Electrical Supply; Warning! This Appliance Must Be Earthed - Dimplex R7 Installation Instructions Manual

Electricaire warm air heating system
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS
PREPARATION
The heater will arrive separately from its storage
bricks, the following bricks will be required.
R 7 / 8 / 10
-
R12
-
R15
-

Electrical Supply

Two supplies are required for the operation of this heater -
for 'on-peak' and 'off-peak' supply. Both supplies should be
connected through isolator switches. A time clock / thermostat
control circuit may be required.
WARNING - This appliance
must be earthed
Only heat resisting cable (min. rating T85) should be used.
40 bricks
48 bricks
64 bricks
POSITIONING
Important - In every case the unit must be fi tted on top of a
plenum chamber for correct operation.
The unit can be installed free standing or in a suitable cupboard.
For minimum clearances all around the heater refer to Fig. E. The
fl oor must be checked to ensure that it is capable of bearing the
weight of the unit, see warning on front cover. Also the fl oor should
be fl at and level. A concrete plinth measuring 700x700mm can be
constructed. The plenum should be insulated from the fl oor or plinth
by at least 13mm of non-compressible insulation material.