Start-Up Procedure - Philips AX3217 Service Manual

Portable compact disc player
Hide thumbs Also See for AX3217:
Table of Contents

Advertisement

START-UP PROCEDURE -CHART
POWER OFF
(stand-by)
N
PLAY
pressed ?
Y
DC/DC converter
is switched on
µP resets
CD10&NPC
PORES=L
NPC_RES=L
µP initializes
CD10&NPC
with default
parameter/settings
µP sends
command to CD10:
"move slide inside"
inner switch
N
closed within
~6s ?
Y
µP sends
command to CD10:
"move slide outside"
inner switch
N
open within
~0.3s ?
Y
µP sends
commands to CD10:
"slide servo off"
µP sends
commands to CD10:
"laser on"
"focus servo on"
µP accelerates
disc motor for
~200ms
Start-up procedure for external DC supply,
no accu inserted, hold-switch in off pos.,
ESA on, resume-mode off, CD-door closed.
re-initialize CD10
and restart focus
search procedure
re-initialize CD10
and restart focus
search procedure
radial
error handler
subcode
error handler
3 - 6
focus found
N
during ramping
cycle ?
Y
µP calculates
ramping offset and
sends play-params
to CD10
focus
N
stability test
ok ?
Y
µP accelerates
disc to nom. speed
N
disc at nom.
speed within
~10s ?
Y
µP initializes
radial servo loop
(~330ms)
µP releases
muting
(via MUTE)
µP sends command
to CD10: "jump
10 tracks inside"
N
jump
ok ?
Y
N
subcode
ok ?
Y
TOC
N
found within
~30s ?
Y
display shows
"nF d1SC"
PLAY-MODE
start-up stopped
µP sends new focus
parameters to CD10
(switch to higher
focus sensitivity)
focus found
Y
during ramping
cycle ?
N
already
looped through
N
all (4) focus
sensitivities
?
Y
switch back to
normal focus
sensitivity
focus found
Y
during ramping
cycle ?
N
µP sends new focus
parameters to CD10
(switch to higher
focus sensitivity)
focus found
Y
during ramping
cycle ?
N
already
looped through
N
all (4) focus
sensitivities
?
Y
display shows
"no d1SC"
start-up stopped

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ax3221Ax3222Ax3223Ax3224Ax3219

Table of Contents