User Manual
Teleste Corporation
DVP432
Power Supply
DVP432 User Manual, 59300088, rev004

Advertisement

Table of Contents
loading

Summary of Contents for Teleste UHC-P

  • Page 1 EASI Accessories User Manual Teleste Corporation DVP432 Power Supply DVP432 User Manual, 59300088, rev004...
  • Page 2: Table Of Contents

    Contents Introduction General ..............................2 Installation Quick Instructions ............................4 Mechanical Installation ..........................5 Connectors..............................5 Indicators..............................6 Using several DVP’s in parallel to implement back-up ................6 Configuring the DVP432 General ..............................7 Establishing a Data Connection........................7 Starting CATVisor Commander.......................8 CATVisor Commander - Connected Window ..................9 Configuring the units using CATVisor Commander................10 DVP432 Configuration Display General ..............................12...
  • Page 3: Introduction

    Introduction General The DVP432 is a power supply for the EASI rack installations. It features enhanced EMC protection, output voltage fine-tuning and stabilisation. Two logically controlled long life fans gives the unit optimal cooling and thus further increased reliability. The DVP432 is using the primary switch mode technology providing a wide input voltage range, high efficiency and reliability.
  • Page 4 The power supply has an electrical screening of class 1 and it is intended for an indoor installation in a dry place. The unit must not be installed in a place where it can be exposed to dripping or splashing water. The operating voltage is 220…240 VAC, 50…60 Hz.
  • Page 5: Installation

    Installation Quick Instructions • The DVP power supply unit is installed on the extreme left- hand side of the DVX002 installation frames (positions 1&2), but it can also be installed to any other frame position, if necessary. When the EASI system consists of several installation frames, each frame must have a bus address specified (refer to the DVX002’s User Manual).
  • Page 6: Mechanical Installation

    Mechanical Installation Place the DVP432 power supply into a DVX002 installation frame equipped with a specified DVX bus address (see frame User Manual). The unit is normally placed into the first frame position on the left-hand side, but it also can be put to any other frame position, if necessary.
  • Page 7: Indicators

    Indicators The “MODULE” -indicator normally shows green, turning to flashing green when software or a programmer addresses the module. If the module have alarm(s), the indicator shows red. The “TEMPERATURE” -indicator should also show green. If the indicator turns to yellow, the unit temperature has already risen above the error flag temperature (see table) and the output power is switched off until the temperature is back to the normal level.
  • Page 8: Configuring The Dvp432

    Configuring the DVP432 General DVP units are fully controllable with the Commander Software. The purpose of this document is to introduce the functions of the Configuration Display of the DVP power supplies. The Configuration Display is a part of the CATVisor Commander software application.
  • Page 9: Starting Catvisor Commander

    Starting CATVisor Commander Launch Commander. When the program has started the following Commander main view will initially appear as seen below. Commander Main View, new connection. Commander is now running, but not yet connected. A connection to the EASI module must now be established or reopened.
  • Page 10: Catvisor Commander - Connected Window

    CATVisor Commander - Connected Window Pull-Down Configuration Tool Bar Menus Display Element Directory Status Bar Event Log Commander Main View, connected window. Commander view is divided into three main sections: Element Directory, Configuration Display and Event Log. The default view has additionally the Pull Down Menus, the Tool Bar and the Status Bar.
  • Page 11: Configuring The Units Using Catvisor Commander

    Configuring the units using CATVisor Commander By clicking a device, the Configuration Display will show its configuration display pages. Each element has its own type of configuration display pages, which include all controls and settings that can be configured or monitored. The Configuration Display consists of several pages;...
  • Page 12 When you have entered a new setting, the Apply button is activated. By clicking this button you verify the new settings and they will be sent to the unit. If these settings are legal, they become valid immediately and the Apply button turns inactive. By clicking Cancel you can restore the original settings.
  • Page 13: Dvp432 Configuration Display

    DVP432 Configuration Display General Commander's Configuration Display consists of several pages. Only one page is completely visible at one time. Other pages are visible as tabs. You can activate a page simply by clicking the tab's heading. A DVP432 has the following Configuration Display pages that are introduced in this document: •...
  • Page 14: Status Page

    Status Page The Status Page lists information messages about the status of the DVP432. These messages can be alarms, warnings or notifications. CATVisor Commander uses Status Flags to represent these messages. A flag indicates an alarm, a flag is the symbol for a warning and for a yellow blue...
  • Page 15 Alarms If an alarm is detected, the front panel “MODULE” -indicator shows and a red flag is in view beside the unit in Commander's Element Directory Window. Warning If a warning is active a yellow flag is displayed beside the unit in Commander's Element Directory Window.
  • Page 16: Current Values Page

    Current Values Page Measured values at Voltage [V] the moment Displays the actual voltages drawn at the moment. The specified output voltages and currents per circuit are 25V / 8 A, 12.5V / 5A and 6.3V / 10A. The voltages can be fine tuned using the spin buttons and the value relative to the tuning range can be seen at the blue bar under the voltage in question.
  • Page 17 Power Displays the relative power output in relation of the total capacity of the voltage outputs. Note that the 12.5V and 6.3V outputs use the 25V circuit so the load on them is also shown in the 25 V line. Temperature The bar displays the relative PSU temperature.
  • Page 18: Min & Max Page

    Min & Max Page Measured maximum Voltage [V] and minimum values Displays the measured minimum and maximum voltages since the last reset. Reset the minimum and maximum values by pressing the “Reset MinMax” -button. Current [A] Displays the measured minimum and maximum currents since the last reset.
  • Page 19: The Fans Page

    The Fans Page Fan Control Fan control The unit has default setting of automatic ("Auto") fan control. The use of the automatic control is recommended. Selecting "On" and pressing "Apply" forces the fans to ventilate at the maximum speed all the time. Start Temperature When the Fan Control is enabled the user can set ("Auto") the Start Temperature (the temperature when the fans start to...
  • Page 20: The Properties Page

    The Properties Page Displays the unit hardware/ software information. The unit can be named with an alias name, which will be displayed in the Element Directory Window. DVP432 Configuration Display • 19 DVP432 User Manual, 59300088, rev004...
  • Page 21: Legal Declarations

    Information in this document is subject to change without notice and does not represent a commitment on the part of Teleste Corporation. The software as described in this document is supplied only under a licence agreement. The software may be used or copied only in accordance with the terms of the agreement.
  • Page 22 Notes • 21 DVP432 User Manual, 59300088, rev004...
  • Page 23 Notes • 22 DVP432 User Manual, 59300088, rev004...