Installation Checklist - American Standard HPWH50G-AS Owners And Operation Manual

Residential electric heat pump water heater
Table of Contents

Advertisement

HEAT PUMP WATER HEATER

INSTALLATION CHECKLIST

1. Tank location:
1) Check if room size less than 10' x 10' x 7' (700 cu. ft.). If yes, louvered doors or similar ventilation
is required.
2) Ensure that back of unit is at least 7 inches away from wall or other obstacles.
Plumbing connections:
2.
1) Ensure that connections DO NOT prevent air filter removal.
2) Ensure there are no leaks after filling the tank with water, either when water is flowing or not.
Condensate lines are in place:
3.
1) Short tube connected to upper drain nozzle.
2) Longer tube on lower drain nozzle connected and directed into a floor drain or a condensate pump.
3) Temperature & Pressure-Relief Valve are functioning and drain line completed per local code.
4) Electrical connections DO NOT prevent air filter removal.
5) Verify that control panel displays 120°F Auto mode.
6) Front cover is in place.
WHAT TO EXPECT FOR "NORMAL START-UP"
Only after the unit has been installed and the electrical & water connections are secure and checked, should the unit
be filled with water (The tank is vented by opening any hot water faucet in the location to permit the tank to fill
completely with water). Once tank is filled with water and electricity is connected, the user must press the POWER
button on the user display interface. The unit will then remind the user to check that the tank has been filled with
water; which is acknowledged by pressing POWER again.
Elapsed Time
0 to 1.5 minutes
1.5 to 3 minutes
8 to 30 minutes
Element turns on for about 20 minutes
30 minutes and
beyond
NOTE: The heat pump operating ranges are from 45°F to 120°F. If the ambient temperature is
outside of this range, the heat pump will not be able to run and the backup electric elements will be
used until the ambient temperature returns to the normal operating range.
22
HPWH50G-AS Actions
Unit is silent
Fans turn on
Compressor turns off and upper
Upper element turns off and
compressor turns back on
Comments
This 3 minute off-time prevents compressor damage.
To quickly provide initial amount of hot water for
user (about 25 gallons).
User efficient heat pump for majority of heating.