CEL DX-1S Installation Manual

Digital pabx (digital switching system )
Table of Contents

Advertisement

Quick Links

DX-1S DIGITAL PABX
Installation Manual
Version 6 - Draft 01
Revised
on
18 August, 1999
CONNECTION ELECTRONICS LTD.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DX-1S and is the answer not in the manual?

Questions and answers

Summary of Contents for CEL DX-1S

  • Page 1 DX-1S DIGITAL PABX Installation Manual Version 6 - Draft 01 Revised 18 August, 1999 CONNECTION ELECTRONICS LTD.
  • Page 2 DX-1S DIGITAL PABX - Installation Manual NOTICE The information contained in this document is believed to accurate in all respects but is not warranted by Connection Electronics Limited. The information is subject to change without notice and should not be construed in any way as a commitment by Connection Electronics Limited or its affiliates and subsidiaries assume no responsibility for any errors or omissions in this document.
  • Page 3: Table Of Contents

    DX-1S DIGITAL PABX - Installation Manual TABLE OF CONTENTS 1.INTRODUCTION............................1 2.INSTALLATION SITE REQUIREMENTS....................1 2.1ENVIRONMENT REQUIREMENTS......................1 2.2SPACE REQUIREMENTS........................1 2.3LOCATION REQUIREMENTS.........................2 2.4AC POWER REQUIREMENTS FOR AC/DC POWER SUPPLY.............2 2.5GROUNDING REQUIREMENTS......................2 2.6REQUIREMENTS OF AC POWER FOR MFC-1S CONSOLE..............3 3.CABLING..............................1 3.1GENERAL PRECAUTIONS........................1 3.2MAXIMUM LENGTH OF EXTENSION CABLE & DOOR PHONE CABLE..........1 3.3MAXIMUM LENGTH OF CONSOLE CABLE...................1...
  • Page 4 FIGURE 4-4.4 CAD600A POWER SUPPLY FRONT PANEL..............14 FIGURE 4-4.5 MFC-1S PC INTERFACE CARD..................17 FIGURE 4-4.6 DX-1S POWER FAILURE TRANSFER MODULE CIRCUIT DIAGRAM......20 FIGURE 5-5.1 HARDWARE PLACEMENT SUGGESTION (WITH SPS-4820 POWER SUPPLY).... 2 FIGURE 5-5.2 HARDWARE PLACEMENT SUGGESTION (WITH SPS-4820A POWER SUPPLY)..3 FIGURE 5-5.3 MODULE SYSTEM CABINET &...
  • Page 5 TABLE 3-2 MAXIMUM LENGTH OF CONSOLE CABLE................1 TABLE 4-1 SYSTEM HARDWARE ASSEMBLY CODE................1 TABLE 4-2 HARDWARE CONFIGURATION....................1 TABLE 4-3 DX-1S MODULE MOTHER BOARD ASSEMBLY..............2 TABLE 4-4 MODULE MOTHER BOARD DIP SWITCH SETTING..............2 TABLE 4-5 DX-1S CABINET ASSEMBLY....................3 TABLE 4-6 DX-1S MODULE SYSTEM CABINET ASSEMBLY..............4 TABLE 4-7 MODULE SYSTEM CABINET CARD SLOTS................4...
  • Page 6 TABLE 4-25 MFC-1S PC INTERFACE CARD ASSEMBLY..............17 TABLE 4-26 MFC-1S CONSOLE ASSEMBLY..................18 TABLE 4-27 DX-1S DISA VOICE CARD ASSEMBLY................19 TABLE 4-28 DX-1S POWER FAILURE TRANSFER MODULE ASSEMBLY...........19 TABLE 5-1 SPS-4820 POWER OUTPUT TERMINAL.................4 TABLE 5-2 MODULE SYSTEM CABINET POWER INPUT TERMINAL............ 4 TABLE 5-3 MODULE SYSTEM CABINET REAR PANEL CONNECTORS..........7...
  • Page 7 DX-1S DIGITAL PABX - Installation Manual TABLE 5-20 LINE CONNECTOR L15 PIN ASSIGNMENT............... 25 TABLE 5-21 POWER FAILURE TRANSFER MODULE PANEL CONNECTORS........26 TABLE 5-22 PFT LINE CONNECTOR PIN ASSIGNMENT...............29 TABLE 5-23 LINE CONNECTOR PIN ASSIGNMENT OF CALLER ID CARD.........33 TABLE 5-24 PC STATION REQUIREMENTS FOR MFC-1S CONSOLE..........34 TABLE 5-25 MFC-1S CONSOLE CONNECTORS..................35...
  • Page 9: Introduction

    DX-1S DIGITAL PABX - Installation Manual 1.INTRODUCTION This manual provides general installation procedures for DX-1S Digital PABX System. It is suggested that the technical persons should read these information thoroughly before beginning the installation. Also refer to Programming Manual for information about customizing the system for a particular site.
  • Page 11: Installation Site Requirements

    Table 2-1 ENVIRONMENT REQUIREMENTS 2.2SPACE REQUIREMENTS The minimum space between the surrounding surface and left panel, right panel and top panel of DX-1S System Cabinet should be greater than 100mm. The minimum space between the rear wall and the back panel should be greater than 250mm.
  • Page 12: Location Requirements

    DX-1S DIGITAL PABX - Installation Manual Figure 2-2.2 FRONT AND REAR PANEL CLEARANCE REQUIREMENT 2.3LOCATION REQUIREMENTS There are some guide lines for location selection :  Dry, clean and good ventilated.  Easy accessible  Not extreme heat or cold ...
  • Page 13: Requirements Of Ac Power For Mfc-1S Console

    DX-1S DIGITAL PABX - Installation Manual 2.6REQUIREMENTS OF AC POWER FOR MFC-1S CONSOLE The MFC-1S Console requires a single phase 220V 50Hz AC main power. The AC power should meet the following requirements :  The power socket is dedicated for system use and should not share with other equipment.
  • Page 15: General Precautions

    DX-1S DIGITAL PABX - Installation Manual 3.CABLING 3.1GENERAL PRECAUTIONS  Use Module Distribution Frame (MDF) to concentrate all incoming and outgoing cables.  Must install Gas Arrestor or Surge Protector for all the trunk lines to protect the system from surge damage.
  • Page 17: Hardware Overview

    Marking 500-09004-1 DX-1S Module Mother Board 500-09005-1 DX-1S Module Control Card 500-09006-1 DX-1S Power Supply Card 500-09012-1 DX-1S TRK/EXT Card (4 Trk + 12 Ext) 500-09013-1 DX-1S EXT Card (16 Ext) 500-09015-1 DX-1S Module Accessories 500-09020-1 DX-1S Cabinet 500-09021-1 DX-1S DISA Voice Card...
  • Page 18: Dx-1S Module Mother Board

    DX-1S DIGITAL PABX - Installation Manual 4.3DX-1S MODULE MOTHER BOARD 4.3.1HARDWARE ASSEMBLY DX-1S Module Mother Board includes the following hardware : Assembly Included DX-1S Module Mother Board Table 4-3 DX-1S MODULE MOTHER BOARD ASSEMBLY 4.3.2DESCRIPTION Module Mother Board is installed in the Cabinet. There are 17 slots connectors in the soldering side of the printed circuit board.
  • Page 19: Dx-1S Cabinet

    DX-1S DIGITAL PABX - Installation Manual 4.5DX-1S CABINET 4.5.1HARDWARE ASSEMBLY DX-1S Cabinet includes the following hardware : Assembly Included DX-1S Cabinet Hex Key Table 4-5 DX-1S CABINET ASSEMBLY 4.5.2DESCRIPTION The Cabinet includes a 19 inches (483mm) width metal cabinet. All the cards and boards should install inside the cabinet.
  • Page 20: Dx-1S Module System Cabinet

    DX-1S DIGITAL PABX - Installation Manual 4.6DX-1S MODULE SYSTEM CABINET 4.6.1HARDWARE ASSEMBLY DX-1S Module System Cabinet includes the following hardware : Assembly Included DX-1S Module Mother Board DX-1S Module Accessories DX-1S Cabinet Hex Key Table 4-6 DX-1S MODULE SYSTEM CABINET ASSEMBLY 4.6.2DESCRIPTION...
  • Page 21: Dx-1S Module Control Card (Mcc)

    DX-1S DIGITAL PABX - Installation Manual 4.7DX-1S MODULE CONTROL CARD (MCC) 4.7.1HARDWARE ASSEMBLY DX-1S Module Control Card includes the following hardware : Assembly Included DX-1S Module Control Card Table 4-8 DX-1S MODULE CONTROL CARD ASSEMBLY 4.7.2DESCRIPTION The Module Control Card is labeled as MCC in the card ejectors and is installed in the first slot of Module System Cabinet.
  • Page 22: Dx-1S Power Supply Card (Psc)

    DX-1S DIGITAL PABX - Installation Manual 4.8DX-1S POWER SUPPLY CARD (PSC) 4.8.1HARDWARE ASSEMBLY DX-1S Power Supply Card includes the following hardware : Assembly Included DX-1S Power Supply Card Table 4-10 DX-1S POWER SUPPLY CARD ASSEMBLY 4.8.2DESCRIPTION The Module Power Supply Card is installed in the last slot (17th slot) of Module System Cabinet and is labeled as PSC in the card ejectors.
  • Page 23: Dx-1S Trk/Ext Card - 4 Trk + 12 Ext (T/E)

    DX-1S DIGITAL PABX - Installation Manual 4.9DX-1S TRK/EXT CARD - 4 TRK + 12 EXT (T/E) 4.9.1HARDWARE ASSEMBLY DX-1S TRK/EXT Card includes the following hardware : Assembly Included DX-1S TRK/EXT Card Table 4-12 DX-1S TRK/EXT CARD ASSEMBLY 4.9.2DESCRIPTION TRK/EXT Card is one of the peripheral cards and is labeled as T/E in the card ejectors. It can be installed in second to sixteenth line card slots.
  • Page 24: Dx-1S Ext Card - 16 Ext (Ext)

    DX-1S DIGITAL PABX - Installation Manual 4.10DX-1S EXT CARD - 16 EXT (EXT) 4.10.1HARDWARE ASSEMBLY DX-1S EXT Card includes the following hardware : Assembly Included DX-1S EXT Card Table 4-15 DX-1S EXT CARD ASSEMBLY 4.10.2DESCRIPTION EXT Card is one of the peripheral cards and is labeled as EXT in the card ejectors. It can be installed in any line card slots (2nd ~ 16th slots).
  • Page 25: Dx-1S Caller Id Card (Cic)

    DX-1S DIGITAL PABX - Installation Manual 4.11DX-1S CALLER ID CARD (CIC) 4.11.1HARDWARE ASSEMBLY DX-1S Caller ID Card includes the following hardware : Assembly Included DX-1S Caller ID Card Table 4-17 DX-1S CALLER ID CARD ASSEMBLY 4.11.2DESCRIPTION Caller ID Card is one of the peripheral cards and is labeled as CIC in the card ejectors. It can be installed in any line card slots (2nd ~ 16th slots).
  • Page 26: Sps-4820 Battery Backup Power Supply

    DX-1S DIGITAL PABX - Installation Manual 4.12SPS-4820 BATTERY BACKUP POWER SUPPLY 4.12.1HARDWARE ASSEMBLY For SPS-4820 Battery Backup Power Supply includes the following hardware : Assembly Included SPS-4820 Power Supply Power Cord with Built-in Surge Protection Module Table 4-19 SPS-4820 BATTERY BACKUP POWER SUPPLY ASSEMBLY 4.12.2DESCRIPTION...
  • Page 27: Figure 4-4.3 Sps-4820 Power Supply Front Panel

    DX-1S DIGITAL PABX - Installation Manual Figure 4-4.3 SPS-4820 POWER SUPPLY FRONT PANEL 4.12.4INPUT VOLTAGE PROTECTION If the AC input voltage is lower than 170V or higher than 255V when switching on, the Power Supply will shut down the output, the I/P Alarm Red LED will light up and the internal buzzer will output alarm signal to indicate the alarm condition.
  • Page 28 DX-1S DIGITAL PABX - Installation Manual 4.12.7EQUALIZATION CHARGE MODE Since the backup batteries is always in standby condition but seldom discharge, the batteries will become inactive and the capacity gradually decrease. The Equalization Charge activates the chemical and electrochemical of the batteries and recover the capacity. The Equalization Charge is to increase the charging voltage by 2.5V (56V charging voltage) to charge up the batteries.
  • Page 29: Table 4-20 Sps-4820 Power Supply Specification

    DX-1S DIGITAL PABX - Installation Manual 4.12.10SPECIFICATION Parameter Minimum Value Typical Value Maximum Value AC Input Voltage 170V AC 220V AC 285V AC AC Input Frequency 47Hz 63Hz Max. Input Current Input Undervoltage 170V AC Protection Threshold Input Overvoltage 265V AC...
  • Page 30: Cad600A Battery Backup Power Supply

    DX-1S DIGITAL PABX - Installation Manual 4.13CAD600A BATTERY BACKUP POWER SUPPLY 4.13.1HARDWARE ASSEMBLY For CAD600A Battery Backup Power Supply includes the following hardware : Assembly Included CAD600A Power Supply Power Cord Table 4-22 CAD600A BATTERY BACKUP POWER SUPPLY ASSEMBLY 4.13.2DESCRIPTION CAD600A Battery Backup Power Supply is a separate device.
  • Page 31 DX-1S DIGITAL PABX - Installation Manual 4.13.5OUTPUT OVER-VOLTAGE PROTECTION The power supply includes output over-voltage protection. If the output voltage is higher than 58 voltage, the output will stay in the “Hiccup” mode. The “HIGH VOLTS ALARM” red LED flashes more rapidly as the loading increases.
  • Page 32: Table 4-23 Cad600A Power Supply Specification

    DX-1S DIGITAL PABX - Installation Manual 4.13.9SPECIFICATION Parameter Minimum Value Typical Value Maximum Value AC Input Voltage 160V AC 220V AC 270V AC AC Input Frequency 47Hz 440Hz Max. Input Current Input Overvoltage 270V AC Protection Threshold Output Voltage 53V DC 53.5V DC...
  • Page 33: Mfc-1S Pc Interface Card With Console Software

    MFC-1S Console. The console system will transmit or receive the system data through the PC Interface Card to communicate with DX-1S System. Since the communication ports in the card are optical isolated, they prevent the surge which induces in the console bus to damage the system.
  • Page 34: Mfc-1S Console

    DX-1S DIGITAL PABX - Installation Manual 4.15MFC-1S CONSOLE 4.15.1HARDWARE ASSEMBLY MFC-1S PC Console is a dedicated operator console for DX-1S System. The Console includes the following hardware : MFC-1S Console include PC Computer Station with MFC-1S PC Interface Card Installed 9”...
  • Page 35: Dx-1S Disa Voice Card

     Trunk No Answer Voice Announcement  Voice Message Recording 4.17DX-1S POWER FAILURE TRANSFER MODULE 4.17.1HARDWARE ASSEMBLY DX-1S Power Failure Transfer Module includes the following hardware : Assembly Include DX-1S Power Failure Transfer Card DX-1S Power Failure Transfer Module Panel Table 4-28 DX-1S POWER FAILURE TRANSFER MODULE ASSEMBLY 4.17.2DESCRIPTION...
  • Page 36: Figure 4-4.6 Dx-1S Power Failure Transfer Module Circuit Diagram

    DX-1S DIGITAL PABX - Installation Manual Figure 4-4.6 DX-1S POWER FAILURE TRANSFER MODULE CIRCUIT DIAGRAM...
  • Page 37: Hardware Installation

    DX-1S DIGITAL PABX - Installation Manual 5.HARDWARE INSTALLATION 5.1BASIC PRECAUTIONS FOR INSTALLATION  Before installing or replacing the cards, the ground connection of Module System Cabinet must be well connected.  When installing or replacing the cards to Module System Cabinet, ensure the power has switched off.
  • Page 38: Figure 5-5.1 Hardware Placement Suggestion (With Sps-4820 Power Supply)

    DX-1S DIGITAL PABX - Installation Manual Figure 5-5.1 HARDWARE PLACEMENT SUGGESTION (WITH SPS-4820 POWER SUPPLY)
  • Page 39: System Ground Terminal

    DX-1S DIGITAL PABX - Installation Manual Figure 5-5.2 HARDWARE PLACEMENT SUGGESTION (WITH SPS-4820A POWER SUPPLY) 5.3SYSTEM GROUND TERMINAL The System Ground Terminal can be a brass rod with several cable mounting screw or a large current terminal block with all pin short together. The System Ground Terminal must be very low resistance and able to withstand large current.
  • Page 40: Sps-4820 Power Supply Inspection

    DX-1S DIGITAL PABX - Installation Manual 5.7SPS-4820 POWER SUPPLY INSPECTION  Unpack the SPS-4820 Power Supply.  Visually inspect the Power Supply is free from damage during transportation. 5.8CONNECTION BETWEEN SYSTEM CABINET AND SPS-4820 POWER SUPPLY  Place Module System Cabinet and Power Supply to the assigned position.
  • Page 41: Figure 5-5.3 Module System Cabinet & Power Supply Connection Diagram

    DX-1S DIGITAL PABX - Installation Manual Figure 5-5.3 MODULE SYSTEM CABINET & POWER SUPPLY CONNECTION DIAGRAM...
  • Page 42: Verify Ground Connection

    DX-1S DIGITAL PABX - Installation Manual 5.9VERIFY GROUND CONNECTION  Use a digital multi-meter to measure the AC voltage between the ground pin of the AC power socket (the Ground of Electrical System) and the #6 AWG approved ground wire. The voltage should not be over 1V.
  • Page 43: Connectors In Rear Panel Of Module System Cabinet

    DX-1S DIGITAL PABX - Installation Manual 5.10CONNECTORS IN REAR PANEL OF MODULE SYSTEM CABINET The connectors in the rear panel are for the external cables connection as following : Connector Type Function Power Input 4 Way Terminal Block For -48V Power Supply &...
  • Page 44: Connect Console Cable For Module System Cabinet

    DX-1S DIGITAL PABX - Installation Manual Figure 5-5.5 DX-1S MODULE SYSTEM CABINET REAR PANEL VIEW 5.11CONNECT CONSOLE CABLE FOR MODULE SYSTEM CABINET  Connect the 4-core cable from Console Connectors of Module System Cabinets to MDF. Console Connector Description (DB-9 Male)
  • Page 45: Connect Music/Page/Relay Cable For Module System Cabinet

    DX-1S DIGITAL PABX - Installation Manual Figure 5-5.6 CONSOLE CONNECTOR DIAGRAM 5.12CONNECT MUSIC/PAGE/RELAY CABLE FOR MODULE SYSTEM CABINET  Connect the 6-core cable from Music/Page/Relay Connectors of Module System Cabinets to MDF. M/P/R Connector Description (DB-9 Female) Pin 1 Music Input...
  • Page 46: Connect Line Connector Cables For Module System Cabinet

    DX-1S DIGITAL PABX - Installation Manual 5.13CONNECT LINE CONNECTOR CABLES FOR MODULE SYSTEM CABINET  Connect the 32-core cables from Line Connectors L01-L15 of Module System Cabinet to MDF. Figure 5-5.8 LINE CONNECTOR DIAGRAM...
  • Page 47: Table 5-6 Line Connector L01 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.1LINE CONNECTOR L01 TRK/EXT Card is installed EXT Card is installed Trunk 1 Tip Extension 0 Tip Trunk 1 Ring Extension 0 Ring Trunk 2 Tip Extension 1 Tip Trunk 2 Ring Extension 1 Ring...
  • Page 48: Table 5-7 Line Connector L02 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.2LINE CONNECTOR L02 TRK/EXT Card is installed EXT Card is installed Trunk 5 Tip Extension 16 Tip Trunk 5 Ring Extension 16 Ring Trunk 6 Tip Extension 17 Tip Trunk 6 Ring Extension 17 Ring...
  • Page 49: Table 5-8 Line Connector L03 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.3LINE CONNECTOR L03 TRK/EXT Card is installed EXT Card is installed Trunk 9 Tip Extension 32 Tip Trunk 9 Ring Extension 32 Ring Trunk 10 Tip Extension 33 Tip Trunk 10 Ring Extension 33 Ring...
  • Page 50: Table 5-9 Line Connector L04 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.4LINE CONNECTOR L04 TRK/EXT Card is installed EXT Card is installed Trunk 13 Tip Extension 48 Tip Trunk 13 Ring Extension 48 Ring Trunk 14 Tip Extension 49 Tip Trunk 14 Ring Extension 49 Ring...
  • Page 51: Table 5-10 Line Connector L05 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.5LINE CONNECTOR L05 TRK/EXT Card is installed EXT Card is installed Trunk 17 Tip Extension 64 Tip Trunk 17 Ring Extension 64 Ring Trunk 18 Tip Extension 65 Tip Trunk 18 Ring Extension 65 Ring...
  • Page 52: Table 5-11 Line Connector L06 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.6LINE CONNECTOR L06 TRK/EXT Card is installed EXT Card is installed Trunk 21 Tip Extension 80 Tip Trunk 21 Ring Extension 80 Ring Trunk 22 Tip Extension 81 Tip Trunk 22 Ring Extension 81 Ring...
  • Page 53: Table 5-12 Line Connector L07 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.7LINE CONNECTOR L07 TRK/EXT Card is installed EXT Card is installed Trunk 25 Tip Extension 96 Tip Trunk 25 Ring Extension 96 Ring Trunk 26 Tip Extension 97 Tip Trunk 26 Ring Extension 97 Ring...
  • Page 54: Table 5-13 Line Connector L08 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.8LINE CONNECTOR L08 TRK/EXT Card is installed EXT Card is installed Trunk 29 Tip Extension 112 Tip Trunk 29 Ring Extension 112 Ring Trunk 30 Tip Extension 113 Tip Trunk 30 Ring Extension 113 Ring...
  • Page 55: Table 5-14 Line Connector L09 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.9LINE CONNECTOR L09 TRK/EXT Card is installed EXT Card is installed Trunk 33 Tip Extension 128 Tip Trunk 33 Ring Extension 128 Ring Trunk 34 Tip Extension 129 Tip Trunk 34 Ring Extension 129 Ring...
  • Page 56: Table 5-15 Line Connector L10 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.10LINE CONNECTOR L10 TRK/EXT Card is installed EXT Card is installed Trunk 37 Tip Extension 144 Tip Trunk 37 Ring Extension 144 Ring Trunk 38 Tip Extension 145 Tip Trunk 38 Ring Extension 145 Ring...
  • Page 57: Table 5-16 Line Connector L11 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.11LINE CONNECTOR L11 TRK/EXT Card is installed EXT Card is installed Trunk 41 Tip Extension 160 Tip Trunk 41 Ring Extension 160 Ring Trunk 42 Tip Extension 161 Tip Trunk 42 Ring Extension 161 Ring...
  • Page 58: Table 5-17 Line Connector L12 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.12LINE CONNECTOR L12 TRK/EXT Card is installed EXT Card is installed Trunk 45 Tip Extension 176 Tip Trunk 45 Ring Extension 176 Ring Trunk 46 Tip Extension 177 Tip Trunk 46 Ring Extension 177 Ring...
  • Page 59: Table 5-18 Line Connector L13 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.13LINE CONNECTOR L13 TRK/EXT Card is installed EXT Card is installed Trunk 49 Tip Extension 192 Tip Trunk 49 Ring Extension 192 Ring Trunk 50 Tip Extension 193 Tip Trunk 50 Ring Extension 193 Ring...
  • Page 60: Table 5-19 Line Connector L14 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.14LINE CONNECTOR L14 TRK/EXT Card is installed EXT Card is installed Trunk 53 Tip Extension 208 Tip Trunk 53 Ring Extension 208 Ring Trunk 54 Tip Extension 209 Tip Trunk 54 Ring Extension 209 Ring...
  • Page 61: Table 5-20 Line Connector L15 Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.13.15LINE CONNECTOR L15 TRK/EXT Card is installed EXT Card is installed Trunk 57 Tip Extension 224 Tip Trunk 57 Ring Extension 224 Ring Trunk 58 Tip Extension 225 Tip Trunk 58 Ring Extension 225 Ring...
  • Page 62: Install Power Failure Transfer Module

    The module includes three 36 Way Centronic Socket Connectors, one 4 Way Terminal Block and a Power Switch and Power LED on the panel : Figure 5-5.9 DX-1S POWER FAILURE TRANSFER MODULE PANEL The connectors in the rear panel are for the external cables connection as following :...
  • Page 63: Figure 5-5.10 Power Failure Transfer Module Installation

    DX-1S DIGITAL PABX - Installation Manual 5.14.2INSTALL POWER FAILURE TRANSFER MODULE IN MODULE SYSTEM CABINET  Unpack the packing of the module.  There is no jumper or Dip Switch setting in module.  Remove the Lower Rear Panel.  Install the Power Failure Transfer Module in the position of Lower Rear Panel.
  • Page 64: Figure 5-5.11 Pft Line Connector Diagram

    DX-1S DIGITAL PABX - Installation Manual 5.14.4CONNECT PFT LINE CONNECTOR CABLES FOR POWER FAILURE TRANSFER MODULE  Connect the 32-core cables from PFT 1~4 Connector of Power Failure Transfer Module to MDF.  Connect the 32-core cables from PFT 5~8 Connector of Power Failure Transfer Module to MDF.
  • Page 65: Table 5-22 Pft Line Connector Pin Assignment

    DX-1S DIGITAL PABX - Installation Manual 5.14.5PFT LINE CONNECTOR PIN ASSIGNMENT PFT 1~4 Pinout PFT 5~8 Pinout PFT 9~12 Pinout 1st Trunk Line Tip 5th Trunk Line Tip 9th Trunk Line Tip 1st Trunk Line Ring 5th Trunk Line Ring...
  • Page 66: Install Power Supply Card

    DX-1S DIGITAL PABX - Installation Manual 5.15INSTALL POWER SUPPLY CARD  Unpack the packing of the card.  Check the fuse condition and value. F1 is a 1.5A quick acting fuse. F2 is a 2A quick acting fuse and F3 is a 0.5A quick acting fuse.
  • Page 67: Figure 5-5.12 Disa Voice Card Installation

    DX-1S DIGITAL PABX - Installation Manual Figure 5-5.12 DISA VOICE CARD INSTALLATION...
  • Page 68: Install Trk/Ext Card And Ext Card

    DX-1S DIGITAL PABX - Installation Manual 5.18INSTALL TRK/EXT CARD AND EXT CARD  Unpack the packing of the cards.  There is no jumper or Dip Switch setting in TRK/EXT Card and EXT Card.  Install the first TRK/EXT Card to the 2nd slot of the Module System Cabinet which is label as L01.
  • Page 69: Table 5-23 Line Connector Pin Assignment Of Caller Id Card

    DX-1S DIGITAL PABX - Installation Manual EXT Card is installed CIC channel 1 Tip CIC channel 1 Ring Not Used Not Used CIC channel 2 Tip CIC channel 2 Ring Not Used Not Used CIC channel 3 Tip CIC channel 3 Ring...
  • Page 70: Install Mfc-1S Pc Interface Card

    DX-1S DIGITAL PABX - Installation Manual 5.20INSTALL MFC-1S PC INTERFACE CARD 5.20.1INSTALL THE MFC-1S PC INTERFACE CARD IN PC STATION  Unpack the packing of the card.  Inspect all the items are free from damage.  Check correct number of items received.
  • Page 71: Install Mfc-1S Console

    5.21.1CONNECTORS IN MFC-1S There is a power switch in the front panel of PC Computer Station. The rear panel of PC Computer Station includes the connectors for monitor, keyboard, printer and DX-1S System connection. Console-In Connector is for connection with DX-1S System or prior MFC-1S Console. Console-Out Connector is for next MFC-1S Console connection.
  • Page 72: Figure 5-5.14 Rear Panel Of Mfc-1S Console (Version A)

    DX-1S DIGITAL PABX - Installation Manual The rear panel diagrams of Version A and Version B are as following : Figure 5-5.14 REAR PANEL OF MFC-1S CONSOLE (VERSION A) Figure 5-5.15 REAR PANEL OF MFC-1S CONSOLE (VERSION B)
  • Page 73: Figure 5-5.16 Console-In And Console-Out (Mj-66) Connector Diagram

    DX-1S DIGITAL PABX - Installation Manual 5.21.2INSTALL THE FIRST MFC-1S CONSOLE  Unpack the packing of the console.  Inspect all the items are free from damage.  Check correct number of items received : PC Computer Station 9” VGA Monochrome Monitor...
  • Page 74: Table 5-27 Mfc-1S Console To Console Connection

    DX-1S DIGITAL PABX - Installation Manual 5.21.3INSTALL THE SECOND TO SIXTEENTH MFC-1S CONSOLES  Unpack the packing of the console.  Inspect all the items are free from damage.  Check correct number of items received.  Open the cover of PC Computer System cabinet and check if all the cards is well installed in the mother board.
  • Page 75: Figure 5-5.17 Mfc-1S Consoles Connection Diagram

    DX-1S DIGITAL PABX - Installation Manual Figure 5-5.17 MFC-1S CONSOLES CONNECTION DIAGRAM...
  • Page 76: Figure 5-5.18 Console Loop Testing Plug Diagram

    DX-1S DIGITAL PABX - Installation Manual 5.21.4VERIFY THE CONSOLE CABLE LOOP RESISTANCE  The total loop resistance of console cable from Module System Cabinet to the last Console should be less than 40 ohm.  All consoles must be power down.
  • Page 77: Printer Connection

    DX-1S DIGITAL PABX - Installation Manual 5.22PRINTER CONNECTION A parallel printer and a serial printer should be connected to the console if the console need to perform SMDR, programming data or diagnostic result print out. For parallel printer, the printer should be PC Compatible parallel printer and connected to Printer 1 Connector.
  • Page 78: Door Lock Connection Requirement

    DX-1S DIGITAL PABX - Installation Manual 5.25DOOR LOCK CONNECTION REQUIREMENT The maximum switching current and voltage for Door Lock Control should not be over the contact rating as following : Relay Contact Rating Specification Relay Contact Normally Open Relay Time...
  • Page 79: Basic Hardware Test

    DX-1S DIGITAL PABX - Installation Manual 6.BASIC HARDWARE TEST 6.1CHECKING  The Power Supply SPS-4820 is switched OFF.  The Battery Output Circuit Breaker is switched OFF.  The Power Output Circuit Breaker is switched OFF.  All MFC-1S Console is switched OFF.
  • Page 80: Mfc-1S Console Power On Test

     Start MFC-1S Console Setup Programming. (Reference to MFC-1S Console Operation Manual for details.)  Start DX-1S System Programming. (Reference to Programming Manual for details.) 6.4POWER FAILURE TRANSFER MODULE TEST  Switch the Power Switch in Power Failure Transfer Module Panel to ON position.
  • Page 81: Caller Id Card Function Test

    6.7CALLER ID CARD FUNCTION TEST Caller ID Card Detection  When DX-1S start, it will display the cards inserted in L01 ~ L15 on the MFC-1S display. Check if Caller ID Card is correctly detected. Caller ID Card should have the display: “CIC XX XX XX XX XX XX XX XX”. Where XX is the version number of each CIC channel.
  • Page 83: Upgrade System Software

    DX-1S DIGITAL PABX - Installation Manual 7.UPGRADE SYSTEM SOFTWARE 7.1DESCRIPTION The system software will change from time to time to increase the features or improve the performance of the system. In order to upgrade the system software for existing systems, U2, U37 and U79 integrated circuits in Module Control Card may need to be rewritten the content with new data or replaced with new version chips.
  • Page 84: Basic Precautions For Upgrade

    DX-1S DIGITAL PABX - Installation Manual 7.4BASIC PRECAUTIONS FOR UPGRADE  When installing or replacing the Module Control Card to Module System Cabinet, ensure the power has switched off.  Do not touch the board components or connectors without static-discharge precautions.
  • Page 85: Dx-1Su

    The main difference between DX-1S and DX-1SU are system cabinet and power supply. 8.2DX-1SU MODULE SYSTEM CABINET DX-1SU cabinet has the same dimension of the DX-1S cabinet, but the right area inside the cabinet is reserved for the DX-1SU power supply.
  • Page 86: Installation

    Weight 8.4INSTALLATION The installation of DX-1SU should follow the precaution and requirement as in DX-1S installation. Since DX-1SU has a newly design power supply and cabinet, the following section will discuss the connection of DX-1SU with backup battery and power.
  • Page 87: Figure 8-8.1 Dx-1Su System Cabinet, Power & Battery Connection Diagram

    DX-1S DIGITAL PABX - Installation Manual Power Input Terminal Description Pin 1 Battery + Pin 2 Battery - Pin 3 Surge Ground Pin 4 Surge Ground Table 8-2 DX-1SU SYSTEM CABINET POWER OUTPUT TERMINAL Figure 8-8.1 DX-1SU SYSTEM CABINET, POWER & BATTERY CONNECTION DIAGRAM...

Table of Contents