Specifications - Fujitsu AG*G09LVCA Technical Manual

Floor type
Hide thumbs Also See for AG*G09LVCA:
Table of Contents

Advertisement

1.

SPECIFICATIONS

Type
Model name
Power source
Available voltage range
Starting current
Airflow rate
Fan
Type × Q'ty
Motor output
Sound pressure level
Sound power level
Heat exchanger type
Type × Q'ty
Compressor
Motor output
Type (Global Warming Potential)
Refrigerant
Charge
Refrigerant oil
Enclosure
Net
Dimensions
(H × W × D)
Gross
Net
Weight
Gross
Size
Method
Connenction
pipe
Pre-charge length
Max. length
Max. height difference
Operation range
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB/19 °CWB. and outdoor temperature of 35°CDB/24°CWB.
Heating : Indoor temperature of 20°CDB/15°CWB. and outdoor temperature of 7°CDB/6°CWB.
Pipe length : 5 m, Height difference : 0 m. (Outdoor unit - Indoor unit)
The protective function may work when using it outside the operation range.
A
Cooling
3
m
/h
Heating
W
Cooling
dB (A)
Heating
Cooling
dB (A)
Heating
Dimensions
(H × W × D)
mm
Fin pitch
Rows × Stages
Pipe type
Fin Type
W
g
Type
Material
Colour
mm
kg
Liquid
mm
Gas
m
Cooling
°C
Heating
- (02 - 01) -
INVERTER HEAT PUMP
AOG09LVCA
AOG12LVCA
230V~ 50Hz
198 - 264V~ 50Hz
3.8
5.5
1,680
1,490
1,680
Propeller fan × 1
Propeller fan × 1
33
47
48
48
49
64
64
65
65
504 × 850 × 36.4
1.40
2 × 24
Copper
Aluminium
Rotary × 1
750
R410A (1975)
1,050
ESTER OIL
Steel
Beige
540 × 790 × 290
648 × 910 × 380
36
40
Ø6.35 (Ø1/4 in.)
Ø9.52 (Ø3/8 in.)
Flare
15
20
15
-10 to 43
-15 to 24
AOG14LVLA
6.4
1,910
1,750
Propeller fan × 1
40
50
50
65
66
546 × 876 × 36.4
1.30
2 × 26
1,100
1,150
578 × 790 × 300
660 × 935× 400
40
44
Ø12.70 (Ø1/2 in.)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ag*g12lvcaAo*g14lvlaAg*g14lvcaAo*g09lvcaAo*g12lvca