IDEAL Concord CXDi 110 User Manual

Advertisement

Quick Links

USERS
G U I D E
Concord
CXDi 110/H-180/H

Advertisement

Table of Contents
loading

Summary of Contents for IDEAL Concord CXDi 110

  • Page 1 USERS G U I D E Concord CXDi 110/H-180/H...
  • Page 2: Commissioning Instructions

    Current Gas Safety (Installation and Use) WARNING. Regulations or rules in force impose certain This appliance MUST be efficiently earthed. statutory obligations on gas users. This appliance must be installed by a CORGI registered installer. This appliance must not be subject to incorrect use: It is ESSENTIAL that the instructions in this booklet WARNING.
  • Page 3: To Shut Down The Boiler

    3 FEATURES OF THE CONTROL SYSTEM - continued PUMP OVERRUN SERVICING INSTRUCTIONS If the flow temperature is above 75 C at the time of boiler These are provided to assist the service engineer. shutdown, the controls will maintain pump operation until FAULT DIAGNOSIS the residual heat within the appliance has been dispersed and the flow temp is below 75...
  • Page 4 6 USING THE BOILER FEATURES AND CONTROLS The diagram below shows the sequence of steps to be taken when reading the instructions on the following pages. Concord CXDi/H - Users...
  • Page 5 7 USING THE BOILER FEATURES AND CONTROLS - continued ON / STANDBY [1/0] BUTTON Turns the boiler ON and to STANDBY. WARNING If the weather compensation option is fitted then a further STANDBY does NOT electrically isolate the boiler. screen will be displayed after commissioning. When this switch is in the STANDBY position the display will The [UP] button will access the above options in reverse.
  • Page 6: Set Time & Date

    8 USING THE BOILER FEATURES AND CONTROLS - continued SET TIME/DATE This will cause the hours to flash and if the correct ON time Enables the correct time and date to be entered. has been entered the [EXIT] button should be pressed. The display will now show the OFF for time zone one.
  • Page 7: Maintenance

    9 USING THE BOILER FEATURES AND CONTROLS - continued Delayed High Rate Gas valve Operation When the boiler is started from cold the high rate gas valve will be delayed for 3 minutes and then energised. If the boiler flow temperature is equal to or greater than 55 C then this delay will NOT occur.
  • Page 8 Ideal Boilers, P.O. Box 103, National Ave, Kingston upon Hull, HU5 4JN. Telephone: 01482 492 251 Fax: 01482 448 858. Registration No. London 322 137. Caradon Ideal Limited pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice.

Table of Contents