Honeywell Variable Millivolt Valve
If any of the original wire as supplied must be replaced, it
must be replaced with Type AWM 105°C – 18 GA. wire.
Hi/Lo Flame
Adjustment
Knob
Thermopile
*Optional ON/OFF SWITCH
OR WALL SWITCH
OR THERMOSTAT
OR REMOTE CONTROL RECEIVER
Schematic Representation Only
Figure 8

WARRANTY

Your gas appliance is covered by a limited
twenty year warranty. You will find a copy of
the warranty accompanying this manual.
Please read the warranty to be familiar with its
coverage.
Retain this manual. File it with your other
documents for future reference.

PRODUCT REFERENCE INFORMATION

We recommend that you record the following important information about your fireplace. Please
contact your Lennox dealer for any questions or concerns. For the number of your nearest Lennox
dealer, please call 1-800-9-LENNOX
Your Fireplace's Model Number _______________________________________
Your Fireplace's Serial Number ________________________________________
The Date On Which Your Fireplace Was Installed __________________________
The Type of Gas Your Fireplace Uses ___________________________________
Your Dealer's Name _________________________________________________
When ordering repair parts, always give the
following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
8
Blower Wiring Diagram For Optional
FBK-100 AND FBK-200 KITS
If any of the original wire as supplied must be replaced,
it must be replaced with Type AWM 105°C – 18 GA. wire.
Break Tab Off on
Hot side of Outlet Box
Piezo Ignitor
Outlet Box Green
Ground Screw
BLOWER
Gas Control
Knob
Plug Blower Cord
into Bottom
Receptacle
of Outlet Box
Hot Side of
Outlet Box
*Blower speed control switch is provided in
FBK-200 blower kit.
Schematic Representation Only
Figure 9

REPLACEMENT PARTS

A complete parts list is found at the end of this
manual. Use only parts supplied from the
manufacturer.
Normally, all parts should be ordered through
your Lennox dealer. Parts will be shipped at
prevailing prices at time of order.
If you encounter any problems or have any
questions concerning the installation or appli-
cation of this system, please contact your dealer.
For the name of your nearest dealer contact:
LENNOX HEARTH PRODUCTS
1110 West Taft Avenue • Orange, CA
92865
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
White Wire To Opposite
Side of Outlet Box
(Neutral Side)
Black Pigtail
G
W
120
VAC.
BK
Red Pigtail
*Optional Blower
Junction Box
Control Switch
Outlet Box
Blower Wiring Diagram for the Optional
FBK-250 Kits
If any of the original wire as supplied must be replaced,
it must be replaced with Type AWM 105°C – 18 GA. wire.
Outlet Box Green
Ground Screw
Optional FBK-250
Module
OPT
BLOWER
Factory Wired
Schematic Representation Only
Figure 10

ACCESSORY COMPONENTS

INDICATOR
SIGNAL
ON
LIGHT
OFF
ON/OFF
BUTTONS
Remote Control System (Standard)
Standard Remote Control System
(Model RC)
The Model RC (Standard) Remote Control
System, features a simplistic on/off control
function for the fireplace. This model includes
a hand-held transmitter, a remote receiver
with wall-mount coverplate and all hardware
required to install the unit. The remote receiver
can be wall or hearth mounted.
The transmitter has ON and OFF functions that
are activated by pressing either button on the
face of the transmitter. When a button on the
transmitter is pressed, a signal light illuminates
briefly to verify that a signal has been sent.
The Model RC is designed to operate with all
millivolt ignition systems, as well as electronic
ignition systems. It may be installed with use
for either natural or propane gas appliances.
The RC offers ease of installation and allows
you to execute on-off commands to the fire-
place effortlessly with one simple motion.
The Model RC comes complete with detailed
operating instructions.
G
120
BK
VAC.
W
White Wire
To Opposite
Side
Junction Box
Field Wired
26N04