Worcester 50/70 Installation And Servicing Instructions page 14

Floor standing oil-fired pressure jet appliances
Table of Contents

Advertisement

Fig. 13. Electro Oil Inter B9 Burner.
(50/70 Model).
Combustion Head
A
2 mm
10 mm
Draught tube
Nozzle
Output
Combustion
kW
Head
15
PL 6/7/21.5/10 x 78 mm
17
PL 6/7/21.5/10 x 78 mm
19
PL 6/7/21.5/10 x 78 mm
To adjust the nozzle position,
undo the locking screw located
at the rear of the nozzle line and
rotate the adjusting disc one
turn anti-clockwise to move
forward by 1 mm.
Fig. 14. Electro Oil Inter B11 Burner.
(70/90 Model).
Combustion Head
A
10 mm
Draught tube
Nozzle
Output
Combustion Head
kW
20-25
PL 10/4/24/10 x 78 mm
Spark gap
2.0 - 2.5 mm
Photocell
Adjusting
disc
Nozzle block
Pressure
adjustment
screw
Dimension
A
3 mm
5 mm
5 mm
Oil pump
Air control indicator
Air adjustment screw
(4 mm hexagonal head)
Spark gap
2 mm
3-3.5 mm
Photocell
Nozzle block
Dimension
A
5 mm
Locking screw
Air adjustment screw
(4mm hexagonal head)
Air control indicator
14
Combustion head
Lockout reset button
Pressure
Lockout
gauge port
reset button
Control box
Pressure
Oil pump
adjustment
screw
Transformer
Control box
Transformer

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

70/9090/110

Table of Contents