Download Print this page

CONCORD CXA 40 - 120 User Manual page 2

Advertisement

CAUTION.
To avoid the possibility of injury during the use or cleaning of this
appliance care should be taken when handling edges of sheet steel components.
ALL MODELS
THE GAS SAFETY (INSTALLATION & USE)
REGULATIONS 1994, AMENDMENTS 1996 OR
RULES IN FORCE
obligations on gas users. This appliance must
be installed by a CORGI registered installer.
1. It is ESSENTIAL that the instructions in this booklet
are strictly followed, for safe, economical operation of
the boiler.
2. Do not obstruct ventilation ducts, grilles or openings in
the boiler room, or the passage of combustion and
ventilation air to the boiler.
3. Do not store objects around or on the boiler, and keep
access clear at all times.
4. Switch off and disconnect the electricity supply before
carrying out maintenance work.
5. Do not turn off the boiler if it is to be left unattended in
frosty weather.
CONCORD CXA 40 - 80 models
6
7
LEGEND
1.
Thermostat knob.
2.
Mains gas inlet cock.
3.
Overheat thermostat
button.
4.
Lockout light.
5.
Lockout reset button.
6.
Burner on light.
7.
Overheat light
2
impose certain statutory
Knob setting
1
2
3
4
5
6
5
4
2
WARNING.
This appliance MUST be efficiently earthed.
MAINTENANCE
The appliance should be serviced at least once a
year by a CORGI registered installer.
CLEANING
For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains use a damp
cloth and mild detergent.
DO NOT use abrasive cleaning materials.
o
Approx. flow temp
C
60
64
69
73
77
82
1
o
Approx. flow temp
F
140
147
156
163
171
180
2
Concord CXA 40-120 -
3
User's Guide

Advertisement

loading