Diagnostics And Monitoring - BFT VISTA SL Installation And User Manual

Automation doors
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 19
Press the OK key
Control unit software version
N. total manoeuvres (x 1000)
N. manoeuvres since latest maintenance (x 1000)
N. radio control devices memorised
OK
- +
OK
- +
OK
- +
OK
- +
OK
Opening
G
A
B
Fig. C1
+/-
OK
OK
C
E
See PARAMETERS MENU
See LOGIC MENU
See RADIO MENU
OK

DIAGNOSTICS AND MONITORING

DIAGNOSTICS
DESCRIPTION
CODE
STOP input activated
stop
Open-key input activated
ey
INTERNAL RADAR input activated
intr
EXTERNAL RADAR input activated
extr
EXTERNAL RADAR input activated
opph
CLOSING PHOTOCELL input activated
clph
EMERGENCY input activated
e er
Obstacle detected
a p
Error in safety device test during opening
Er01
Error in safety device test during closing
Er02
/
Er19 Problems detected in motor's control circuit
Er11
Encoder disconnected or faulty
Er21
Error in communication with devices connected to RS485 serial line.
Er51
Error in communication between automatic doors in cage mode.
Er53
autoset function is running. WARNING! Obstacle detection
set
function is not active
C2
F
Scroll up
Scroll down
Confirm/Switch on display
Exit Menù
Closing
H
B
A
D
VISTA SL
- 25

Advertisement

Table of Contents
loading

Table of Contents