Niran Rai
April 28, 2025
How do I connect the this modem for the remote accessibility ?
1 comments:
Mr. Anderson
May 15, 2025
To connect the ASC ASC300LW modem for remote accessibility:
1. Use either an RS-485 (4-wire) or RS-232 (2-wire) serial interface. 2. Set the serial communication protocol to 2400 Baud, No parity, 8 data bits, 1 stop bit (2400,N,8,1). 3. Assign a hexadecimal address (1 to F) to the unit: - Press and hold the LOC/REM button. - Press and release the RESET button to toggle to REM mode (REM will display on the screen). - Use the UP or DOWN buttons to select the desired address (1 to F). 4. Communicate with the unit using its assigned hex address.
This answer is automatically generated
Summary of Contents for ASC ASC300LW
Page 1
Model ASC300LW Beacon Receiver Instruction Manual Rev. 351-4-0111 www.atlanticsat.com www.beaconreceiver.net Atlantic Satellite Corporation 259 Expressway Court Virginia Beach, Virginia 23462 Phone: 757-318-3500 Fax: 757-318-7020 sales@atlanticsat.com engineering@atlanticsat.com _____________________________________________________________________ ATLANTIC SATELLITE CORPORATION MODEL ASC300LW BEACON RECEIVER...
Front Panel Facilities Local Operation 3.11 Changing Frequency 3.12 Changing Gain Display Rear Panel Facilities Serial Communications Using the ASC Simple User Interface Program Warning Notice Warranty Repair Service Policy 10.0 CE Declaration of Conformity 11.0 Continuous Digital Streaming (OPTIONAL) _____________________________________________________________________...
Beacon Receiver 1.0 Functional Description The Model ASC300LW Beacon Receiver is a high performance unit that is designed to real time track the power density of a satellite beacon and output a DC voltage that is linearly proportional to the beacon power. The applications for the ASC300LW are for antenna step track controlling and uplink power control systems.
The attenuation is displayed in dB from 0 to 60 dB on 0.5 dB steps. _____________________________________________________________________ ATLANTIC SATELLITE CORPORATION MODEL ASC300LW BEACON RECEIVER...
LOCK front panel LED will not be lighted. The signal strength voltage is displayed in volts DC. The range that is displayed is 0.00 to +9.99 VDC. The normal optimum operating level is +7.50 VDC. _____________________________________________________________________ ATLANTIC SATELLITE CORPORATION MODEL ASC300LW BEACON RECEIVER...
0.5 V/dB over a 20 dB input signal change. S2: LNB Voltage, +18 VDC, 500 ma, max., Switchable In/Out on input connector center conductor. AC RECEPTACLE: 90-264 VAC, 47-63 Hz Input, auto-sensing. Spare fuse compartment within receptacle.\ _____________________________________________________________________ ATLANTIC SATELLITE CORPORATION MODEL ASC300LW BEACON RECEIVER...
Page 7
J5: INPUT The frequency input range is 930 to 2300 MHz with an input level range of –30 to –90 dBm per beacon carrier. J5 Input: Type-F Female 75 ohm J6 Input: 50 ohm, N-type, female connector, Optional J7 Input: (SMA optional) _____________________________________________________________________ ATLANTIC SATELLITE CORPORATION MODEL ASC300LW BEACON RECEIVER...
If an alarm condition exits, the unit is out of lock, and then the signal strength voltage will not be displayed and will be displaced with the word ALARM. To change parameters of the unit transmit the following command string: _____________________________________________________________________ ATLANTIC SATELLITE CORPORATION MODEL ASC300LW BEACON RECEIVER...
Page 9
To poll the unit to see if the changes have been made transmit the following sequence; 0<space>0<space>0<space> All other commands are the same as described above with the exception that the address character does not need to proceed the command structure. _____________________________________________________________________ ATLANTIC SATELLITE CORPORATION MODEL ASC300LW BEACON RECEIVER...
Shown below are various screens that have been preset for communicating with the unit. When you initially open the ASC Beacon Receiver Control Program, the above screen will appear. Click on Configure and the following screen will appear.
Page 11
On the Model pull down screen select the model that you will be working with. In this case you will see that the model ASC300LW has been selected. You will also see that the baud rate has been set at 2400 and the Address has been set to F. Note all other ASC300 series beacon receiver baud rates should be set to 2400.
Page 12
0.0 to 60.0 on 0.5 dB steps. It is recommended that the unit be initially set at an attenuation of 20.0 dB. Click OK and the selected parameters will be transmitted to the unit and the following screen will appear. _____________________________________________________________________ ATLANTIC SATELLITE CORPORATION MODEL ASC300LW BEACON RECEIVER...
Page 13
POLL button on the previous screen or can be selected to automatically poll by selecting Automatic. In the Automatic mode the polling time in milliseconds can be set by the user. Do not use a polling rate of less than 300 milliseconds. _____________________________________________________________________ ATLANTIC SATELLITE CORPORATION MODEL ASC300LW BEACON RECEIVER...
Page 14
The trailing characters ^J^M are the control characters for line feed and carriage return. The signal strength is separately displayed after the line Signal strength: This completes the set up of the ASC Beacon Receiver Control Program. _____________________________________________________________________ ATLANTIC SATELLITE CORPORATION...
Page 15
7.0 Notice: This publication and its contents are proprietary to Atlantic Satellite Corporation or ASC and intended solely for the contractual use of its customers for no other purpose than to install and operate the equipment described herein. This publication and its contents shall...
2. Products, items, parts, accessories, subassemblies, or components which are expendable in normal use or are of limited life, such as but not limited to, bulbs, fuses, lamps, glassware, etc. ASC reserves the right to revise the foregoing list of what is covered under this warranty.
Before a warranty repair can be accomplished, a Repair Authorization must be received. It is at this time that ASC will authorize the product or part to be returned to the ASC facility or if field repair will be accomplished. The Repair Authorization may be requested in writing, email or by calling: Atlantic Satellite Corp.
As an example, for signal strength of 7.50 Volts and the unit locked the data string would be: #1 750 If the unit is not locked the data string would be: #0 0 _____________________________________________________________________ ATLANTIC SATELLITE CORPORATION MODEL ASC300LW BEACON RECEIVER...
Need help?
Do you have a question about the ASC300LW and is the answer not in the manual?
Questions and answers
How do I connect the this modem for the remote accessibility ?
To connect the ASC ASC300LW modem for remote accessibility:
1. Use either an RS-485 (4-wire) or RS-232 (2-wire) serial interface.
2. Set the serial communication protocol to 2400 Baud, No parity, 8 data bits, 1 stop bit (2400,N,8,1).
3. Assign a hexadecimal address (1 to F) to the unit:
- Press and hold the LOC/REM button.
- Press and release the RESET button to toggle to REM mode (REM will display on the screen).
- Use the UP or DOWN buttons to select the desired address (1 to F).
4. Communicate with the unit using its assigned hex address.
This answer is automatically generated