  • Page 1 SKAMOTEC 225 FIREPLACE BUILDING BOARD INSTALLATION MANUAL...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION..............................3 Assembling fireplace platform (structure) .................... 3 Attaching fireplace platform (top) ......................3 Positioning fireplace & secure in place ....................4 Installing blocking ..........................4 4.1 Construction of sidewalls ........................4 Installing side panels..........................5 Installing 2 front bottom panels ......................6 6.1 Lap joint panel .............................
  • Page 3: Installation

    Ventilation should be made according to the specific stove spec. with air intake at the bottom and air outtake at the top. Be sure to keep a 3 - 5mm distance between the heath source and Skamotec 225. 1. Assembling fireplace platform (structure) Use screws (e.g.
  • Page 4: Positioning Fireplace & Secure In Place

    Positioning fireplace & secure in place Make sure to place the fireplace level and square. Installing blocking Use 25 x 38 mm Blocking on floor and ceiling and use e.g. wood screws to fasten them to the floor and ceiling. 4.1 Construction of sidewalls Moisten the surfaces of the Skamotec boards with water and apply mortar cement to the joints in order to glue the...
  • Page 5: Installing Side Panels

    Ceiling: Place the Skamotec 225 against the blocking and fasten it by using both screws and mortar cement. Maintain a min. edge distance and spacing Floor: Step 1: Place the Skamotec 225 board against the blocking and fasten using both screws and mortar cement.
  • Page 6: Installing 2 Front Bottom Panels

    Maintain a minimum of 5 mm clearance all around to allow expansion of the board 6.2 Fastenening the 2 front bottom panels Locate the 2 Skamotec 225 boards against the blocking and the side panels. Use both screws and mortar cement to fasten the boards.
  • Page 7: Installing Front Top Panel

    7. Installing front top panel Fasten the Skamotec 225 board at the bottom and top against the blocking and side panels using both screws and mortar cement. NOTE: Maintain a minimum edge distance and spacing Please look at page 8 and 9 for further fastener details.
  • Page 8: Blocking

    BLOCKING Corner detail Side panel 25 mm” x38 mm Blocking Front panel Floor detail Front/Side panel 25 x 38 mm Blocking Floor Wall detail 25 x 38 mm Blocking Side panel Blocking detail (plan view) Existing 38 mm Typ. Fastener location 255 mmm (Maximum)
  • Page 9: Lap Joint Detail

    Lap joint detail Section view Front/Side Min. Front/Side panel Fastener detail Fastener location 255 mm 25 mm 25 mm (Maximum) Min. Min. Spacing 102 mm (Min.)
  • Page 10: Preassembling Side Panels

    Preassembling side panels Lap joint Desired 38 mm 25 x 38 mm Blocking Fasten using screws & mortar cement Maintain min. edge Lap joint Fasten using panel screws 102 mm & mortar cement min. Maintain min. edge distance & spacing...