 .1 c m 4 ” 4 ” – 3 / –...
Page 9
Dimensions Specifications Dual Professional* Dual 36” Professional Description (2) 30” Units (1) 36” & (1) 30” Unit (2) 36” Units Overall width 60” (152.4 cm) 66” (167.6 cm) 72” (182.9 cm) Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16”...
Page 10
Dimensions Dimensions Dual 30” Professional Integrated Dual 30” & 36” Professional Integrated 3 – 1 9 / 3 2 ” 3 – 1 9 / (9 .1 c m 3 2 ” (9 .1 c m 4 ” 4 ” –...
Page 11
Dimensions Specifications Dual Professional Integrated* Dual 36” Professional Integrated Description (2) 30” Units (1) 36” & (1) 30” Unit (2) 36” Units Overall width 60” (152.4 cm) 66” (167.6 cm) 72” (182.9 cm) Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8”...
Cutout Dimensions Anti-Tip Dimensions Dual 30” Professional & Professional Integrated Dual 30” Professional & Professional Integrated Electric Outlet Location Professional Anti-Tip Location 6 ” (1 5 .2 c m ) Two 2”x 4” mounting boards per unit 9 ” 3” (7.6 cm) x 3–1/2” (8.9 cm) 9 ”...
Cutout Dimensions Anti-Tip Dimensions Dual 30” & 36” Professional & Professional Integrated Dual 30” & 36” Professional & Professional Integrated Electric Outlet Location Professional Anti-Tip Location 6 ” (1 5 .2 c m ) 9 ” 9 ” Two 2”x 4” mounting boards per unit (2 2 .9 (2 2 .9 c m )
Cutout Dimensions Anti-Tip Dimensions Dual 36” Professional & Professional Integrated Dual 36” Professional & Professional Integrated Electric Outlet Location Professional Anti-Tip Location 6 ” (1 5 .2 c m ) Two 2”x 4” mounting boards per unit 3” (7.6 cm) x 3–1/2” (8.9 cm) 9 ”...
Cabinet Information Cabinet Information (Professional) (Professional) Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-1/2” (6.4 cm) from the cabinet face. The handle protrudes an additional face protrudes 2-1/2”...
Page 16
Cabinet Information Cabinet Information (Professional Integrated) (Professional Integrated) Professional Integrated models fit flush in standard 24” (61.0 cm) deep cabinet openings with Professional Integrated models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except the handle protrudes 2-1/2” (6.4 cm) into the room. no protrusion into the room except the handle protrudes 2-1/2”...
Cabinet Information Cabinet Information (Designer) (Designer) Designer models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the Designer models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except 2-1/2”...
(1.9 L) of water through the copper tubing walls that can obstruct unit installation. a qualified electrician if you are not sure the • The installation of Viking units with a and into a bucket to remove any particles • Cutout dimensions are accurate.
Installation General Information • Most of the unit’s weight is at the top. TIP OVER HAZARD Extra care is needed when moving the unit Appliance is top heavy and tips easily when to prevent tipping. not completely installed. Keep doors closed •...
Hinge Adjustment Front of unit Remove 4 side screws and remove unit top. Plug in power cord to verify operation. Place unit within 3” of being flush with cabinets. Loosen the 4 hinge screws. Adjust door. Note: Make sure power switch and showroom switch Note: To avoid cabinet damage, place cardboard Retighten 4 hinge screws.
Door Stop Adjustment 90˚ 110˚ 120˚ Open refrigerator door so door stop and shoulder Remove shoulder screw and place in 90˚ or Turn on water supply and check for leaks. Lift unit off rollers to desired height and level unit using screw are accessible.
Performance Checklist Open door. Display should flash. Press “ACTIVATE CONTROLS” button pad and close door. Note: There is a 6 minute delay before the unit starts. h Align/square door(s). h Verify cabinet size. h Verify drain pan is properly installed and h Verify electrical supply and water supply there are no leaks in water connection.
Verify Operations Service & Registration Control Panels Only authorized replacement parts may be used in performing service on the appliance. All Refrigerator Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician.