Adjusting The Release Switch And The Metering Switch - Minolta XD-11 Repair Manual

Table of Contents

Advertisement

Figure 100
simulates the camera's timing circuit at
the 1/1000-second setting. There are
several ways you can build such a timing
circuit. Fig. 100 illustrates one method.
You should have no trouble in obtaining
the components from any electronics
supplier.
Although you could build the power
supply into the test box, we've designed
the circuit of Fig. 100 to be used w ith a
separate 3V DC power supply. Notice
that the magnet lead connects to the col­
lector of a switching transistor. A com­
parator controls the signal at the tran­
sistor base. When the output of the com­
parator goes high, the transistor switches
on. The transistor then conducts current
through the shutter's electromagnet.
The trigger switch of the shutter con­
nects to the timing capacitor of the timing
circuit. W ith the shutter cocked, the closed
trigger switch shorts the timing capacitor to
ground. Then, when you release the shut­
ter, the trigger switch opens and allows the
timing capacitor to start charging.
When the timing capacitor reaches the
reference voltage, the comparator sw it­
ches states — the output goes low to
shut o ff the transistor. In turn, the tran­
sistor shuts o ff the current through the
shutter's
electromagnet.
we've provided a variable-resistor adjust­
ment to establish the reference voltage at
the noninverting input of the comparator.
Use the variable resistor to adjust the tim ­
ing circuit for 1/1000 second.
Figure 101
W e've also provided a second speed in
Fig. 100. As mentioned earlier, the slower
shutter-speed setting serves as an opera­
tional check. You may wish to set the
second speed fo r 1/100 second, the full-
aperture speed. That way, you can also
use the test box fo r checking X-sync
operation.
Rather than the comparator IC, you
may prefer to use a two-transistor switch
In Fig.
100,
as shown in the inset, Fig. 100. Connect
the base of the second transistor to the
timing capacitor. By using a variable
resistor to control the capacitor-charge
time, you can adjust the test circuit for
1/1000 second.
SWITCH
ADJUSTING THE RELEASE SWITCH
AND THE METERING SWITCH
There's another reason for removing
the shutter — to reach the release switch
S3 and the metering switch S5, Fig. 101.
Earlier, we described how you can check
the tw o switches w ithout disassembly.
However, if you pinpoint the problem to
one of the switches, lift aside the shutter
to make the repair (you d o n 't have to
disconnect the shutter wires to adjust and
clean the switches).
A sliding brush contact.
closes both switches as you depress the
release slide. The brush first connects the
green-wire land to ground, thereby clos­
Fig. 101,

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents